• 검색 결과가 없습니다.

★..한국실내환경학회 KOSIE

N/A
N/A
Protected

Academic year: 2021

Share "★..한국실내환경학회 KOSIE"

Copied!
9
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

http://dx.doi.org/10.15250/joie.2016.15.3.213 ISSN 2288-923X (Online)

온도와 습도에 따른 VOCs 악취센서의 반응특성 평가

공부주1·한진석2·김형천1·봉춘근3·박정민1*·이상보1·홍지형1

1

국립환경과학원,

2

안양대학교 환경에너지공학과,

3

(주)그린솔루스

Assessment of performance of VOCs odor sensors at different levels of temperature and humidity

Bu Ju Gong1·Jin Seok Han2·Hyeong Cheon Kim1·Chun Geun Bong3 Jeong Min Park1*·Sang Bo Lee1·Ji Hyung Hong1

1

National Institute of Environmental Research.

2

Department of Environmental and Energy Engineering, Anyang University

3

Green Solus Corporation

(Received 23 May, 2016; Revised 3 July, 2016; Accepted 27 July, 2016) Abstract

The study analyzed performance assessment factors of VOCs odor sensors from 3 different manufacturers, such as minimum detection limit, humidity stability and temperature stability. Through the minimum detection limit assessment, it was found that a VOCs sensor was able to detect TVOCs at the concentration of 5 ppb. The standard deviation ratio was over 10%, and it increased as humidity rose. The range of temperatures in which the VOCs odor sensor using photoionization could operate was between 25

o

C and 40

o

C, and the sensor output values were unstable at low temperatures. In terms of the temperature stability of the metal oxide semiconductor sensor for measuring complex odors, the sensor output values dropped considerably to 0~10

o

C, and were similar to the concentrations of odorous gases generated at 25

o

C. The results of the test of VOCs odor sensor outputs after temperature and humidity pre-treatment revealed that the respective stable output values at 50% humidity and 25

o

C were similar to the concentrations of manufactured odors. In terms of temperature and humidity stability of the VOCs odor sensors, all target VOCs substances had stable output values at 25

o

C to 40

o

C and at 50% to 65%

relative humidities, and unstable values at low temperatures and high humidities. Therefore, the implementation of pre-treatment systems including temperature and humidity correction (25~40

o

C, 50~65% RH) is required for the stable use of VOCs odor sensors.

Keywords : Minimum detection limit of odor sensor, Temperature and humidity stability of VOCs odor sensor, TVOC concentration

1. 서 론

국내에서 많이 발생하는 악취 문제는 배출원이 다양 하고 그 피해범위가 광범위하며, 평균농도가 아닌 고농 도의 순간농도에 의해 발생하는 감각적인 특성이 있으 며, 악취를 유발하는 원인물질이 매우 다양하고 지역마

다 국지적인 특성이 있기 때문에 그 해결이 어려운 실 정이다.

국민들의 생활수준 향상과 쾌적한 환경에 대한 요구 가 증대됨에 따라서 악취를 포함한 생활환경에 대한 관심과 민원이 증가하고 있으며 환경부에서 우리나라 전국을 대상으로 악취 민원 현황을 분석한 결과에 의 하면 쾌적한 생활환경에 대한 요구 증대로 악취 민원 은 ’05년 4,302건, ’10년 7,247건, ’14년 14,816건으로

*Corresponding author

Tel : +82-32-560-7336 E-mail : [email protected]

(2)

증가하고 있으며, 특히 ’14년도 악취 민원 건수의 경우 악취방지법이 시작된 ’05년도 대비 약 3.4배 증가한 것 으로 제시하고 있다(ME, 2015).

이에 따라 환경부에서는 악취 문제의 개선을 위하여 악취방지법으로 복합악취 및 황화합물, 알데하이드류, 암모니아, 아민류, 그리고 휘발성유기화합물질(VOCs) 등 22종의 지정악취물질을 규제하고 있다. 이러한 악 취물질의 주요 발생원은 생선가공업체, 도축장, 피혁공 장, 쓰레기 매립장, 도장시설, 금속 세정시설, 석유화학 시설, 하수 및 폐수처리장에서 발생되고 있다.

