Degradation Mechanism and Reliability of Flip Chip Interconnects using Anisotropic Conductive Adhesives for High Current Density Packaging Applications

N/A
N/A
Protected

Academic year: 2023

Share "Degradation Mechanism and Reliability of Flip Chip Interconnects using Anisotropic Conductive Adhesives for High Current Density Packaging Applications"

Copied!
6
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Degradation Mechanism and Reliability of Flip Chip Interconnects using Anisotropic Conductive Adhesives for High Current Density Packaging Applications

Myung Jin Yim, Hyoung Joon Kim, Chang Kyu Chung and Kyung Wook Paik Dept. of Materials Science & Engineering, KAIST

373-1, Kusong-dong, Yusong-gu, Taejon 305-701, Korea

Tel.: +82-42-869-3375, Fax: +82-42-869-3310, E-mail: myungjin@kaist.ac.kr

Abstract

In this paper, we investigated the degradation mechanism and the reliability behaviors of flip chip joint using Anisotropic Conductive Adhesives (ACAs) and Au bumped chip under high current density. The current carrying capability and current stressing reliability of flip chip assembly using three different types of ACAs were performed to investigate the effect of thermal conductivity of ACA and the conductive particle type on the current carrying capability and current stressing reliability of ACA flip chip joints.

For the ACA materials, we prepared two conventional ACAs with different conductive fillers, which are thermally non-conductive, and one thermally conductive ACA. For the conductive fillers, we incorporated Au coated polymer balls and metallic Ni balls in 5 µm diameter. For the thermally conductive ACA materials, we incorporated thermally conductive fillers of silicon carbide with less than 1 µm diameter in the conventional ACA formulation. The thermal conductivity and thermo-mechanical properties of three ACAs such as thermal conductivity, cure behavior, coefficient of thermal expansion (CTE) were measured in comparison.

The current carrying capabilities and current stressing reliabilities of flip chip joints using ACAs with different conductive filler type, thermal conductivity and physical properties were investigated. The current carrying capability and electrical reliability of flip chip joints using enhanced thermally conductive ACAs were improved due to high thermal conductivity. The failure analysis including cross- section SEM works shows that the interface degradation and adhesive swelling are main degradation mechanism of the high current density interconnection of flip chip assembly using conventional ACA, in which high junction temperature enhance such thermally induced degradation mechanism. The improved current carrying capability and current stressing reliability of flip chip assembly using thermally conductive ACAs were due to reduced interface and adhesive degradation through easy heat dissipation of adhesive that bring slow down of thermally induced degradation mechanism. There were no degradations of ACA flip chip joints using Ni-filled ACA and Au-coated polymer-filled ACA up to 200 hrs under 3.0 A current stress.

1. Introduction

Flip chip technology is becoming attractive as new package solution and widely used to meet the ever-growing requirements of highly integrated, small form factor and high electrical performances. Furthermore, it is also more effective in dissipating the heat from IC to substrate or heat sink due to short thermal paths than conventional plastic mold package

[1]. Especially flip chip assembly using ACAs has been gaining much attention for its simple and lead-free processing as well as cost effective packaging method [2]~[4]. ACAs, mixtures of conductive particles in an insulating polymer matrix, provide electrically anisotropic conductivity due to the trapped conductive particles between conductive bumps on the flip chip and the corresponding pads on the substrate.

The continuing downscaling of structural profiles, increase in the interconnection density of flip chip packaging using non-solder bump and conductive adhesives has given rise to high current related failure problem. As the bump size and pitch are reduced, the current flow density at the interconnection is also increased. This high current density can cause failures of ACA flip chip joints due to interface degradation between non-solder bump and I/O pad metal due to intermetallic compound formation together with interface delamination, and adhesive swelling or degradation due to joule heating. The high junction temperature at the adhesive flip chip joint can enhance the thermally induced failure mechanism [5] and therefore, it is necessary for the ACA to be thermally conductive medium which allows effective heat dissipation from ACA flip chip joint through adhesive resin to the substrate for the flip chip package and improve the lifetime of ACA flip chip joint by reducing interface and adhesive degradation under high current density environment [6]. However, the detail degradation mechanism of ACA flip chip joints under high current density environment has not been investigated yet.

