• 검색 결과가 없습니다.

Annals of Surgical Treatment and Research

N/A
N/A
Protected

Academic year: 2021

Share "Annals of Surgical Treatment and Research"

Copied!
5
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Supplementary Table 1. Cell viability (%) of MDA-MB-231 and MDA-MB-468 after treatment with docetaxel and ABT-737 by MTT assay (Fig. 1B, C)

Concentration (μM) Docetaxel ABT-737

MDA-MB-231 MDA-MB-468 MDA-MB-231 MDA-MB-468

0 100.0 ± 0.0 100.0 ± 0.0 100.0 ± 0.0 100.0 ± 0.0

0.001 100.3 ± 1.1 44.5 ± 1.8 104.5 ± 4.9 92.5 ± 12.7

0.01 78.5 ± 2.0 28.4 ± 5.4 105.4 ± 6.4 99.0 ± 11.7

0.1 58.8 ± 1.7 19.6 ± 1.8 103.3 ± 4.2 69.0 ± 1.7

1 58.1 ± 2.2 18.6 ± 3.0 84.2 ± 7.1 85.1 ± 9.7

2.5 61.5 ± 1.3 23.0 ± 5.7 54.1 ± 8.8 79.2 ± 13.6

5 64.7 ± 1.9 32.3 ± 3.0 29.9 ± 6.3 64.5 ± 7.8

10 68.4 ± 1.1 33.1 ± 4.1 10.1 ± 2.8 41.9 ± 7.0

20 71.3 ± 0.6 25.5 ± 7.6 0.5 ± 0.9 12.1 ± 3.7

40 72.9 ± 1.3 19.8 ± 5.8 1.1 ± 1.6 3.6 ± 1.9

Values are presented as mean ± standard deviation.

MTT, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide.

(2)

Supplementary Table 2. MTT absorbance at the wavelength of 570 nm after treatment with docetaxel, ABT-737, and combination using MDA-MB-231 (Fig. 2B)

Vehicle Docetaxel ABT-737 Combination

Absorbance (570 nm) 0.44 ± 0.03 0.43 ± 0.03 0.48 ± 0.07 0.28 ± 0.01

Values are presented as mean ± standard deviation.

MTT, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide.

(3)

Supplementary Table 3. Cell cycle analysis (% of each phase) after treatment with docetaxel, ABT-737, and combination using MDA-MB-231 cells (Fig. 3B, C)

Phase Vehicle Docetaxel ABT-737 Combination

SubG1 12.7 ± 2.7 26.0 ± 3.7 33.4 ± 5.2 59.6 ± 5.0

G1 48.0 ± 9.8 11.8 ± 0.9 4.0 ± 0.2 7.9 ± 0.8

S 18.3 ± 10.2 27.9 ± 2.9 38.8 ± 2.7 10.9 ± 1.1

G2/M 16.8 ± 0.7 16.1 ± 2.6 10.5 ± 2.7 9.1 ± 0.9

Values are presented as mean ± standard deviation.

(4)

Supplementary Table 4. Cell viability (%) after treatment with docetaxel, ABT-737, and combination using MDA-MB-231 with or without pretreatment of z-VAD-fmk by MTT assay (Fig. 4A)

Docetaxel ABT-737 Combination

z-VAD-fmk (-) 97.1 ± 6.4 107.9 ± 20.4 62.7 ± 1.7

z-VAD-fmk (+) 109.2 ± 11.6 119.2 ± 27.6 108.3 ± 18.9

Values are presented as mean ± standard deviation.

z-VAD-fmk, benzyloxycarbonyl-Val-Ala-Asp(OMe)-fluoromethylketone; MTT, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide.

(5)

Supplementary Table 5. Cell cycle analysis after treatment with docetaxel, ABT-737, and combination using MDA-MB-231 with or without pretreatment of z-VAD-fmk (Fig. 4C)

Phase Vehicle Docetaxel Docetaxel

+ z-VAD-fmk ABT-737 ABT-737

+ z-VAD-fmk Combination Combination + z-VAD-fmk

SubG1 14.8 24.2 19.5 25.4 1.4 40.8 9.6

G1 36.6 26.6 28.2 46.9 68.7 27.1 45.2

S 30.0 1.4 1.7 3.0 3.0 3.5 8.1

G2/M 17.1 9.4 14.5 9.1 16.5 10.0 18.3

Values are presented as mean ± standard deviation.

z-VAD-fmk, benzyloxycarbonyl-Val-Ala-Asp(OMe)-fluoromethylketone.

참조

관련 문서

Conclusion : The treatment using facet joint block with lumbar surgical operation seems to have short term clinical effects, however can't prevent

In the analysis of soluble solids, the treatment group with material grains and the combined groups of glutinous millet and barley appeared high, and

Concentration of soil residual endosulfan-sulfate with days after treatment of endosulfan in different soils

The average tensile strength value before heat treatment of PLA output was 9.67 N/㎟, and the average tensile strength value after heat treatment was 24.17 N/㎟, which

Approved clinical use of bone marrow stem cells for myocardial infarction treatment... Cardiac

verify that USF2 interacts with BRCA1 in HeLa cells, and investigate changing interaction between.. BRCA1 and USF2 after treatment of ionizing radiation (IR), we

Grunder U, Hürzeler MB, Schüpbach P, Strub JR: Treatment of ligature-induced peri-implantitis using guided tissue regeneration: A clinical and histologic study

The combination treatment of PBA and 6-gingerol induced the cleavage of caspase-3, caspase-4, PARP, GRP78, p-eIF2α, and CHOP in DU145 cells and Western blot analysis for