Bio-process Lab

Fast Protein Liquid

Chromatography (FPLC )

(2)

Bio-process Lab

Column components

1. Packing

(3)

Bio-process Lab

Gel degassing.

(4)

Bio-process Lab

Stopping the outlet of the column.

(5)

Bio-process Lab

Filling liquid in the bottom of the column

(6)

Bio-process Lab

Pouring gell slurry to the column.

(7)

Bio-process Lab

Settling of gels.

(8)

Bio-process Lab

Adjusting the adaptor

(9)

Bio-process Lab

Fixed adaptor

(10)

Bio-process Lab

Conneting a line to the adaptor

(11)

Bio-process Lab

Adaptor touching

the upper layer of gels.

(12)

Bio-process Lab

Gel level lowers due to the solution flow

into the column.

(13)

Bio-process Lab

Stopping the outlet

line

(14)

Bio-process Lab

Connetion of pump

line to the adaptor

(15)

Bio-process Lab

Blue dextran solution flows in the column.

(16)

Bio-process Lab

2. Valve control

(17)

Bio-process Lab

Injection of sample

(18)

Bio-process Lab

FPLC controller.

3. Remote controller

(19)

Bio-process Lab

Pump front panel.

(20)

Bio-process Lab

Pump flow rate calibration

(21)

Bio-process Lab

Manual mode of gradient setting

(22)

Bio-process Lab

Valve number setting

(23)

Bio-process Lab

Flow rate setting

(24)

Bio-process Lab

Multimeter for digital data aquisition

4. Multimeter

(25)

Bio-process Lab

UV detector

5. Detector

(26)

Bio-process Lab

Software UV signal data aquisition

6. Software(PROTEK 506)

(27)

Bio-process Lab

Multimeter setting for sending data

to notebook computer

(28)

Bio-process Lab

Sampling time setup

(29)

Bio-process Lab

File name.

(30)

Bio-process Lab

Save data file In a folder

(31)

Bio-process Lab

Starting data acquisition End ing data collection

참조

관련 문서

O Interact with the customers and provides solution for the process issues of the assigned project or customer site. O Conduct machine process performance analysis,

Ross: As my lawfully wedded wife, in sickness and in health, until

각 브랜드의 강점과 약점이 서로 상충되는 경우, 각 브랜드에 있어서 어떤 속 성의 약점을 다른 속성의 강점에 의해 보완하여 전반적인 평가를 내리는 것.

 Two or more circuit elements are said to be in series if the identical current flows through each of the elements.. • The two resistors are in series, since the

• Internal flows are dominated by the influence of friction of the fluid throughout the flow field.. • In external flows, friction effects are limited to the boundary

다양한 번역 작품과 번역에 관한 책을 읽는 것은 단순히 다른 시대와 언어, 문화의 교류를 넘어 지구촌이 서로 이해하고 하나가

The index is calculated with the latest 5-year auction data of 400 selected Classic, Modern, and Contemporary Chinese painting artists from major auction houses..

• Concentration gradient of the oxidizing component, H 2 O 2 in the etch solution close to the surface and inside the thin surface oxide, during a wet chemical