In this paper, we investigated the degradation mechanism and the reliability behaviors of flip chip joint using ACAs with different types of conductive filler and thermal conductivities under high current density. The current carrying capability and current stressing reliability of flip chip assembly using three different type of ACA were investigated.

2. Experiment

2-1. Material Preparation

The ACA were formulated by mixing fillers, liquid epoxy resin, hardener and other additives. The mixture was homogeneously stirred and degassed under vacuum environment to eliminate the air induced during stirring.

ACA-1 was the conventional ACA formulation with metallic Ni particles in 5 µm diameter at amount of 6 wt%. ACA-2 was the ACA with Au-coated polymer particles in 5 µm diameter at amount of 6wt%. ACA-3 was the thermally conductive ACA with Ni particles in 6wt% as conductive fillers and silicon carbide (SiC) fillers in 0.2 µm diameter is at the content of 100 part per hundred resin (phr). We fixed the

(2)

filler content of 100 phr in the formulation of thermally conductive ACA based on our previous results of thermal conductivity and viscosity [6]. For the binder system, it is formulated based on bisphenol F type liquid expoxies, and latent imidazole type curing agent. Surface modification of fillers was performed to get uniform dispersion of fillers inside epoxy matrix of ACA composite.

For the material characterization, we measured the thermal conductivity of cured ACAs composite materials, curing behavior and coefficient of thermal expansion (CTE). The thermal conductivity were measured by the laser flash method using LFA447 Nanoflash, NETZSCH company [7], and the sample size used for the laser flash method had 8×8×1 mm dimension with the mirror-like polished surface. The differential scanning calorimeter (DSC) was performed to investigate curing property of ACAs. The cured thermally conductive ACA sample were prepared by placing the adhesive mixture in a convection oven at 150 oC for 30 minutes and cutting with 0.6 mm thickness for thermo- mechanical analysis (TMA) test to measure the CTE values.

2-2. ACA Flip Chip Bonding Process

Test Si chip has peripheral-arrayed Al pads, and the pad pitch is 300 µm. There are two Au bumps on test chip. Au stud bumps were formed using K&S 4522 manual wire bonding machine and Au electroplated bumps were formed by Au plating and lithography process. Test substrate has patterned Cu/Ni/Au trace for measurement of contact resistance of each flip chip joint using ACAs. Table 1 summarized the specification of test samples used in flip chip assembly using three different kinds of ACAs in form of paste, ACP (Anisotropic Conductive Paste).

Table. 1 Specification of Test Samples Chip size X = 10 mm, Y = 10 mm

Bump mat’l Au bump (stud and electroplated) Bump height 60 µm (stud), 20 µm (electroplated) Bump size 85 µm (in diameter), 100 µm (in line) Test IC

Bump pitch 300 µm

Base film FR-4, 1 mm thick Substrate Conductor Cu/Ni/Au, 18 µm thick

ACP-1 Ni-filled ACA

ACP-2 Au-coated polymer ball-filled ACA ACAs

ACP-3 Ni-filled and thermally conductive ACA

For the ACA flip chip assembly bonding process, firstly, the gold bumps on the chip and the I/O pads on the test substrates were aligned. Then, ACAs materials were dispensed on the substrate using manual dispensing machine.

Finally, thermo-compression bonding was performed with bonding condition at bonding pressure of 100 MPa and temperature of 180 oC for 30 seconds. During ACA dispensing and bonding process, substrate heating at 80 oC is recommended for low viscosity of ACAs and concave fillet shape of cured adhesive. Thus the chip is electrically connected to the substrate via entrapped conductive fillers of

the ACA and direct mechanical contact of Au stud bump on the electrical pad of the substrate.

2-3. Current Carrying Capability and Current Stressing Reliability Test

For current carrying capability and current stressing reliability test, the special test equipment as shown in figure 1was designed to investigate I-V behavior and interpret current stress induced phenomena of flip chip interconnect using ACAs. For the determination of maximum allowable current, bias stressing was applied to a pair of Au bump and ACA joint. The current level at which current carrying capability is saturated is maximum allowable current. During the I-V test, applied voltage step is 0.1 V and duration time at each voltage level is 5 seconds. The maximum current limit of the test equipment, HP E3632A, is 7 A, and the test vehicles were placed on a flat surface at room temperature. The effect of thermal conductivity of ACAs and the type of conductive particle on the current carrying capability was investigated

Power supply Control unit

(I, V, t)

Specimen

Grips

Data Acquisition System (I, V, R, T) PC

Fig. 1. A schematic drawing of test equipment for current stressing test.

