Vol. 3, No. 2 (2010) pp. 84 − 88

반사공명으로 인코딩된 광결정 스마트 먼지의 제조방법 및 광학적 특징

이보연1·황민우1·조 현1·김희철1·힌정민2

Preparation and Optical Characterization of Photonic Crystal Smart Dust Encoded with Reflection Resonance

Boyeon Lee1, Minwoo Hwang1, Hyun Cho1, Hee-Cheol Kim1 and Jungmin Han2†

Abstract

Photonic crystals containing rugate structures from a single crystalline silicon wafer was obtained by using a sinoidal alternating current during an electrochemical etch procedure. Photonic crystals were isolated from the silicon substrate by applying an electropolishing current and were then made into particles by using an ultrasonic fracture in an ethanol solution to give a smart dust. Smart dusts exhibited their unique nanostructures and optical characteristics. They exhibited sharp photonic band gaps in the optical reflectivity spectrum. The size of smart dust obtained was in the range of 10-20 nm.

Key words : Photonic crystal, Rugate, Smart dusts

1. 서 론

스마트먼지 (smart dust)”원래미세전자공학으 로부터유도된제작기술을사용하여만들어진무선 도체장치를소형화한것을의미한다. 이런장치들은 센티미터크기의물품으로감지연산, 통신을

있다. 무선통신분야의선구자인 Kristofer Pister 1997

년에처음으로스마트먼지란개념을사용하였다.[1] 들어 Michael Sailor기능을갖는마이크로미터

크기의광결정을다공성실리콘으로부터얻고광결 정들이여러가지광학적, 화학적, 기계적특징들을 지고있으며이런특성들은감지신호처리, 통신

이용될있다고보고하였다.[2]스마트먼지가 존의실리콘제조기술을이용하여대량생산이가능하 다면제조에있어매우저렴할것이다. 이들의잠재적

활용가능분야는대형건물의객실에서온도 조절할있으며화학생물학적테러로부터

감지추적을하는데응용할있다.

스마트먼지는높은표면적과편리한표면화학, 신호변환능력에기인하여[1-5]화학[6]생물학적 센서,[7]의료진단,[8]광학필터,[9]마이크로화학반응

,[10]마이크로연료전지[11]등에응용이가능하다. 마트먼지는실리콘웨이퍼의전기화학적식각을통해 간단하고저렴하게만들있으며실리콘입자들이 구물모양의나노구조로이루어져서높은표면적을 지고있으며나노크기의기공과독특한광학적성질을 가지고있다. 기공의표면을산화시키거나알킬화반

응을시켜서친수성소수성을갖는다양한표면 질을갖게제조할있다. 이는기공의표면과화학물 질이상호작용을서로다른정도를인식하게 결과감지에있어다른신호를얻게된다. 스마 먼지의소재인다공성실리콘기공의크기는 노미터에서마이크론까지조절이가능하며, 기공의

직경과방향은전기화학적부식흘려준전류의 기와실리콘웨이퍼에불순물의형태로첨가한첨가제 , HF, 실리콘웨이퍼의종류에따라달라 .[12-15]

논문에서실리콘표면을유도체하여안정화시킨 스마트먼지의제조방법광학적특성에대해보고 하고자한다.

1조선대학교화학과(Department of Chemistry, Chosun University, Gwangju, 501-759, South Korea)

2한국화학연구원(Biorefinery Research Center, Korea Research Institute of Chemical Technology, Jang-dong, Daejon, 100)

Corresponding author: eglantier@nate.com (Received : June 14, 2010, Revised : June 21, 2010, Accepted : June 24, 2010)

(2)

2. 실 험

2.1. Rugate 광결정의 제조

순수한 p++-type 실리콘 단결정 웨이퍼 (boron dopped, <100>, 0.0008~0.0012 ) source meter (Keithley 2420)이용하여전류를흘려주어전기

학적식각을하게되면 rugate 광결정을합성할 . 부식용매로는 HF 용액 (48% 중량비, Fisher Scientific)에탄올 (Fisher Scientific)사용하였으며 HF : 에탄올 = 3 : 1부피비를갖도록준비하였다.

