SRI Gas Chromatographs
• Value-priced – Typically half the price of comparable units from other manufacturers
• Versatile – Choose from a large selection of GC detectors and injectors
• Compact Size – Much smaller than other GCs, can be shipped as airline baggage
• PC Programmable – FREE PeakSimple™ data control software included
• Convenience – Many pre-confi gured units available
• Protected – Backed by a 2-year warranty and FREE technical support
Enjoy the convenience of ordering preconfi gured systems from pages 445-446, or confi gure a system to meet your specifi c needs from components from pages 447-449.
SRI GCs are built on one of four chassis. Choose the:
Model 8610C
– for performance and maximum fl exibility.
Model 310
– for economy and compact size Model 110
– allows for the mounting of extra detectors Model 410
– a rack-mounted version of the Model 310 used for 19-inch industrial rack systems.
GC Systems
SRI GC Specifi cations
SRI GC Model: 8610C 310
Temperature: Ambient to 400ºC Ambient to 400ºC Programmable: Yes, Multiple Steps Yes, Multiple Steps Oven Inches: 7.5"W x 7.5"D x 3"H 5"W x 5"D x 3"H Oven Metric: 19.1 x 19.1 x 7.6cm 12.7 x 12.7 x 7.6cm Capillary Column: 7" Cage Capillaries 4" Cage Capillaries Packed Column: 1/4" or 1/8" 1/8"
Detectors: Up to 4 Up to 4
Inlets: On-Column, Up To 5 On-Column, 1 inlet Dimensions Inches: 18.5" x 14.5" x 13" 12.5" x 14.5" x 13"
Dimensions Metric: 47 x 36.8 x 33cm 31.7 x 36.8 x 33cm Weight: 45-80lbs (20-36kg) 40-70lbs (18-32kg)
SRI GC Specifi cations
SRI GC Model: 110 410
Temperature: 200°C Max (transfer Line) Ambient to 400°C
Programmable: n/a Yes, Multiple Steps
Oven Inches: n/a 5"W x 5"D x 3"H
Oven Metric: n/a 12.7 x 12.7 x 7.6cm
Capillary Column: n/a 4" Cage Capillaries
Packed Column: n/a 1/8"
Detectors: Up to 4 Up to 4
Inlets: Heated Transfer Line Choose 1 of 4 Dimensions Inches: 8.5" x 14.5" x 13.5" 12.5" x 14.5" x 13"
Dimensions Metric: 21.6 x 36.8 x 34cm 31.7 x 36.8 x 33cm Weight: 40-70lbs (18-32kg) 40-70lbs (18-32kg)
Model 8610C Model 310
Model 110 Model 410
Contact Alltech Tech Support:
Email: tech_service@alltechemail.com Online: www.alltechWEB.com
Alltech Technical Service
Ordering your SRI GC through Alltech gives you access to Alltech’s highly regarded Technical Service organization. Our staff of technical support chemists and product specialists are available to help you choose the SRI gas chromatograph, options, and accessories to best suit your needs. They can also help you choose the products from our complete line of Packed GC Columns, Capillary Columns, and GC Accessories that will complete your GC system.
SRI Systems are CE, TUV, GS, and NRTL approved.
SRI manufactures all instruments in compliance with EN 61010 standards for laboratory equipment.
Instruments come with a two-year warranty.
Every SRI GC Comes Complete with:
• Single on-column injector for 0.53mm i.d. capillary or 1/8"
packed columns or injectors of choice
• Electronic pressure control for all gases
• Temperature programmable oven - programmable in multiple segments
• Digital pressure readout
• Digital temperature readout - ambient to 400°C
• Built-in data system with PeakSimple™ for Windows® software
• Operator’s manual
• 10µL syringe and spare septa
• Heavy duty reusable shipping container. Shipped easily by common carriers (UPS or Fed EX)
Contact your Alltech offi ce or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech offi ce or distributor for current or local prices.
444
444 445 445
GC Systems
Preconfi gured SRI GCs
Enjoy the Convenience of Ordering a System Already Optimized for Your Application
Preconfi gured GCs are designed with inlet systems, detectors, and accessories required for a specifi c
application. The preconfi gured GCs are also supplied with an internal data acquisition system and PeakSimple™ for Windows® software to control the GC and acquire and analyze the data.