The current stressing reliability of ACA flip chip assembly was characterized. The effect of thermal conductivity of ACA and the conductive particle type on the current carrying capability under high current stress was studied by monitoring of ACA joint resistance. Cross-sectional SEM pictures after the completion of current stressing test were taken to investigate the failure mechanism of flip chip assembly under high current stressing condition.

3. Results and Discussion

3-1. Material Characterization 3-1-1. Thermal Conductivity of ACAs

Figure 2 shows the thermal conductivity, thermal diffusivity and specific heat of three different ACAs as a function of temperature. Figure 2(a) is for ACP-1, which is Ni-filled convention ACA showing maximum thermal conductivity of

(3)

20 40 60 80 100 120 140 160 180 200 220 240 0.10

0.12 0.14 0.16 0.18

0.25 0.30 0.35 0.40

1.2 1.4 1.6 1.8 2.0

Specific Heat; Cp (J/g/K)

Thermal Conductivity (W/mK)

Thermal Diffusity (mm2/s)

Temperature (oC) ACP-1

(a)

20 40 60 80 100 120 140 160 180 200 220 240 0.10

0.12 0.14 0.16

0.20 0.25 0.30 0.35

1.2 1.4 1.6 1.8 2.0 2.2

Specific Heat; Cp (J/g/K)

Thermal Conductivity (W/mK)

Thermal Diffusity (mm2 /s)

Temperature (oC) ACP-2

(b)

20 40 60 80 100 120 140 160 180 200 220 240 0.24

0.26 0.28 0.30 0.32 0.34 0.36

0.55 0.60 0.65 0.70 0.75

0.8 1.0 1.2 1.4 1.6

Specific Heat; Cp (J/g/K)

Thermal Conductivity (W/mK)

Thermal Diffusity (mm2 /s)

Temperature (oC) ACP-3

(c)

Fig. 2 Thermal conductivity behaviors of ACAs as a function of temperature for three ACA materials; (a) Ni-filled ACA, (b) Au-coated polymer ball-filled ACA and (c) Ni-filled and thermally conductive ACA.

0.36 W/m·K at 125 oC. Figure 2(b) and 2(c) shows the thermal conductivities of ACP-2 and ACP-3 are 0.32 W/m·K and 0.70 W/m·K, respectively. The high thermal conductivity of ACP-3 is due to the incorporation of thermally conductive fillers together with the conductive particles in ACA formulation. There are little influence of conductive particle

type on the thermal conductivity of ACA composite as shown in Fig. 2(a) and 2(b). Interesting observation is that all three ACAs exhibit the increasing thermal conductivity, maximum value around 125 oC and decreasing with increasing temperature. This is due to the changing thermal diffusivity and specific heat of three ACAs materials with increasing temperature. Since the heat capacity generally increases and the thermal diffusivity decreases with increasing temperature, therefore, the thermal conductivity is strongly dependent on temperature. The high thermal conductivity at peak temperature is effective to dissipate the heat from the hot spot at the flip chip joints using adhesive.

40 60 80 100 120 140 160 180 200

Heat flow (arb. unit) Endo up

Temperature (oC) Dynamic Scan (10 oC/min)

ACP-1 ACP-2 ACP-3

(a)

40 60 80 100 120 140 160 180

-0.005 0.000 0.005 0.010 0.015 0.020 0.025 0.030 0.035 0.040 0.045 0.050

Dimensional change (L/L0)

Temperature (oC) ACP-1

ACP-2 ACP-3

(b)

Fig. 3 (a) Curing behaviors of three ACAs and (b) dimensional change curves for three ACAs with increasing temperature for predicting CTE values.

3-1-2. Curing Property and CTE values of ACAs

Figure 3(a) shows temperature scan curves of three ACAs.

The curing reaction was started when temperature reached around 105 ~ 110 oC and has peak temperature of 120 ~ 125

oC, those are typical temperatures of conventional ACA.