전기화학적부식은두개의전극을사용하여 Teflon cell 안에서수행하였다. Rugate 광결정을만들기위해

흘려준전류는 sine 파형의전류를흘려주어굴절률의

병화가수직방향을따라점차적으로 sine파의변화와

같이변하게하였다. Modulated sinusoidal function

간단히구현하기위해서가상의 sine 파형프로그램인

Matlab 7.0이용하여구현하였으며 sine파형의전류

컴퓨터로제어하여흘려주었다. (그림 1)

전류의세기는 62.5-125.6 mA·cm-2 0.74 Hz

인파형을 100초씩 20반복하여흘려주었다. 모든

공정은 Teflon etch cell에서수행하였다. 식각후에는 에탄올과아르곤가스를이용하여세척하고건조하였 .

2,2. 광학 인코딩된 Rugate 광결정의 제조

Rugate 구조를갖는실리콘광결정은식각조건

sine형태의직류전류를이용하여식각을하여

있다. Ruagte 광결정의경우는다음(1)

용하여합성할있다.

Y = A·sin (f*t) + Acenter (1)

A진폭, f진동수(Hz), t시간, Acenter파형의 중앙값이된다. 사인파의파형과식각조건을조절하여

rugate 실리콘광결정을제작할있는데 rugate 실리 광결정의장점은사인파를이용하여파형에대한

FFT(퓨리에변환)하면다공성실리콘에서반사되어

오는빛의상쇄와보강간섭으로인한반사피크를미리 예측할있다. 나아가반사피크들이상대적인

기를조절할있도록광학인코딩(optical encoding)

있다. 다중반사피크를얻을있는광학인코 딩은바코드기술과비교할있으며여러가지분석 물질들을단시간에감지할있는다중검출기술로서 생물분자를감지할이용될있다. 다중 rugate 리콘광결정의경우 Y = A·sin (f*t) + Acenter사인파 공식을이용하여다중멀티신호를가진실리콘광결 정을제작할있는데이는(2)이용하여얻을

있다.

Yi = Ai[1 + sin(fi*t-Bi)] + Ai,min (2)

복합형사인파의각각의변수는 Ai i번째 sine파의

진폭, fi i번째 sine파의진동수(Hz), Bi sine파의 변위, Ai,min i번째 sine진폭의최소값이며따라

Yi i개의 sine파의합성파(composite wave)된다.

2.3. Rugate 실리콘 광결정 구조를 갖는 스마트 먼 지의 제작

얻어진 rugate 실리콘광결정에고전류 450 mA

에탄올:HF 1:3용액을사용하여 1.5분간걸어주고

저전류 29 mA에탄올:HF 15:1용액을사용하여

1.5분간걸어주어 rugate 실리콘광결정을웨이퍼에서

분리해냈다.

그런분리된 rugate 실리콘광결정을 100 mL hexane

들어있는 250 mL 플라스키에넣은 Ultrasonic apparatus (Branson 5210, 50-60 Hz) 사용하여마이

크로미터또는나노미터의크기로분쇄하였다. 아래의 그림 2일반적인 rugate 실리콘광결정스마트먼지

대한제작과정을도식화한것이다.

그림 1. Matlab 프로그램을이용한 Sine 파형의도식.

Fig. 1. Diagram for sine wave produced by Matlab

program. 그림 2. 스마트먼지의제조공정.

Fig. 2. Preparation process for smart dust.

(3)

2.4. 측정기기

rugate 실리콘광결정스마트먼지샘플들의반사

스펙트럼을측정하기위한분광학기기는 Ocean Optics

USB 2000 사용하였으며반사스펙트럼을얻기

광원은텅스텐-할로젠램프를이용하였고수광

서로는 USB 2000 CCD detector이용하였다. 수광

센서는컴퓨터에연결되어광학특징을측정하였다. 기화학적식각을수행하는데이용된기기로는 Galvano- stat (Keithley 2420 Source meter)이용하였으며

각의샘플들의식각깊이를측정하기위해 cold field emission scanning electron microscope(FE-SEM, S-4700, Hitachi)의해서측정하였다.

3. 결과 및 고찰

Rugate 실리콘광결정은나노구조를가지고있으며

sine형태의직류전류를이용하여전기화학적식각을

통하여얻을있다. 그림 3실험으로얻어진 rugate

실리콘광결정의표면() 측면(아래) FE-SEM 진을나타낸것이다. 그림에서보는바와같이 rugate

실리콘광결정의표면은실리콘이그물모양의나노구

조를형성하고있음을나타내며기공의크기가 10-

20 nm 크기를가지고있음을나타내고일정한모양을

보여주었다. 또한측면사진을보면기공이수직으로 형성되어있음을나타내고있다.