현재 우리나라의 악취 측정방법은 악취공정시험기준 에서 제시하고 있는 기기분석법과 공기희석관능법이 있는데, 기기분석법으로는 흡광광도법, 분광분석방법 과 GC, LC, GC/MS 방법 등이 있으며, 공기희석관능 법은 다수의 악취판정인이 단계적인 희석배수와 판정 인별 냄새감지 유무를 통해 최종적인 복합악취 희석배 수의 결과를 도출하는 방법이다(ME, 2014). 기기분석 법의 경우 고가이며 고도의 분석기술을 필요로 하며, 공기희석관능법의 경우 재현성 및 정도관리의 문제점 을 안고 있다. 가장 큰 문제는 악취자동측정시스템이 없는 지역의 경우 두 방법 모두 오프라인 방법으로 시 료를 채취하여 분석하는 방법이기 때문에 악취 민원이 발생한 시점의 시료는 채취하기가 쉽지 않고 또한, 분 석에 많은 시간이 소요되므로, 짧은 시간 내에 광범위 하게 악취 민원의 문제점을 실시간으로 대처하기가 어 렵다.

최근 악취 측정기의 기술개발 동향을 살펴보면 악취 측정기는 악취센서 등 분석기기를 이용하는 방식으로 UV 방법 등을 이용하여 H

2

S, NH

3

, VOCs 등 악취 개 별물질 측정, 반도체를 이용한 복합악취 측정 등으로 개발되고 있다.

악취센서의 작동원리는 악취물질이 센서에 흡착되어 산화되는 과정 또는 흡·탈착과정에서 발생되는 전기 전도도, 전기용량, 전류, 전압, 온도 등의 차이를 이용 하는 것이다. 악취센서는 이들 signal 값의 변화를 이용 하여 악취의 강도와 물질의 농도를 측정하는 것으로 센서의 signal pattern 변화로부터 악취지문을 분류하고, 그 세기를 측정함으로서 악취의 종류와 농도를 측정할 수 있다.

악취센서는 금속산화물반도체, 전도성 고분자, schottky 다이오드, MOSFET, thermistor, ECM 등의 다양한 소자들을 사용하며 대부분의 악취센서들은 ppm 수준의 악취물질 분석에 적합하다(Gong et al,.

2015; NIER, 2015).

금속산화물반도체 센서(metal oxide semiconductor)

는 금속산화물에 가스가 접촉되면 전기전도도 값이 변 화하는 원리를 이용하는 것으로 전기전도도 형성 방법 에 따라 소결체형, 후막형, 박막형, 커패시터형 및 MOSFET 형으로 구분되며, 가스흡착에 따른 부하저항 양단의 전압을 측정하는 것으로 검출된다. 커패시터형 및 MOSFET형 센서는 비전기저항식 가스센서의 구조 로 감지게이트 물질을 사용한다(Heo et al., 2006).

전기화학식 센서(electro chemical)는 검지 대상가스 를 전기화학적으로 산화 또는 환원하여 그 때 외부회 로에 흐르는 전류를 측정하는 장치이며 선택적 환원반 응으로 황화수소, 암모니아, 메틸머캅탄, 일산화탄소, 이산화황 등 개별가스에 선택 반응이 높다(NIER, 2014). 고체 전해질식 가스센서는 높은 온도에서 이온 의 이동에 따른 전도성으로 보이는 물질이 이용되며 광이온화 센서(photo ionization detector)는 선택적 광 반응 센서로 자외선 조사에 의한 가스분자의 공진을 흡수 또는 산란 량으로 취하는 원리를 이용하고 TVOCs(BTEXs) 모니터링에 사용하며, 일부 VOC 개 별물질 농도에 선택적으로 반응하므로 ppm 단위의 정 량적 분석이 가능하다(NIER, 2014).

그러나 고온/고습/고농도의 악취가스가 배출되는 악 취배출시설 및 악취방지시설에 가스센서를 설치하여 실시간 농도를 측정할 경우에는 가스센서가 시간이 지 남에 따라 점차 감도가 감소하거나 심할 경우에는 가 스센서가 고장나는 등의 문제를 일으킬 수 있다(Kim et al., 2012)

복합악취 측정을 위한 반도체식 가스센서의 특성은 악취성분에 대한 감도 및 반응속도는 탁월하나 선택성 은 부족하여 후각에 의한 관능평가를 대신할 목적으로 활용되고 있다.