Educational GC – 310 Chassis
• Allows for hands-on instruction of GC principles Gasless with CCD (built-in air compressor)
• Operates on air carrier gas
• Standard on-column injector
• Detects combustible (hydrocarbon) molecules
• Packed GC column included - 1 meter Hayesep-D
MODEL 310 WITH CCD*
DESCRIPTION
P110VART NO. 220V
PART NO. PRICE
Gasless w/CCD with cooling 31001105 310502 Gasless w/CCD without cooling 8611252 8611305
TCD System (fast and manual cool down)
• Universal detector sensitive from 100% to 200ppm
• Can analyze room air, human breath
• Packed GC column – 1 meter silica gel
MODEL 310 WITH TCD*
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
Model 310 with TCD 8610001 310501
FID System
• Carrier and combustion gas
• 1 meter silica gel
MODEL 310 WITH FID*
DESCRIPTION
P110VART NO. 220V
PART NO. PRICE
Model 310 FID with cooling 8611251 8611306
Basic Capillary FID GC – 8610C Chassis
• Designed specifi cally for capillary GC analysis
• Hydrocarbon selective from 100% to 1ppm
• Built-in air compressor
• 30-meter x 0.53mm capillary column
BASIC CAPILLARY FID GC
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE Basic Capillary FID GC 8610523 8610524
Multiple Gas Analyzer – 8610C Chassis
Separates H2, O2, N2, CH4, CO2, and Hydrocarbons.
Model 1 – Fixed Gases and C1 to C6 Hydrocarbons
• Two columns – MoleSieve 13x and silica gel
• Sensitivity for CO and CO2 to ppm level
• 10-port gas sampling automatic valve and loop
MODEL 1 – MULTIPLE GAS ANALYZER
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE Model 1 w/TCD Single Channel 8610022 8610512
Model 1 w/TCD/FID* 8610023 8610513 Model 1 w/TCD/HID* 8610501 8610514
Models 1 and 2 Plus Sulfur
Multiple gas and sulfur analysis in one unit. Detects low sulfur concentrations.
• TCD, FID-methanizer and FPD/FID detectors
• Uses just 1 gas sampling valve with silcosteel
• 2-meter MoleSieve and silica gel columns
• 60-meter capillary column
• Built-in, “whisper quiet” air compressor
MODELS 1 AND 2 PLUS SULFUR – MULTIPLE GAS ANALYZER
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE Model 1 Plus Sulfur** 8611271 8611325
Model 2 Plus Sulfur** 8611274 8611307
Model 2 Fixed Gases and C1 to C20 Hydrocarbons
• Heated 10-port gas sampling valve (electrically actuated)
• Column switching
• Also measures water and alcohol
• Two packed GC columns
MODEL 2 – MULTIPLE GAS ANALYZER
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
Model 2 w/TCD 8610503 8612232
Model 2 w/TCD/FID/Methanizer 8610504 8612233
Model 2 w/TCD/HID 8611273 8610514
* CCD – catalytic combustion detector
* TCD – thermal conductivity detector
* FID – fl ame ionization detector
*Four Channel Data System
**Four Channel PeakSimple™ Data System
Sulfur GC – 8610C Chassis
For the analysis of H2S in natural gas, total reduced sulfur analysis, mercaptans, and sulfur containing pesticides.
• FID/FPD combination detector
• Built-in air compressor
• 1 meter PTFE Hayesep® D column
• 10-port gas sampling valve with nickel loop
SULFUR GC DESCRIPTION
PART110V NO. 220V
PART NO. PRICE
Sulfur GC* 8610525 8610517
*Four Channel PeakSimple™ Data System
Multiple gas and sulfur analysis in one unit. Detects Multiple gas and sulfur analysis in one unit. Detects
Contact your Alltech offi ce or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech offi ce or distributor for current or local prices.
446
446 447 447
GC Systems
BTU Gas Analyzer – 8610C Chassis
For the analysis of natural gas and computing the BTU rating. Measures nitrogen, methane, carbon dioxide, ethane, water, propane, iso and normal butanes, iso and normal pentanes, and C6 plus hydrocarbons.