From the curves in figure 3(b), the CTE values for each ACA material can be predicted. ACP-3 with thermally conductive fillers shows the lowest CTE values, which is desired

(4)

properties for highly reliable flip chip on organic substrate assembly. ACP-1 with Au-coated polymer balls shows largest CTE values.

3-2.Current Stressing Reliability of ACA Flip Chip Joint 3-2-1.Effects of ACA Thermal Conductivity on Current Carrying Capability and Current Stressing Reliability of ACA Flip Chip Joint

The effect of thermal conductivity of ACA on the current carrying capability of flip chip joints was investigated as in our previous study [6]. Figure 4 shows comparison result of I- V characteristics of ACA flip chip joints using two different ACAs. The flip chip joint using ACA-1 shows the typical I-V curve with maximum allowable current level of 4.53 A.

0.0 0.5 1.0 1.5 2.0

0 2 4 6 8 10

PCB Cu trace burning Conventional ACP-1

Thermally Conductive ACP-3

Current (A)

Applied voltage (V)

Fig. 4. I-V test (bias stressing) results at Au stud bumps/flip chip joints by conventional ACA and thermally conductive ACA.

0 20 40 60 80 100

0 20 40 60 80 100

Conventional ACP-1 Thermally Conductive ACP-3

Contact Resistance (m)

Time (hrs)

Fig. 5. Contact resistance changes of Au stud bump/flip chip joints using conventional ACA and thermally conductive ACA after 20, 40, 60, 100 hours under current stressing.

Contrarily, flip chip joint using thermally conductive ACA, ACA-3 shows almost linear increase of current as increase of voltage and maximum allowable current level is 6.71 A.

Therefore the current carrying capability of ACA flip chip joint was improved by the use of thermally conductive ACA for Au stud bumped flip chip assembly.

Figure 5 shows the resistance changes of flip chip joints using conventional ACA and thermally conductive ACA as a function of time under constant current of 4.1 A. The contact resistance value of upward electron flow (from PCB pads to chip pads) applied bumps (UEB) was measured. The contact resistance of conventional ACA flip chip joints increased abruptly as time passed 50 hrs and had open circuits before 100 hrs. But the thermally conductive ACA flip chip joints showed stable contact resistance behaviors without any open circuit.

The failure or degradation mechanism of ACA flip chip joints under current biasing test are suggested as follows; (1) Au-Al IMCs formation, (2) Crack formation and propagation along the Au/IMC interface, and (3) Al or Au depletion due to electromigration [8]. Figure 6 shows the cross-section SEM picture of the electrically failed ACA joint after current stressing reliability test. There are crack between Au stud bump and IMC interface and decomposition of polymer resin around Au bump.

Si chip Crack formation

Polymer degradation Au stud bump

Si chip Crack formation

Polymer degradation Au stud bump

Fig. 6. Cross sectional SEM pictures at Au stud bumps joints by conventional ACA after current stressing reliability test.

All those mechanisms of electrical degradation of ACA flip chip joints are caused by heat accumulation at the Au stud bumps/PCB pads and thermal degradation of adhesive due to joule heating under high current bias. If the local temperature of flip chip joint by ACA/Au stud bump is relatively low due to effective heat dissipation throughout thermally conductive ACA, the thermally degradation process due to local joule heating and thermal degradation are slowed down, and the stability of electrical joint can be obtained.

This effect was confirmed by the behavior of junction temperature on the surface of flip chip IC assemblies under current stressing condition as a function of current stressing time by thermal image analysis as shown in figure 7. The chip surface temperature increases abruptly and become stable at around 50 seconds of current stressing time. The chip surface using thermally conductive ACP-3 joint became hot faster than conventional ACP-1 joint, which means thermally conductive adhesive dissipates the heat from the source more easily than conventional ACA does. The maximum

(5)

temperature of chip surface of flip chip joint using thermally conductive ACP-3 is 10 oC lower than that of conventional ACP-1 under constant current stressing. Therefore, thermally induced degradation of flip chip joint using ACA was prohibited or slowed down by using ACA with improved thermal conductivity.

0 100 200 300 400 500

100 120 140 160 180

Conventional ACP-1 Thermally Conductive ACP-3

Chip Surface Temperature (o C)

Time (seconds)

Fig. 7 Chip surface temperature of flip chip assemblies using conventional and thermally conductive ACAs as a function of current stressing time.

