INDUCTIVE SENSORS – 10-30V DC

N/A
N/A
Protected

Academic year: 2022

Share "INDUCTIVE SENSORS – 10-30V DC "

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

PROXIMITY SENSORS (MADE IN S. KOREA)

INDUCTIVE SENSORS – 10-30V DC

S. NO. OLD MODEL NEW MODEL SIZE

SENSING

RANGE PNP/ NPN

RESPONSE

FREQUENCY

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

HYP-8R-1.5PA HYP-8R-1.5NA

HYP-8R-2PA HYP-8R-2NA

HYP-12R-4PA HYP-12R-4NA

HYP-12R-2PA HYP-12R-2NA HYP-12R-2PC HYP-12R-2NC

HYP-18R-5PA HYP-18R-5NA HYP-18RL-5PA HYP-18RL-5NA HYP-18RL-5PC HYP-18RL-5NC

HYP-30R-15PA HYP-30RL-15NA

UP8RM-1.5PA UP8RM-1.5NA

UP8RD-2PA UP8RD-2NA

UP12RD-4PA UP12RD-4NA

UP12RM-2PA UP12RM-2NA UP12RM-2PC UP12RM-2NC

UP18RM-5PA UP18RM-5NA UP18RLM-5PA UP18RLM-5NA UP18RLM-5PC UP18RLM-5NC

UP30RD-15PA UP30RLD-15NA

8 MM 8 MM 8 MM 8 MM

12 MM 12 MM

12 MM 12 MM 12 MM 12 MM

18 MM 18 MM 18 MM 18 MM 18 MM 18 MM

30 MM 30 MM

1.5 MM 1.5 MM

2 MM 2 MM

4 MM 4 MM

2 MM 2 MM 2 MM 2 MM

5 MM 5 MM 5 MM 5 MM 5 MM 5 MM

15 MM 15 MM

PNP N.O NPN N.O

PNP N.O NPN N.O

PNP N.O NPN N.O

PNP N.O NPN N.O PNP N.C.

NPN N.C.

PNP N.O NPN N.O PNP N.O NPN N.O PNP N.C NPN N.C

PNP N.O NPN N.O

800 HZ 800 HZ

800 HZ 800 HZ

400 HZ 400 HZ

800 HZ 800 HZ 800 HZ 800 HZ

350 HZ 350 HZ 350 HZ 350 HZ 350 HZ 350 HZ

100 HZ 100 HZ

INDUCTIVE SENSORS – 90-240V AC

19.

20.

HYP-18RL-5AA HYP-30RL-15AA

UP18RLM-5AA UP30RLD-15AA

18 MM 30 MM

5 MM 15 MM

N.O N.O

20 HZ 20 HZ

D.C. 2 WIRE TYPE – 10-30V DC

21.

22.

HYP-12R-4TA HYP-18R-5TA

UP12RD-4TA UP18RM-5TA

12 MM 18 MM

4 MM 5 MM

N.O N.O

400 HZ 350 HZ

CAPACITIVE SENSORS – 10-30V DC

23.

24.

HCP-18RP-8AC HCP-30RP-15AC

CUP18RP-8FC CUP-30RP-15FC

18 MM 30 MM

5 MM 15 MM

N.C N.C

50 HZ 50 HZ

‘ HANYOUNG NUX ‘ WORLD LEADER IN CONTROL & MEASUREMENT

참조

관련 문서

This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in

Hauden, ^Miniaturized milk and surface acous ­ tic wave quartz oscillators used as sensors," IEEE Transactions on Ultrasonics, Ferroelectrics, and

The signal characteristics of FBG sensors under thermal loading should be investigated to enhance the reliability of these sensors, because they are exposed to

Textile strain sensors with piezore- sistivity are typically made using conductive yarn knit structures or carbon-based fillers or conducting polymer filler com- posite

Carbon Dioxide Sensors Principle of a pCO2 electrode electrodes for measurement of partial pressure of CO2 in blood or other liquid based on measuring the pH CO2+H2O ßà H2CO3ßàH+

In this paper, we implemented a glove which can measure finger movements and upper limb movements by using flex sensors whose resistance value changes according

proposed a target localization method utilizing the positions of target-detected sensors in distributed sensor network which consists of detection-only sensors.. In

[1] Overall, the linearity of capacitive and optical strain sensors is greater than that of resistive-type strain sensors (Table 1 and 2). The nonlinear response of