• Thermal conductivity detector
• 10-port gas sampling valve
• Packed GC column
• 30m capillary column
BTU GAS ANALYZER
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
BTU Gas Analyzer 86103070 8610518
Environmental GC – 8610C Chassis
Ideal for laboratory or fi eld-testing applications where space, price, and versatility are crucial. The Environmental GC is designed for EPA methods 5030, 5030/5035. It will easily generate certifi cation quality data for EPA Methods 8021, 8010, 8015, TO-14, and many others.
• FID, PID, and DELCD detectors
• Equipped with the method 5030/5035 compliant purge and trap
• Built-in air compressor
• 60m capillary column
ENVIRONMENTAL GC
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
Environmental GC* 8610058 8612258
PCB GC – 8610C Chassis
Detects PCBs in soil and other solids. Also used for analysis of pesticides, PAHs, JP-4, Kerosene, and diesel.
Accepts 1 gram samples.
• FID/DELCD combination detector
• Built-in thermal desorber
• Built-in air compressor
PCB GC
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
PCB GC* 8611265 8611308
BTEX GC – 8610C Chassis with FID/PID
Designed for the analysis of benzene, toluene, ethylbenzene, and xylenes.
• Method 5030/5035 compliant purge and trap
• Built-in air compressor
• 60m capillary column
Preconfi gured SRI GCs
*Four Channel PeakSimple™ Data System
*Four Channel PeakSimple™ Data System
BTEX GC
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
BTEX GC* 8612250 8610510
5030/5035 Compliant* Upgrade 8611267 8611309
*Four Channel PeakSimple™ Data System
TO-14 GC – 8610C Chassis
Designed for the TO-14 or an ambient air analysis.
• PID and FID/DELCD detectors
• Dual trap sample concentrator
• Built-in air compressor
• Vacuum pump interface
• 60m capillary column
TO-14 GC
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
TO-14 GC* 8610502 8610515
*Four Channel PeakSimple™ Data System
Mud-Logging GC – 8610C Chassis
Reports the total hydrocarbons of a gas stream as well as performing separations.
• Flame ionization and catalytic combustion detector
• Packed GC column
• Built-in air compressor
• 10-port gas sampling valve
MUD-LOGGING GC
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
Mud-Logging GC* 8610500 8610511
*Four Channel PeakSimple™ Data System
TOGA GC System – 8610C Chassis
This portable unit determines the gases dissolved in transformer oil.
• HID and /or TCD detectors
• MoleSieve and silica gel packed columns
• Syringe pump for industry standard 50mL syringes
• Dual 10-port gas sampling valves
• Gas extraction loop
TOGA GC SYSTEM DESCRIPTION
PART110V NO. 220V
PART NO. PRICE
TOGA w/TCD Detector 8611326 8611327 TOGA w/HID Detector 8611328 8611329 TOGA w/TCD and HID Detector 8611330 8611331
PCB GC – 8610C Chassis PCB GC – 8610C Chassis
Detects PCBs in soil and other solids. Also used for
Detects PCBs in soil and other solids. Also used for This portable unit determines the gases dissolved in This portable unit determines the gases dissolved in
Contact your Alltech offi ce or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech offi ce or distributor for current or local prices.
446
446 447 447
GC Systems
SRI Chassis
Choose From Basic Chassis 310, 8610C, or from Optional Chassis 110 or 410.
When picking chassis you need to select chassis with a built in PeakSimple™ A/D that allows fro the operation of the unit. With multiple detectors, valves and other options, more channels are needed to operate the GC.