3-2-2.Effects of Conductive Particle in ACA on Current Carrying Capability and Current Stressing Reliability of ACA Flip Chip Joint

The effect of conductive particle in ACA on the current carrying capability and current stressing reliability of flip chip joints was investigated. Figure 8 shows comparison result of I-V characteristics of ACA flip chip joints using two different conductive particles. Both flip chip joint using ACP-1 with Ni particle and ACP-2 with Au coated polymer particle shows the same I-V curve with maximum allowable current level of 3.62 A. This is because the ACA joints have similar number of conductive particles in the flip chip joints and have same thermal conductivity without any thermally conductive filler.

The initial contact resistances for both ACA flip chip joints are also similar. This can results in similar current carrying capability of ACA joints under the same surrounding polymer resin because the current carrying capability of ACA joints is related to the variation of the resistance of ACA joints [9].

Figure 9 shows the resistance changes of flip chip joints using Ni-filled ACA and Au-coated polymer-filled ACA as a function of time under constant current of 3.0 A. We reduced the applying constant current compared with the current stress level in the flip chip assembly using Au stud bump and ACA considering their I-V curves and current carrying capabilities.

The contact resistances of ACP-1 with Ni particle and ACP-2 with Au-coated polymer particle shows almost constant values up to 200 hours of applying current stressing.

Figure 10 shows the cross-sectional SEM pictures of Au plated bump joints using ACA with Ni particles and Au- coated polymer particles. We found that the contacts of both Ni particle in ACP-1 and Au coated polymer particles in ACP

0.0 0.5 1.0 1.5 2.0

0 2 4 6 8 10

Current (A)

Applied Voltage (V) ACP 1 with Ni-filler

ACP 2 with Au-coated polymer filler

Fig. 8. I-V test results at Au plated bumps/flip chip joints by Ni-filled ACA and Au-coated polymer-filled ACA.

0 50 100 150 200

0 20 40 60

Ni-filled ACP-1

Au-coated polymer-filled ACP-2

Contact Resistance (m)

Time (hrs)

Fig. 9. Contact resistance changes of Au plated bump/flip chip joints Ni-filled ACA and Au-coated polymer-filled ACA after 20, 40, 60, 80, 100 and 200 hours under current stressing.

-2 between Ni particles, Au plated bump and substrate electrode are stable even after 200 hrs current stressing of 3.0 A. Also there were no delamination between adhesive resin and Au bump, and no intermetallic compound formation between Al I/O and Au bump. These are presumably due to relatively low joule heating at ACA joints between Au plated bump, ACA and substrate electrode with the applying current of 3.0 A. The reliability of ACA flip chip joints at high current density depends on the level of stress current [5].

High stress current induces the high joule heating, which increases the junction temperature. High junction temperature accelerates the failure mechanism like intermetallic formation, crack growth and adhesive swelling. Therefore, when the stress current is lower than the current carrying capability, the lifetime of ACA flip chip joints increases. The possible reason for no failure at ACA flip chip joints using Au plated bump up to 200 hrs is low stress current and junction temperature. It is required to increase the current stress for the

(6)

Si chip Au plated bump

Ni particle

Cu electrode Si chip

Au plated bump

Ni particle

Cu electrode

(a) Si chip

Au plated bump Au plated polymer particle

Cu electrode Si chip

Au plated bump Au plated polymer particle

Cu electrode

(b)

Fig. 10 Cross-sectional SEM pictures at Au plated bump/flip chip joints by (a) conventional ACA with Ni-filler and (b) conventional ACA with Au-coated polymer filler after current stressing reliability test.

further study on the failure mechanism of ACA flip chip joints using Au plated bump.

Conclusions

The degradation mechanism and the reliability of flip chip joints using ACAs and Au bumped chip under high current density. The current carrying capability and current stressing reliability of flip chip assembly using three different types of ACAs were performed to investigate the effect of thermal conductivity of ACA and the conductive particle type on the current carrying capability and current stressing reliability of ACA flip chip joints.

