Investigation on the Commercialization Issues of Resistive Type

Superconducting Fault Current limiters for Electric Networks

T. G. Park , S. H. Lee, B. W. Lee

Hanyang University, Ansan, Korea

Among the various types of fault current limiters, resistive superconducting fault current limiters are the most preferable choice for high voltage and high current electric power systems due to the excellent current limiting characteristics of superconductors. However, the real field application of resistive superconducting fault current limiter have been delayed by some technical issues. In order to promote the development and application of the superconducting fault current limiters, it is necessary to understand the electric power utilities’ requirements and suitable test method and some specifications should be suggested. This paper focuses on the matters of commercialization issues that were essential requirements for commercialization of superconducting fault current limiters. The performance and characteristics of resistive superconducting fault current limiters are reviewed and other standards including circuit breakers, transformers, reactors, power fuse, and fused circuit breakers were compared to setup novel test requirements of superconducting fault current limiters. Furthermore, the practical issues for resistive superconducting fault current limiters were discussed and the solutions for these matters were suggested.

참조

관련 문서

 Two or more circuit elements are said to be in series if the identical current flows through each of the elements.. • The two resistors are in series, since the

Symbol Parameter Test conditions Min. Test circuit for resistive load switching times and Figure 22.. Source drain diode.. Symbol Parameter Test conditions Min. Test

If customers use power supplies and controllers themselves, please follow the current allowed for wire cross-section to install over current protectors (such as fuse), on

1 John Owen, Justification by Faith Alone, in The Works of John Owen, ed. John Bolt, trans. Scott Clark, "Do This and Live: Christ's Active Obedience as the

In this paper, the variable capacitors and the superconducting relay antenna were applied to the superconducting WPT system to increase efficiency and the transmission distance

Current study explores the effects of entrepreneurial orientation both on financial and innovative performance with 1,497 Korean small and medium-sized

A Study on the Wireless Power Transmission of magnetic resonance using Superconducting

And we introduce you to the terminal caracteristics, and linear and lumped constant characteristics about electric circuit elements, which are voltage source,