MODEL 310 CHASSIS
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE With 1-Channel PeakSimple™ 8611249 8611250
With 4-Channel PeakSimple™ 3100100 3100122 With 6-Channel PeakSimple™ 8611257 8611258
MODEL 110 WITH DETECTORS INSTALLED
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
With CCD 8611243 8611312
With DFPD 8611240 8611313
With ECD 8611236 8611314
With FID 8611234 8611315
With FID/DELCD 8611244 8611316
With FID/FPD 8611242 8611317
With FID/PID 8611247 8611318
With FPD 8611239 8611319
With HID 8611237 8611320
With NPD 8611235 8611321
With PID 8611238 8611322
With PID/FID/DELCD 8611246 8611323
With TCD 8611233 8611324
MODEL 8610C CHASSIS*
DESCRIPTION
PART110V NO. 220V
PART NO. PRICE
With 1-Channel PeakSimple™ 8611275 8611276 With 4-Channel PeakSimple™ 8610102 8612202 With 6-Channel PeakSimple™ 8611285 8611286
Model 110
The model 110 is a stand alone detector chassis. It can be mounted with up to 4 detectors.
MODEL 410 RACK MOUNT UNITS DESCRIPTION
PART110V NO. 220V
PART NO. PRICE
With 1-Channel PeakSimple™ 8611259 8611260 With 4-Channel PeakSimple™ 8611261 8611262 With 6-Channel PeakSimple™ 8611263 8611264
Model 410
The model 410 unit uses the Model 310 chassis but fi ts into a 19" rack mount.
BASIC MODEL 110
DESCRIPTION 110V
PART NO. 220V
PART NO. PRICE
Without Detectors 8611231 8611232
Customizing Your GC?
SRI offers many different GC platforms from which you can develop the type of GC you desire. Select the basic GC platform and then add the injection ports, ovens, detectors, and PeakSimple™ data system you desire.
Customize Inlet Systems, Detectors, and Accessories to Suit Your Specifi c and Unique Requirements.
From the list below, follow the basic instructions to confi gure your custom GC. On either chassis, you can order as many as four detectors. On the Model 310 chassis, you are limited to one sample inlet system;
on the Model 8610C you may order as many as fi ve.
If you need a gas sampling valve, you must order a Model 8610C. If you have any questions, contact our Technical Support group.
How to Build a Custom GC:
1. Choose the chassis you will need with the appropriate channels. (page 447)
2. Choose detectors (as many as 4). (page 448) 3. Choose inlet system (as many as 5 for 8610C, 1
for 310). (page 448)
4. Choose optional accessories. (page 449)
Contact Alltech Tech Support:
Email: tech_service@alltechemail.com Online: www.alltechWEB.com
Need Technical Assistance?
* Model 8610C with dual ovens are available upon request.
The model 110 is a stand alone detector chassis. It The model 110 is a stand alone detector chassis. It
Contact your Alltech office or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech office or distributor for current or local prices.
448
448 449 449
SRI Inlet Systems
Every SRI GC is equipped with an unheated on- column inlet system. On a Model 310 chassis, you can replace that with any one of the other four inlet systems available – headspace, split/splitless, purge & trap, and flash. On a Model 8610C chassis, you can mount any of the inlet systems to a total of five.
On-Column Inlet Systems
Suitable for 0.53mm capillary and 1/8" packed columns. Includes EPC carrier gas controller & molecular sieve filter.
GC Systems
SRI Detectors
The SRI GC allows you to choose the detector(s) you want installed. The chassis can accommodate as many as four detectors to give you maximum flexibility. Table 1 includes a listing of the detectors that are available for your SRI GC. The table shows the typical detection limits for each detector along with their common applications.