Rugate 실리콘광결정은 electropolishing 조건을

용하여실리콘웨이퍼로부터필름형태로분리하여 있다. 필름의두께는수십마이크론이었다. 러나이런필름상태의 rugate 실리콘광결정은조그만

힘을가하여도부서지기쉬운특징을가지고있다. 라서필름을유기용매가담긴플라스크에넣은 초음파분쇄기를이용하여분쇄를하였다.

그림 4초음파분쇄로얻어진스마트먼지의사진 이다. 초록색으로보이는스마트먼지들은표면이

그림 3. Rugate 실리콘광결정의표면() 측면(아래) 주사현미경사진.

Fig. 3. Surface (top) and cross-sectional FE-SEM images of rugate silicon photonic crystals.

그림 4.스마트먼지의사진.

Fig. 4. Photograph of smart dust.

그림 5.스마트먼지의주사현미경사진.

Fig. 5. FE-SEM images of smart dusts.

(4)

입사각과수직으로되어있어반사공명이나타난것으 여겨진다.

그림 4초음파분쇄를통하여얻어진스마트먼지

FE-SEM 사진이다. 보는바와같이초음파분쇄를

통하여얻어진스마트먼지의크기는초음파분쇄시간 관계되며분쇄시간이길어질수록스마트먼지의 기는작아졌다. 실험에서 90동안의초음파분쇄

얻어진스마트먼지의크기는대략 20-40 마이크로

미터크기로균일하게얻어짐을확인할있었다.

그림 6초음파분쇄로얻어진스마트먼지의측면

FE-SEM 이미지이다. 이는초음파분쇄후에도나노구

조를원래상태그대로지니고있는것을확인시켜 었다.

그림 7얻어진스마트먼지의반사공명스펙트럼

이다. 스마트먼지는 500 nm에서반사공명을 타낸다는것을확인하였다.

4. 결 론

Rugate 실리콘광결정으로부터초음파분쇄를통해

스마트먼지를제작하였으며초음파분쇄시간에따라 스마트먼지의크기는조절할있었다. 스마트먼지

초음파분쇄나노구조를그대로유지하고있었

으며광학적특성또한그대로유지하고있었다. 90

초음파분쇄로얻어진스마트먼지의크기는 20-40

마이크로미터크기로균일하였으며기공의크기또한 수십나노미터의크기로균일하게얻었다.

참고문헌

[1] J. R. Link and M. J. Sailor, “Smart dust: Self-assem- bling, self-orienting photonic crystals of porous Si”, Proc. Natl. Acad. Sci., Vol. 100, p. 10607, 2003.

[2] A. Janshoff, K.-P. S. Dancil, C. Steinem, D. P.

Greiner, V. S.-Y. Lin, C. Gurtner, K. Motesharei, M.

J. Sailor, and M. R. Ghadiri, “Macroporous p-type silicon Fabry-Perot layers. Fabrication, character- ization, and applications in biosensing”, J. Am.

Chem. Soc., Vol. 120, p. 12108, 1998.

[3] K.-P. S. Dancil, D. P. Greiner, and M. J. Sailor, “A porous silicon optical biosensor: detection of revers- ible binding of IgG to a protein A-modified sur- face”, J. Am. Chem. Soc., Vol. 121, p. 7925, 1999.

[4] D. van Noort, S. Welin-Klinstrom, H. Arwin, S.

Zangooie, I. Lundstrom, and C.-F. "Mandnius, Monitoring specific interaction of low molecular weight biomolecules on oxidized porous silicon using ellipsometry”, Biosens. Bioelectro., Vol. 13, p. 439, 1998.

[5] S. Chan, S. R. Horner, B. L. Miller, and P. M.

Fauchet, “Identification of gram negative bacteria using nanoscale silicon microcavities”, J. Am.

Chem. Soc., Vol. 123, p. 11797, 2001.

[6] H. Sohn, S. Letant, M. J. Sailor, and W. C. Trogler,

“Detection of fluorophosphonate chemical warfare agents by catalytic hydrolysis with a porous silicon interferometer”, J. Am. Chem. Soc., Vol. 122, p.