암모니아, 황화수소 및 TVOC 측정을 위한 전기화 학식 및 광이온화식 가스센서의 특성은 악취물질의 개 별 성분에 대한 선택성 및 감도가 우수하고 모든 악취 성분의 측정을 대변할 수 없어, 개별 성분이 배출되는 지점에서 개별 악취농도 측정을 위한 목적으로 활용되 고 있다.

현재 우리나라에서 사용되고 있는 악취센서의 종류 는 3가지가 있으며, 암모니아, 황화수소 등의 단일물질 군에 선택적 반응을 나타내는 전기화학식 센서, TVOC 에 반응하는 광이온화 센서, 사람의 후각과 유사하게 반응하는 복합악취 측정용으로 금속산화물반도체 센서 가 가장 많이 사용되고 있다(Kim et al., 2010a, Kim et al., 2010b; NIER, 2014).

본 연구에서는 VOCs 악취센서의 최소감지 농도, 온

도 및 습도 안정성 실험을 통하여 악취를 실시간으로

(3)

측정할 수 있는 VOCs 악취센서의 현장에서의 적용을 위한 신뢰성과 측정 조건을 파악하고자 하였다.

2. 연구내용 및 방법

본 연구에서는 악취물질 중 TVOC에 대하여 광이온 화식 가스센서 방식을 이용하여 실험하였으며, 성능평 가에 사용된 악취센서 측정기 현황은 Table 1과 같다.

또한, 악취가스가 센서 측정기에 잘 공급되도록 가스유 도 캡을 자체 제작하여 외부가스의 방해 없이 악취센 서에 악취가스가 일정한 유량으로 주입될 수 있도록 하였다.

2.1 VOCs 악취센서의 온도와 습도에 따른 감지특성 VOCs 악취센서의 감지특성 분석을 위해서 우리나라 의 기온 및 습도 특성과 VOCs 악취센서별 최소감지농 도를 고려하여 실험조건을 선정하여 악취센서별 최소 감지농도 평가와 감지농도 및 신호체계의 온도 및 습 도 영향에 대한 성능평가를 수행하였으며, 성능지표 항 목별 평가요소와 방법은 Table 2와 같다.

2.2 VOCs 악취센서의 온도와 습도에 따른 안정성 VOCs 악취센서의 온·습도 안정성 실험을 위해서 악취센서 제조업체의 현황조사를 통해 선정된 VOCs 악취센서 및 자체 제작된 센서모듈을 온·습도 조건을 맞추고 주사기로 악취가스를 주입하여 농도 셋팅 후 5

번 반복실험을 수행하였다. 또한, 악취가스 주입유량에 따른 센서 출력값이 달라질 수 있으므로, 각 제조사별 센서 사양을 참고하여 적정 악취가스량을 주입하였다.

VOCs 악취센서의 온도 및 습도 안정성 실험은 우리 나라의 기온 및 습도 특성과 VOCs 악취센서별 최소감 지농도 및 현행 지정악취물질 배출허용기준을 고려하 여 실험조건을 선정하여 Table 3 및 Table 4와 같이 무 취백에 임핀저, 실리카겔, atomizer를 이용하여 습도를 조절하고 환경챔버를 이용하여 온도를 조절하였다.

VOCs 악취센서의 성능평가 실험은 Fig. 1에서와 같 이 유량조절, 습도조절, 온도조절 부분 등으로 구성되 어 있다. 온·습도 조건이 맞춰진 무취백을 챔버에 넣 고 온·습도센서를 이용하여 무취백의 온·습도를 최 종 확인한 후 악취센서 주입구에 캡을 장착하여 악취 가스를 일정한 유량으로 측정기에 주입하여 악취센서 의 성능평가를 진행하였다.

VOCs 악취센서의 최소검출한도 실험조건은 온도 25

o

C에서 습도 변화(50%, 65%, 75%)에 따라 최소감 지농도보다 낮은 5 ppb에 대하여 업체별 센서 측정기 를 대상으로 5회 반복실험을 수행하였다(Han et al., 2012).