Table 1 – Detector Specifications
DETECTOR SELECTIVITY SENSITIVITY (APPROX.) CCD Hydrogen and hydrocarbons 500ppm
TCD Universal 200-500ppm
FID Hydrocarbons 1ppm
DELCD Chlorinated and brominated
molecules 10ppb
FID/DELCD Hydrocarbons, chlorinated and brominated molecules 10ppm HID Universal with exception of
neon 10ppm
PID Aromatics and molecules with double carbon bonds 10ppb
NPD Nitrogen and phosphorus 10ppm
NPD/DELCD Nitrogen, phosphorus,
chlorinated and brominated 100ppb TID Nitro functional groups (TNT
etc.) 1ppb, 50ppb
ECD Electronegative compounds 10ppb RGD Reducing gases (such as H2
and CO) 10ppb
FPD Sulfur and phosphorus 200ppb and 10ppb
FPD/FID Sulfur, phosphorus, and
hydrocarbons 200ppb, 10ppb,
and 100ppm Dual FPD Sulfur and phosphorus
simultaneously 200ppb and 10ppb
FID Dual FPD Hydrocarbons, sulfur,
phosphorus simultaneously 100ppm, 200ppb, and 10ppb
SRI GC DETECTORS (CHOOSE UP TO 4)
DESCRIPTION PART NO. PRICE
TCD (Thermal Conductivity) 8690107
FID (Flame Ionization) 8690010
NPD/DELCD (Series Detector) 8611299 NPD (Nitrogen-Phosphorus) 8690015
ECD (Electron Capture) 8690020
PID (Photo-Ionization) 8690040
FPD (Flame Photometric) 8690080
FPD/FID Simultaneous 8691080
DFPD (Dual Flame Photometric) 8690085 DELCD (Dry Electrolytic Conductivity) 86901026
FID/DELCD Simultaneous 8692026
HID (Helium Ionization Detector) 8690030 TID (Thermionic Ionization Detector) 8690017 CCD (Catalytic Combustion Detector) 86902007 RGD (Reduction Gas Detector) 8611293
ON-COLUMN INLET SYSTEMS
DESCRIPTION PART NO. PRICE
Additional On-Column Injector 8690023
Heated Static Headspace Inlet System
Ideal for the analysis of volatiles, especially where the sample matrix is dirty. Sample is heated and injected via a sample loop and gas sampling valve. Vial sleeve can be heated to 90°C. Requires 10-20mL of sample for operation.
HEATED STATIC HEADSPACE INLET SYSTEMS
DESCRIPTION PART NO. PRICE
Heated Static Headspace Injector 8690045
Heated Split/Splitless Injector
Permits the use of narrow-bore capillary columns (0.32mm i.d. and smaller) in either split or splitless modes. Allows 0.53mm capillary columns and 1/8"
packed columns to be used in split, splitless or on- column modes. Injector temperature is adjustable or programmable to 300°C.
HEATED SPLIT/SPLITLESS INJECTOR
DESCRIPTION PART NO. PRICE
Heated Split/Splitless Injector 8690034 Heated Split/Splitless Injector with PTV 8611303
Heated Flash Vaporization Injector
Vaporizes the sample prior to the column. Ideal for desorption of SPME fibers or injection of extremely dirty samples. The injector heater block can be heated to 300°C.
HEATED FLASH VAPORIZATION INJECTOR
DESCRIPTION PART NO. PRICE
Heated Flash Vaporization Injector 8690025
Contact your Alltech offi ce or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech offi ce or distributor for current or local prices.
448
448 449 449
6687
6688 6686
6758 6685
GC Systems
SRI Accessories
SRI 10-Port Gas Sampling Valve
Factory plumbed according to your application specifi cations and tested to guarantee performance.
Available in manual or electrically actuated models. Can only be mounted on the Model 8610C GC.
Thermostatted Valve Oven
Can only be mounted on the Model 8610C GC.
Accommodates 1 or 2 electronically actuated and one manually actuated valve. The oven can be heated to 175°C for electrically actuated valves and autosamplers.
Model 8640 20 Vial Liquid Autosampler
A twenty vial autosampler comes factory installed on the Model 8610C GC. Injection volume is adjustable from 0-3µL. Requires 1mL of sample and an inert gas source at 60psig to operate. One hundred screw cap vials and septa are included. This autosampler is only compatible with the model 8610C GC.
SRI 10-PORT GAS SAMPLING VALVE
DESCRIPTION PART NO. PRICE
10-Port Gas Sampling Valve-Manual 8690063 10-Port Gas Sampling Valve-Electric 8690065
THERMOSTATTED VALVE OVEN
DESCRIPTION PART NO. PRICE
Thermostatted Valve Oven 8690088
MODEL 8640 20 VIAL LIQUID AUTOSAMPLER
DESCRIPTION PART NO. PRICE
Model 8640 20 Vial Liquid Autosampler 8640010
Model 311H 42 Vial Liquid Autosampler
Compatible with the Model 8610C and 310 GCs. Installs via the injection port with a single fi nger tight nut. Injection volume is adjustable from 0-3µL. Requires 1mL of sample and an inert gas source at 60psig to operate. One hundred screw cap vials and septa are included.
