• 검색 결과가 없습니다.

Microbial Detection and Identification Using Biosensors S10-5

N/A
N/A
Protected

Academic year: 2022

Share "Microbial Detection and Identification Using Biosensors S10-5"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

www.msk.or.kr 135

The 48th MSK Annual Meeting and 2008 International Symposium on Microbiology

S10-5

Microbial Detection and Identification Using Biosensors

Sol Kim

Bio Food Team, Korea Food and Drug Administration, Seoul 122-704

Abstract

Various biosensors were evaluated for identifying and detecting foodborne pathogens in a rapid and effective manner. First, five strains of Escherichia coli and six strains of Salmonella were identified using Fourier transform infrared spectroscopy and a statistical program. For doing this, lipopolysaccharides (LPSs) and outer membrane proteins (OMPs) were extracted from a cell wall of each bacterial strain.

As a result, each strain was identifed at the level of 97% for E. coli and 100% for Salmonella. Second, E. coli O157:H7, S. Enteritidis, and Listeria monocytogenes were identified by multiplex PCR products from four specific genes of each bacteria using a capillary electrophoresis (CE). Also, ground beef for E. coli O157:H7, lettuce for S. Enteritidis, and hot dog for L. monocytogenes were used to determine the possibility of detecting pathogens in foods. Foods inoculated with respective pathogen were cultivated for six hours and multiplex PCR products were obtained and assessed. The minimum detection levels of tested bacteria were <10 cells/g, <10 cells/g, and 104 cells/g for E. coli O157:H7, S. Enteritidis, and L. monocytogenes, respectively. Third, it was possible to detect S. Typhimurium in a pure culture and lettuce by a bioluminescence-based detection assay using both recombinant bacteriophage P22::luxI and a bioluminescent bioreporter. In addition, bacteriophage T4 was quantitatively monitored using E. coli including luxCDABE genes.

참조

관련 문서

It is difficult to diagnose the status of the governor valves using only Fourier transform analysis, so three features from the Fourier transform and one feature from

Abstract To determine whether metabolite fingerprinting for whole cell extracts based on Fourier transform infrared spectroscopy (FT-IR) can be used to discriminate and

In this study, we compared bacterial endotoxin using Escherichia coli O157:H7, Klebsiella oxytoca , Salmonella Typhi, Shigella sonnei and Morganella morganii..

Structural changes and interfacial reactions between the glass substrate and the glass frit after sintering (at 400 o C for 1 h) were measured by Fourier

By using STFT(short time fourier transform), noise sources of a rotary compressor were identified and vibrating modes that increase the noise are verified.. Also,

Polymer materials of EQ cables for Yonggwang Unit 1&amp;2 were analyzed using FT-IR (Fourier Transform Infrared Spectroscopy), TGA (Thermo-Gravimetric Analysis), and

In this study, Fourier transform infrared (FT-IR) spectroscopy was employed as a fast non-destructive method in conjugation with multivariate regression analysis to build a

채취된 검체에 대해 총 12종의 설사원인 세균성 병원체인 Vibrio cholerae, Vibrio parahaemolyticus, enterohemorrhagic Escherichia coli (EHEC), ETEC, Salmonella