5399, 2000.

[7] V. S.-Y. Lin, K. Motesharei, K.-P. S. Dancil, M. J.

Sailor, and M. R. Ghadiri, “A porous silicon-based optical interferometric biosensor”, Science, Vol.

278, p. 840, 1997.

[8] M. Simion, I. Kleps, T. Neghina, A. Angelescu, M.

그림 6.스마트먼지의표면주사현미경사진.

Fig. 6. FE-SEM images of surface of smart dusts.

그림 7.스마트먼지의반사공명스펙트럼.

Fig. 7. Reflectivity spectrum of smart dust.

(5)

Miu, A. Bragaru, M. Danila, E. Condac, M. Cos- tache, and L.Savu, “Nanoporous silicon matrix used as biomaterial”, J. Alloy. Compd., Vol. 434, p. 830, 2007.

[9] S. Ilyas, T. Bocking, K. Kilian, P. J. Reece, J. Good- ing, K. Gaus, and M. Gal, “Porous silicon based narrow line-width rugate filters”, Opt. Mater., Vol.

29, p. 619, 2007.

[10] M. A. Khan, M. S. Haque, H. A. Naseem, W. D.

Brown, and A. P. Malshe, “Microwave plasma chemical vapor deposition of diamond films with low residual stress on large area porous silicon sub- strates”, Thin Solid Films, Vol. 332, p. 93, 1998.

[11] S. E. L´etant, S. Content, T. T. Tan, F. Zenhausern, and M. J. Sailor, “Integration of porous silicon chips in an electronic artificial nose”, Sensor Actuat. B- Chem., Vol. 69, p. 193 2000.

[12] C. Levy-Clement, A. Lagoubi, and M. J. Tomk- iewucz, “Theoretical model for early stages of porous silicon formationfrom n-and p-type silicon substrates”, Electrochem. Soc., Vol. 278, p. 840,

1997.

[13] J. M. Laucerhaas and M. J. Sailor, “Chemical Mod- ification of the Photoluminescence Quenching of Porous Silicon”, Science, Vol. 261, p. 1567, 1993.

[14] M. S. Yoon, K. H. Ahn, R. W. Cheung, H. Sohn, J. R. Link, F. Cunin, and M. J. Sailor “Covalent crosslinking of 1-D photonic crystals of microporous Si by hydrosilylation and ring-opening metathesis polymerization”, Chem. Commun., Vol. 680, p.

8246, 2003.

[15] J. Kim, S. Jang, Y. Koh, C. Park, H.-G. Woo, S.

Kim, and H. Sohn, “Fabrication of Multi-Optical Filters Based on Encoded Rugate Porous Silicon”, J. Nanosci. Nanotechnol., Vol. 8, p. 4951, 2008.

[16] H. Gerischer, P. Allogue, V. Kieling, and B. Bun- senges, “The mechanism of the anodic oxidation of silicon in acidic fluoride solutions revisited”, Chem.

Phys., vol. 97, p. 753, 1993.

[17] K. S. Dancil, D. P. Greiner, and M. J. Sailor, “Devel- opment of a porous silicon based biosensor”, J. Am.

Chem. Soc., Vol. 121, p. 7925, 1999.

참조

관련 문서

Photoluminescence properties and surface morphologies of porous silicon were investigated by controlling of etching times and applied current densities..

Then, body idioms by parts were classified by emotional types and &lt;Emotional Type Classification in Korean and Japanese&gt; was made.. Frequently used

Lumbar discogenic radiculopathy (LDR) is one of the most common spinal disorders which can lead to high medical expenses for the patient, occupational impairment,

Changing the internal atomic positions by applying stresses to the metal distorts the energy bands slightly, resulting in small changes in the amount of conduction that results

The preparation of osseodensification technique should start with a smaller diameter than conventional technique because of the recovery of elastic strain. It

Type 2 The number of lines degenerate to a point but there is no degeneration of two dimensional phase regions.. Non-regular two-dimensional sections.. Nodal plexi can

Type 2 The number of lines degenerate to a point but there is no degeneration of two dimensional phase regions.. Non-regular two-dimensional sections. Nodal plexi can be

Photonic crystals containing rugate structure result in a mirror with high reflectivity in a specific narrow spectral region and are prepared by applying