The thermal conductivity of ACA has significant effects on the current carrying capability and resultant current stressing reliability of flip chip joints using ACAs. ACA flip chip joints with Au stud bump and conventional ACA showed unstable reliability under current stressing condition. The failure analysis shows that the interface degradation and adhesive swelling are main degradation mechanism of the high current density interconnection of flip chip assembly using conventional ACA, in which high junction temperature enhance such thermally induced degradation mechanism. The current carrying capability and electrical reliability of flip

chip joints using enhanced thermally conductive ACAs were improved due to reduction in failure mechanisms such as intermetallic compound layer and crack growth, and polymer degradation by lowering junction temperature.

The effect of conductive particle in ACA on the current carrying capability and reliability of ACA flip chip joints using Au plated bump under high current density was investigated. It was found that there was no electrical degradation of ACA flip chip joints up to 200 hrs under 3.0 A with current carrying capability of 3.6 A for both Ni-filled ACA and Au coated polymer-filled ACA. This is presumably due to low stressing current and low junction temperature.

The effect of Au plated bump with Al I/O pad on the formation of intermetallic compound layer should be investigated.

References

1. F. Takamura et al., “Low-thermal-resistance Flip-Chip Fine Package for 1-W Voltage Regulator IC”, In Proc.

IEEE/CPMT Int’l Electronics Manufacturing Technology Symposium, pp. 305~310, 2000

2. A. Torri, M. Takizawa, K. Sasahara, “ Development of Flip Chip Bonding Technology using Anisotropic Conductive Film”, in Proc. 9th International Microelectronics Conference, pp. 324 ~ 327, 1996

3. D. J. Williams et al., “Anisotropic Conductive Adhesives for Electronic Interconnection”, Soldering & Surface Mount Technology, pp. 4 ~ 8, 1993

4. J. Liu, A. Tolvgard, J. Malmodin, and Z. Lai, “ A Reliable and Environmentally Friendly Packaging Technology-Flip Chip Joining Using Anisotropically Conductive Adhesive”, IEEE Trans. Comp. Packag., Manufact.

Technol. Vol. 22, No. 2, pp.186~190, 1999

5. W. S. Kwon and K.W.Paik, “High Current Induced Failure of ACAs Flip Chip Joint”, in Proc. 52nd Electronic Components and Technology Conf., San Diego, CA.

pp.1130~1134, May 28~31, 2002

6. M. J. Yim, H. J. Kim and K.W.Paik, “Anisotropic Conductive Adhesives with Enhanced Thermal Conductivity for Flip Chip Applications”, J. of Elec.

Materials, Vol. 34, No.8, pp.1165~1171, 2005

7. W. S. Lee, I. Y. Han, J. Yu, S. J. Kim and T. Y. Lee,

“Thermal Characterization of Thermally Conductive Underfill for a Flip-Chip Package using Novel Temperature Sensing Technique”, In Proc. 6th Electronic Packaging Tech. Conf. (EPTC), pp.47~52, 2004

8. H. J. Kim, W. S. Kwon and K. W. Paik, “Effects of Electrical Current on the Failure Mechanisms of Au stud bumps/ACF Flip Chip Joints under High Current Stressing Condition”, in Proc. 5th Int’l Conference on Electronic Materials and Packaging, Singapore, pp. 203-208, Nov.

17-19, 2003

9. S. H. Fan and Y. C. Chan, “Current-Carrying Capacity of Anisotropic Conductive Film Joints for the Flip Chip on Flex Application”, J. Elec. Materials, Vol. 32, No.2, 2003

참조

관련 문서

First, the effect of the referee’s decision by area, number of volleyball games, and player’s career indicated that the fairness, consistency, and

This study has the purpose to investigate the applicability of different thickness aluminium alloys by friction stir welding to vehicle body and to

The purpose of this study was to compare the microleakage of different adhesive systems (three 2-step adhesives and two 1-step adhesives) in class V

This paper also analyzed the current status of the competitive power of 10 major ports in China using efficiency and SWOT analysis and sought the

Current Status and Prospect of Industrial Biotechnology Current Status and Prospect Current Status and Prospect.. of Industrial Biotechnology

The electrode potential and the surface concentrations of О and R are described by an equation of the Nernst form, regardless of the current flow. In effect, the potential

Effect of electric current on the microstructure and mechanical properties of hard-to-sinter materials with high melting point.. Effect of electric current on the

The similar current transient of a potential step to the RC circuit problem will be obtained for that of the IPE.. 1.2.4 Double-Layer Capacitance and Charging