악취센서의 감지 특성을 분석하기 위하여 초고순도 질소가스(99.9999%)를 이용하여 온·습도 조절 실험을 각각 3회씩 진행하였다. 온·습도 셋팅 실험은 기기 내 부 및 계절적인 온도 변화 요인을 고려하여 상대습도 50% 에서 온도 0~40

o

C 범위로 설정하였으며, 실험 결 Table 1. Properties of odor sensor in Korea

Corp. Odor sensor Measuring item Reaction time (sec)

Measuring cycle (sec)

Proper injection flow (LPM)

A TVOC 30 20 0.1

B NH

3

, H

2

S, TVOC ≤ 30 10 0.1

C NH

3

, H

2

S, TVOC,

complex odor intensity

NH

3

: 40 H

2

S : 35 TVOC : 3

3 0.5

D NH

3

, H

2

S, TVOC,

complex odor intensity 30 3 0.3

(4)

Table 2. Test method of VOCs odor sensor-specific performance

Item Contents Test method

Minimum detection limit

Testing the minimum detection concentration by selected the best three sensors

- TVOC

- Test using each manufacturer's specific sensors - Test temperature: room temperature (around 25

o

C)

- Based on the predetermined minimum level detected by the manufacturer to present increased scale repeat test

- 3 times of the detection limit of the repeat test stability test

Temperature stability

Temperature stability is tested in the air, and hold the impact

- Test using the manufacturer-specific sensors with respect to the four species of stink substance

- Temperature : 0, 25, 40

o

C

- Relative humidity : 50% RH outside

- Concentration : low, middle and high concentrations (depending on the sensor type)

Humidity stability

Humidity stability is tested in the air, and hold the impact

- Test using the manufacturer-specific sensors with respect to the four species of stink substance

- Temperature : 25

o

C

- Relative humidity : 50, 65, 75% RH

- Concentration : low, middle and high concentrations (depending on the sensor type) - TVOC is isobutylene, toluene, xylene, utilizing the stylene

- The sensor module is tested by making the sensor module separately but if you use the instrument provided by the manufacturer, not supplied by the manufacturer

Table 3. Humidity control method of VOCs odor sensor Temperature

(

o

C)

Humidity

(%) Method

25

75

I) Impinger also connect two of distilled water into 150 mL in parallel II) Impinger succeed ultra-high purity nitrogen gas (99.9999%) by 0.8 LPM

III) Ultra-high purity nitrogen gas passed through the impinger 6 L filling the 10 L bag to capacity and odorless

IV) Finally verify the final humidity by hygrometer to the odorless bag

65

I) Humidity 75% gas : same as the above method II) Humidity 30% gas

- 0.8 LPM of ultra pure nitrogen gas passed the silicagel

- Ultra-high purity nitrogen gas passed through a silicagel capacity 10 L 6 L filled in the odorless bag

- Check the final odorless bag inside humidity hygrometer should III) Humidity 65% gas: ① 6 L + ② 1.8 L = ③ 7.8 L

50 Humidity 65% Gas (6 L) + Humidity 30% gas (4 L) = Humidity 50% gas Table 4. Temperature control method of VOCs odor sensor

Temperature (

o

C)

Humidity

(%) Method

0

50

Setting temperature 0

o

C, humidity 50% alignment. using temperature and humidity controlled environment chamber

25 Humidity 65% gas (6 L) + Humidity 30% gas (4 L) = Humidity 50% gas

40

I) Room temperature (25

o

C) of distilled water and placing the Atomizer II) Ultra high purity nitrogen gas in the suction box Atomizer with 1.8 LPM III) Ultra-high purity nitrogen gas through the Atomizer 10 L 6 L filling the bag to

capacity and odorless

IV) Back into the environment, the chamber is filled with the odor 6 L also the temperature was adjusted to 40

o

C

V) Temperature by using a hygrometer according to the 40

o

C when the check box for

the final humidity

(5)

과 상대습도 50%에서 온도가 0

o

C, 25

o

C, 40

o

C 일 경 우 평균 상대습도는 Table 5에서와 같이 각각 45%, 53%, 50.2%로 나타났다. 습도 셋팅 실험 결과 온도 25

o

C에서 상대습도 50%, 65%, 75% 일 경우 평균 상 대습도는 Table 6에서와 같이 각각 53%, 63.3%, 74.4% 로 나타났다.

