• 검색 결과가 없습니다.

Heat Exchangers for Gas Turbine Cycles and Thermal Management

N/A
N/A
Protected

Academic year: 2021

Share "Heat Exchangers for Gas Turbine Cycles and Thermal Management"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Heat Exchangers for Gas Turbine Cycles and Thermal Management

(롤스로이스 기술개발 동향)

Rory Stieger (Rolls-Royce) ABSTRACT

Rolls-Royce is a global company producing advanced power systems for use on land, at sea and in the air. In order to develop competitive products and services, Rolls-Royce invests in technology, infrastructure and capability with much of the research carried out in a global network of University Technology Centres, such as the UTC in Thermal management at Pusan National University.

Heat exchangers and thermal management play a critical role in today's gas turbine engines, maintaining the fuel and oil temperatures within the correct operational range. Future products are likely to place an increased duty on the thermal management system and thus require advances in heat exchanger design, installation and manufacturing.

Heat exchangers further have the potential to play a vital role in Advanced Cycle Gas Turbine products. The Intercooled and recuperated WR21 marine gas turbine engine recently entered service with the Royal Navy and is delivering very attractive fuel burn in service. The development of an advanced cycle aero-engine is a significantly greater challenge, requiring better understanding of compact and light weight heat exchanger surfaces, novel installations and ducting systems and may required novel manufacturing techniques to achieve the volume, weight and cost necessary to realise a viable advanced cycle gas turbine aero-engine.

한국추진공학회 2011년도 춘계학술대회 논문집 pp.465 2011 KSPE Spring Conference

- 465 -

참조

관련 문서

Also, the design of an optimal heat sink requires a complete knowledge of all heat transfer characteristics between the heat source and the ambient air

The desalted crude is then sent to another series of heat exchangers (6 10) for heating to 427 o F then sent to exchangers (6-10) for heating to 427 o F, then, sent

▪ Local temperature of PMSM can be calculated through thermal resistance model and heat generation model, presenting the cooling performance thermal

For this reason, in this study, comparing the traditional manufacturing process and relatively high temperature of exhaust gas heat and CO2 laser

A PID control with Feedfoward Controller for Controlling Fluid Temperature in Heat Exchanger.. 지도교수

Fig.11 Temperature histories of the hot side and cold side heat exchangers according to time with speaker power(10W).. Fig.12 Temperature histories of the hot

• Heat conduction with a electrical heat source, a nuclear heat source, a viscous heat source, and a chemical heat source.. • Heat conduction

– Reversible cyclic process with Ideal gas – Maximum efficiency of a