• 검색 결과가 없습니다.

Date: 24 feb 2014

N/A
N/A
Protected

Academic year: 2022

Share "Date: 24 feb 2014"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

1 2 3 4 5 6

1 2 3 4 5 6

A

B

C

D

A

B

C

D

Date: 24 feb 2014

KiCad E.D.A. eeschema (2014-08-05 BZR 5054)-product

Rev:

Size: A4

Id: 1/1

Title: Power meter

File: AD8307-PWR-meter.sch Sheet: /

PA3CSG

VCC

V-4V+8 1

2 - 3 +

U4A

LM358N

VCC

VCC R20

1k5

R21 1k5

R11150

R13 120

R17150 C6 10nF in1 com2 Off3 out4int5en6vcc7in8

U3 AD8307 C2

10nF

L2 100uH

C4 100nF VCC

R194.7

C9 10nF

R7150

R12 120

R14150 C7 10nF C1

10nF

L1 100uH

C3 100nF VCC

R184.7

C8 10nF

D1

1N4001 R9

1 VI VO

GND

U1 7805

C5 100nF

C12 10uF

VCC

V-4V+8 5 +

6 -

7

U4B

LM358N

C10 10nF

C11 10nF

C13

100nF

VCC

VCC R22

1k

R23 1k

C16

100nF

C17

100nF R24

1k

R25 1k

C18

100nF

C19

100nF

Forward Reflected

14 dB pad

R268

R4 150

R668

16 dB pad

R168

R3 150

R568

FWD REF

16 dB pad

R8150 R15150

R10150 R16150

14 dB pad

REF

FWD

in1 com2 Off3 out4int5en6vcc7in8

U2 AD8307

16x2

LEDK1 LEDA2 VSS3 VDD4 Vo5 RS6 R/W7 E8 DB09 DB110 DB211 DB312 DB413 DB514 DB615 DB716

DS1 HY1602E

HY1602E

R261M

C15 22pF

C14 22pF

X1 16MHz

C20 0.01uF (PCINT14/RESET)PC6

1

(PCINT16/RXD)PD0 2

(PCINT17/TXD)PD1 3

(PCINT18/INT0)PD2 4

(PCINT19/OC2B/INT1)PD3 5

(PCINT20/XCK/T0)PD4 6

VCC 7

GND 8

(PCINT6/XTAL1/TOSC1)PB6 9

(PCINT7/XTAL2/TOSC2)PB7 10

AVCC 20

(PCINT21/OC0B/T1)PD5 11

AREF 21

(PCINT22/OC0A/AIN0)PD6

12 GND 22

(PCINT23/AIN1)PD7 13

(PCINT8/ADC0)PC0 23

(PCINT0/CLKO/ICP1)PB0 14

(PCINT9/ADC1)PC1 24

(PCINT1/OC1A)PB1 15

(PCINT10/ADC2)PC2 25

(PCINT2/OC1B/SS)PB2 16

(PCINT11/ADC3)PC3 26

(PCINT3/OC2A/MOSI)PB3 17

(PCINT12/SDA/ADC4)PC4 27

(PCINT4/MISO)PB4 18

(PCINT14/SCL/ADC5)PC5 28

(PCINT5/SCK)PB5 19

IC1 ATMEGA328-P

VCC C21

100nF R33 1 ohm R32

R29 560

560 R31

10k R28

10k

R30 VCC 10k

Reset push butt.

FS Pwr push butt.

Mode SW push butt.

SWR Alarm led PWM Blower

VCC

VCC

GND

1 2 3 4

P4

CONN_4

1 2 3 4

P5

CONN_4

1 2 3 4

P6

CONN_4

1 2 3 4

P7

CONN_4

VS VDD VO RS RW E D0 D1 D2 D3 D4 D5 D6 D7 A

K

R27

47 VCC

VCC 1

2 3 RV110k

VCC 1

2

P1

BNC

1

2

P2

BNC

LCD 20 x 4

R3410k R35560 R368k2

1 2 3 4

P11 CONN_4 1 2 3 4

P10 CONN_4 1 2 3 4

P9 CONN_4

VCC

+5V

R3710k R3810k

0-100V input

C23 10nF

Current sens. 1 Current sens. 2

C26 10nF

C25 10nF

LM35 temp sens.

LCD connection

1 2 3 4

P8 CONN_4

1 : 20 1 : 2

R39

560 R40

560

General Alarm

R42 560

R41

Volt-AL

560

Volt-AL

CUR1-AL

CUR1-AL

CUR2-AL

CUR2-AL

TEMP-AL

TEMP-AL OSC2

OSC1

OSC2 OSC1

Volt Alarm Cur1 Alarm Cur2 Alarm Temp. Alarm Warn.

GEN-AL

SWR-AL

SWR-AL

RESET

RESET

D3 1N4148

D4 1N4148

D5 1N4148

D6 1N4148

D7 1N4148

GEN-AL

SWR-AL Volt-AL CUR1-AL CUR2-AL TEMP-AL

C24 10nF

C22 10nF

1 2 3 4

P3

CONN_4

R45 10k R46

10k

R44 10k

R43 10k

1 2 3 4

P12 CONN_4

VCC

E 1

B 2 C 3

REF1

LT1009 ref.

PWR_FLAG

R47 3k9 VCC

R48 560

E 1 B 2

C 3

REF2 BD139

C27 100uF 16V

R49 1k

From P11 #3

D2 1N4001

B

12V

Blower driver

NOT on PCB

참조

관련 문서

Solicitation Number: EHSP292103 Original Publish Date: 2015/04/27 Close Date & Time:

가압순산소 연소 기술은 기존의 순산소 연소 조 건에서 약 10 bar이상으로 가압하여 발전 운전하는 기술로써 기존 공정 대비 발전단 효율 향 상, FGC를 통한 배기가스의 NOx, SOx 저감

한국의 노동시장 지표를 OECD 고용선진국과 비교·분석하여 한국 노동시장의 현 주 소에 대한 이해를 돕고, 취약점 극복을 위한 정책 및 향후 노동정책의 방향을 제시하

: temporal pulse spread (psec) per unit spectral width (nm) per

- IMI International Management Institute Switzerland in Luzern에서 MBA과정수료 기회 제공 - 미국 시카고 North Park University MBA과정 입학 기회 제공.. 코드: GBD

특히 간 절제술과 간이식을 맡고 있는 외과 왕희정 교수팀은 국내 최초로 혈액형이 다른 간이식을 성공한 데 이어 간이식 수술을 통해 혈우병과 간암을 동시 치

Measurement device: Continuity test; test current up to 0,1A (option 3A), resistance from 10mOhm Insulation measurement; test voltage up to 750V, resistance up to

Fitted with an integrated sideshift and tilting car- riage as standard, the uniquely designed triplex fixed mast has no central lift cylinder which, together with the