Grindability of Ti-Xwt%Cu Alloys for Dental Applications

Jae-Seok Ahn

Dept. of Dental Lab. Korea University Ansan Hospital. Gojan1dong 516 Danwon Ansan Kyung-ki , South Korea.

This study evaluated the grindability of series of Ti-Cu alloys in order to develop a Ti alloy with better grindability than commercially pure titanium(CP Ti). Experimental Ti-Xwt%Cu alloys(X=2, 5, 10) were made in an argon-arc melting furnace. Slabs of experimental alloys were ground using a SiC abrasive wheel on an electric handpiece at circumferential speed(15000, 30000rpm) by applying a force(250, 300gr). Grindability was evaluated by measuring the amount of metal volume removed after grinding for 2 minutes. Data were compared to those for CP Ti and Ti-6wt%Al-4wt%V alloy.

From results, It was observed that the grindability of Ti-Cu alloys increased with an increase in the Cu concentration compared to CP Ti, particularly the 10wt%Cu alloy exhibited the highest grindability at all speeds.

By alloying with Cu, the Ti exhibited better grindability at high speed. The continuous precipitation of Ti 2 Cu among the -matrix grains made this material less ductile and facilitated more effective grinding because small segments more readily formed. The Ti-10wt%Cu alloy has a great potential for use as a dental machining alloy.

Key words : Ti-Cu alloys, Grindability, commercially pure titanium(CP Ti), Ti-6wt%Al-4wt%V alloy, Precipitation of Ti

2

Cu, The -matrix grains

[Abstract]

(2)

32

(3)

33

(4)

34

(5)

35

(6)

36

참조

관련 문서

These results suggest that, the ZrN coated Ti-Nb alloy is a good corrosion resistance for dental implant compared with non-coated Ti-Nb alloy... The

The surface of untreated Ti, SLA treated Ti, and AA plasma polymerized SLA/Ti were also examined for their proliferation and differentiation of

F F Fi i ig g g.. C) 처리한 시편의 미세조직을 관찰한 것이다.. 950× 10 -6 ㎂/㎠ 이므로 Cp-Ti 의 시편에서 부식성이 다소 양호하게 나타났다.이러한 부식특성의 차이는 Cp-Ti

Figure 4.15 Measured proportional constant A as a function of Cu content in Al-Si-Cu ternary alloys cast with

Null hypotheses of this study was there is no difference in root canal length determination between conventional and heat-treated Ni-Ti files by 2

Consequently, Zr-Cu binary alloys have the potential to be used as biomaterials with nullifying magnetic properties for magnetic resonance imaging diagnosis and

 KAERI tested FSW between 10 mm thick CSC Cu coating and normal cu plate to get a sealing method of a disposal canister.  Before the FSW test, Bead-On test was done on the

이것은 이용허락규약 (Legal Code) 을 이해하기 쉽게 요약한 것입니다. 귀하는 원저작자를 표시하여야 합니다.. Physical properties of titanium and titanium