VOCs 악취센서의 온도의 안정성 실험조건은 습도 50%에서 온도 0

o

C, 10

o

C, 25

o

C, 40

o

C로 설정한 상태에 서 실험하였으며, 습도의 안정성 실험조건은 온도 25

o

C 에서 습도 50%, 65%, 70%, 75%를 설정한 상태 에서 실험하였다. VOCs 악취농도는 5 ppb, 50 ppb, 200 ppb, 500 ppb의 4단계로 구분하여 VOCs 악취센서 를 대상으로 5회 반복실험을 수행하였다(Kim et al., 2008; NIER, 2011).

3. 연구결과 및 고찰

3.1 VOCs 악취센서의 최소검출한도

온도 25

o

C에서 습도에 따른 VOCs 악취물질 가스센 서의 최소검출한도를 Fig. 2에 나타내었다. 광이온화식 가스센서 방식을 이용하는 VOCs 물질의 최소감출한 도는 isobutylene의 경우 습도가 50%일 때 5 ppb에서 4개 제조사 중 3개 제조사에서 표준편차율은 6.9%, 15.6%, 11.0%로 나타났고, 습도가 65%일 때 40.4%, 14.4%, 12.1% 로 나타났으며, 습도가 75%일 때는 36.5%, 39.1%, 44.9% 로 나타나 5 ppb에서 감지가 가 능한 것으로 나타났으나, 습도가 75%일 때는 표준편 차율이 30% 이상으로 이를 보완할 필요가 있는 것으 로 나타났다.

Toluene 의 최소검출한도는 습도가 50%일 때 5 ppb Fig. 1. Overview of odor sensor measuring performance evaluation experiments.

Table 5. Result of temperature setting test of VOCs odor sensor Condition of

temperature and humidity Result

Temp. Hum. Temp. Hum. (1st) Hum. (2nd) Hum. (3rd) Mean 0

o

C

50%

0

o

C 45% 44.7% 44.7% 45%

25

o

C 25

o

C 53.2% 52.7% 53% 53%

40

o

C 40

o

C 51.6% 51.3% 51% 50.2%

Table 6. Result of humidity setting test of VOCs odor sensor Condition of

temperature and humidity Result

Temp. Hum. Temp. Hum. (1st) Hum. (2nd) Hum. (3rd) Mean 25

o

C

50%

25

o

C

53.2% 52.7% 53% 53%

65% 63% 61.8% 65% 63.3%

75% 72.9% 75.4% 75% 74.4%

(6)

에서 4개 제조사 중 3개 제조사에서 표준편차율은 25.3%, 14.4%, 7.7%로 나타났고, 습도가 65%일 때 15.5%, 15.6%, 7.7%로 나타났으며 습도가 75%일 때 의 표준편차율은 54.8%, 53.8%, 11.1%로 나타나 5

ppb 에서 감지가 가능한 것으로 나타났으나, 습도가

75%일 때는 표준편차율이 50% 이상으로 나타나 이를

보완할 필요가 있는 것으로 나타났다. Xylene의 최소

검출한도는 습도 50%일 때 5 ppb에서 4개 제조사 중

Fig. 2. Minimum detection limit of VOCs odor sensor.

(7)

3 개 제조사에서 표준편차율은 9.1%, 9.5%, 5.8%로 나 타났고, 습도가 65%일 때 20.1%, 17.8%, 12.1%로 나 타났으며, 습도가 75%일 때의 표준편차율은 24.4%, 29.3%, 49.3%로 나타나 5 ppb 농도에서도 감지가 가 능한 것으로 나타났으나, 습도가 75%일 때는 센서 출 력값이 불안정하게 나타났다. Stylene의 최소검출한도 는 습도 50%일 때 5 ppb에서 4개 제조사 중 3개 제조 사에서 표준편차율은 24.6%, 17.9%, 12.9%로 나타났 고, 습도가 65%일 때 7.9%, 14.3%, 7.7%로 나타났으 며, 습도가 75%일 때의 88.3%, 19.3%, 18.2%로 나타 나 5 ppb에서 감지가 가능한 것으로 나타났으나, 습도 가 75%일 때는 센서 출력값이 불안정하게 나타났다.

3.2 VOCs 악취센서의 온도의 안정성

VOCs 악취센서의 온도의 안정성 실험 결과를 Fig.

3 에 나타내었다. VOCs 광이온화식 가스센서의 온도의 안정성 실험은 4개사의 악취센서 측정기를 대상으로 실험을 수행하였다. Isobutylene, toluene, xylene 및 stylene 가스센서의 온도의 반응성은 25

o

C 를 기준으로 0~25

o

C 범위에서는 온도가 높아질수록 가스센서의 반 응성이 증가하였으며, 25~40

o

C 온도 범위에서는 온도 에 반비례하여 가스센서의 반응성이 감소하였다. 가스 센서의 온도 안정성은 0~10

o

C 온도 범위에서는 악취 센서의 출력값이 낮게 출력되었으며, 25~40

o

C 온도 범 위에서는 제조된 악취가스 농도값과 비교적 근사한 값

Fig. 3. Temperature stability of VOCs odor gas sensor. Fig. 3. continued

(8)

으로 나타났다. 온도별 VOCs 악취센서의 농도의 표준 편차는 4개 제조사 중 3개 제조사에서 온도 10~40

o

C 범위, VOCs의 농도 50~500 ppb 범위에서 농도 표준편 차율이 10% 이하로 많이 나타났다. 따라서, 광이온화 식 가스센서의 센싱 가능한 운전 온도 범위는 25~40

o

C 로 판단되며, 온도가 낮을 때는 센서 출력값이 불안정 한 것을 확인할 수 있었으며 또한, 가스센서의 센싱 가 능한 VOCs의 농도 범위는 50 ppb 이상에서 정확성이 높게 나타남을 알 수 있었다.

3.3 VOCs 악취센서의 습도의 안정성

VOCs 악취센서의 습도의 안정성 실험 결과를 Fig.

4 에 나타내었다. VOCs 물질 중 isobutylene, toluene, xylene, stylene 을 측정하는 광이온화식 가스센서의 습 도 안정성은 4개사 VOCs 악취센서 측정기의 출력값 은 습도 50~65%에서 제조된 악취가스 농도값과 근사 하게 나타나는 것을 확인할 수 있었다. 그러나 습도 70~75% 에서는 악취센서 출력값이 제조된 악취가스 농 도값보다 높거나 또는 낮게 나타나는 경향으로 보였다.

따라서 악취센서의 감지 가능한 습도 범위는 50~65%

였으며, 습도가 65% 이상일 때 악취센서 출력값은 불 안정함을 확인할 수 있었으며, 습도별 VOCs 악취센서 의 농도의 표준편차율은 습도가 75%일 때 약간 높게 나타났다.

Fig. 4. Humidity stability of VOCs odor gas sensor. Fig. 4. continued

(9)

4. 결 론

본 연구에서는 4개 업체의 VOCs 악취센서 측정기 의 성능평가 항목인 최소검출한도, 온도의 안정성 및 습도의 안정성 실험을 실시하였다.

광이온화식 가스센서 방식을 이용하는 TVOC의 경 우 5 ppb에서도 감지가 가능한 것으로 나타났으며 습 도가 75%일 때는 센서 출력값이 불안정하게 나타났다.

광이온화식 가스센서의 센싱 가능한 온도 범위는 25~40

o

C 였으며, 온도가 낮을 때는 센서 출력값이 불안 정한 것을 확인할 수 있었으며, 적정 온·습도에서의 안정적인 악취센서 출력값의 출력을 위해 온·습도 전 처리 후 악취센서 출력값 테스트를 수행한 결과 습도 를 50%로 조절한 후의 센서 출력값은 제조된 악취 농 도값과 유사하게 출력되는 것을 확인할 수 있었으며, 온도를 25

o

C 로 가열 후의 센서 출력값은 제조된 악취 농도값과 유사하게 출력되는 것을 확인할 수 있었다.

VOCs 악취센서 측정기의 온·습도 안정성은 측정대 상 물질 모두 온도 25~40

o

C, 상대습도 50~65%에서 센 서 출력값이 안정적으로 나타났으며, 온도가 낮거나 습 도가 높은 경우 악취센서 출력값이 불안정하게 나타났 다. 또한, 적정 온·습도 조건에서 가스센서의 센싱 가 능한 VOCs의 농도 범위는 50 ppb 이상에서 정확성이 비교적 높게 나타남을 알 수 있었다. 따라서 VOCs 악 취센서의 안정적인 운영을 위해서는 온·습도 보정 등 의 전처리시스템 도입을 통해 측정시 적정 온·습도 조 건(25~40

o

C, 50~65% RH)를 유지하면서 주기적으로 농도를 교정하면서 악취센서를 운영할 필요가 있는 것 으로 판단된다. 그리고 향후 VOCs 악취센서 측정기의 측정 온·습도 조건에서 측정된 데이터에 대한 표준 농 도와의 검증 등을 통하여 농도 구간별 VOCs 측정데이 타의 정확성 향상도 고려해 봐야 할 것으로 판단된다.

References

Gong B. J., Hong Y. D., Seo S. J., Kim Y. H., Han J. S., Lim J. H., Lee D. W., Hong J. H., 2015. Reliability

evaluation of odor sensor, Journal of Odor and Indoor Environment 14(3), 167-174. (in Korean with English abstract)

Han, J. S., Lim, Y. J., Park, S. J., 2012. A study on the calculation methods of odor threshold value of the specified offensive odor substances. Korean Journal of Odor Research and Engineering 11(1), 24-33. (in Korean with English abstract)

Heo, H. S., Kim, S. T., Hong, S. J., Choi, I. H., 2006.

Application of gas sensor for real-time odor monitoring system.

Kim, S. T., Heo, H. S., Choi, I. H., Kim H. S., 2008. The calibration of odor sensor by n-butanol, Spring Conference of Korean Society for Atmospheric Environment, 249-250.

Kim, S. T., Im, J. J., Bak, S. H., Jo, Y. J., 2012. The study on improvement of the fatigue phenomenon of odor gas sensor, Fall Conference of Odor Research and Engineering, Seoul, 201-203.

Kim Y. H., Kim S. T., Kim H. S., Ga M. H., 2010a. The response characteristics of odorous sensors to major odorous compounds, Conference of odor Research and Engineering, Cheongju, 48-53.

Kim Y. H., Kim S. T., Kim H. S., Ga M. H., 2010b. The correlation between olfactory results and sensor responses with the odor sources, Fall Conference of Odor Research and Engineering, Korean Society of Odor Research and Engineering, Incheon, 173-178.

Ministry of Environment (ME), 2014. Odor Standard Method.

Ministry of Environment (ME), 2015. The study of mid and long term policy direction of odor control system.

National Institute of Environmental Research (NIER), 2011.

The study of proficiency testing for odor mixture.

National Institute of Environmental Research (NIER), 2014.

Metropolitan landfill odor monitoring research (II).

National Institute of Environmental Research (NIER), 2015.

Establishing improvement ways to efficiently manage odor

- Examining validity of the odor measuring instruments and

automatic odor taking instruments -.

수치

Table 3. Humidity control method of VOCs odor sensor Temperature ( o C) Humidity(%) Method 25 75
Table 5. Result of temperature setting test of VOCs odor sensor Condition of
Fig. 3. Temperature stability of VOCs odor gas sensor. Fig. 3. continued
Fig. 4. Humidity stability of VOCs odor gas sensor. Fig. 4. continued

참조

관련 문서

In order to analyze thermal stability and capacity loss according to the temperature of the battery cell by applying different C-rate discharge and

In this study, the performance characteristics of a two-stage CO 2 system with two-different evaporator temperature have been analyzed according to outdoor

This research shows that there are the success factors of foreign hidden champions such as leadership and goals, self production, high-performance

The data from the questionnaire survey were analyzed to prove the effects of Myung Power Therapy on such scales of the relaxation of pain as improvement

The materials used for this research are the average temperature, maximum temperature, minimum temperature, precipitation, humidity, and sunshine duration in Honam

Conclusions: This study suggests that psychological health factors such as stress perception, depression and suicidal ideation are related to the quality of sleep

(b) Island formation starts due to an influx of the cooler part of the plasma outside the inversion radius through the magnetic reconnection as soon as the

Improvement of the Performance and Stability of Oxide Semiconductor Thin-Film Transistors Using Double-Stacked Active Layers.. Metal oxide semiconductor