MODEL 311H 42 VIAL LIQUID AUTOSAMPLER
DESCRIPTION PART NO. PRICE
Model 311H 42 Vial Liquid Autosampler 8690068
Model H2-50 Hydrogen Generator
• Requires only grocery store quality distilled water
• Convenient small size – 8.5"H x 9.1"W x 9"D
• Gas purity – 99.5%
• Flow rate – 50mL/min at 30psig
• Production rate from full reservoir – 30 hours at
50mL/min or 100 hours at 25mL/min
• External power supply equipped with universal transformer
MODEL H2-50 HYDROGEN GENERATOR
DESCRIPTION PART NO. PRICE
Model H2-50 Hydrogen Generator 86800350
Model H2-50 Upgrade Kit
• Peristaltic pump
• Water level sensor
• 1 month plus continuous operation on 1 gallon of water
• External power supply equipped with universal transformer
H2-50 UPGRADE KIT
DESCRIPTION PART NO. PRICE
Model H2-50 Upgrade Kit 8611290
Spare Desiccant Canister* 8611291
*For Upgrade Kit – Recommended
Method 5035 Compliant Purge & Trap
Ideal for higher level soil samples or soil/methanol extractions. Uses low cost disposable 16mm test tubes which are purged at ambient temperature.
METHOD 5035 COMPLIANT PURGE & TRAP
DESCRIPTION PART NO. PRICE
Method 5035 Compliant Purge & Trap 8690051 Upgrade Purge & Trap 5030/5035 Compliant 8611302
Contact your Alltech offi ce or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech offi ce or distributor for current or local prices.
450
450 451 451
6690 4541
4542
PeakSimple
™for Windows
®• FREE with every SRI gas chromatograph!
• Runs on Windows® 95/98/Me or Windows® NT/2000/XP
• Can be used on a desktop or laptop PC
• Interfaces with GC through available serial port or USB
PeakSimple™ software really lives up to its name. It is simple, fast, and powerful. Each SRI GC comes with a built in data system and the PeakSimple™ software is the interface between your GC and PC. The PeakSimple™ software will run on any PC with a Windows® 95/98/Me or Windows® NT/2000/XP operating system. The software communicates to the GC through an available serial port or USB.
Data Collection
Features:
• Unlimited temperature and event entries – user defi ned temperature and event programs have no size or entry limitations, allowing a “fi ne-tune” for each run.
• Mouse-driven pull-down menus and windows.
• Multiple point calibration curves – Permits exact quantifi cation of sample components in analysis reports.
• Manual and automated integration correction – manipulate baseline and integration during and after run.
• Peak grouping – for PCB’s and TPH analysis.
• ASCII or binary fi le storage – for export to spreadsheets, etc.
• Direct data exchange (DDE) links to other Windows® applications (e.g. Excel™).
• Multi-tasking with other PC applications.
• Automatic calibration at seven concentration levels with six curve fi tting options including straight line, multi-line, parabolic, and quadratic. Choice of area or height calculation for each peak.
• Retention time windows are easily changed with a click and a drag of a mouse.
• Multiple internal standard reference peaks.
• High/Low peak alarms with link to user programs if alarm levels are exceeded.
• Baseline subtraction, peak smoothing, valley deconvolution, peak reverse, drift correction.
• Overlay chromatograms for easy visual comparisons.
• Autosampler queues for unattended operation allows mixed methods, auto-recalibration.
• Batch reprocessing of previously run chromatograms.
PeakSimple™ for Windows® gives you the fl exibility and power to meet all your chromatographic needs.
PeakSimple™ provides for seven calibration points and six different types of calibration; from linear to quadratic.
STAND ALONE SERIAL DATA SYSTEM
DESCRIPTION PART NO.
110V PART NO.
220V PRICE With 1-Channel Serial Port 8612010 86001255
With 4-Channel Serial Port 86002055 86022055 With 6-Channel USB 86006055 86006255
For additional information on the PeakSimple™ Data Systems, request IS021. Also available on our website.
Also Available:
Stand Alone Serial Data System
• Works with GC or HPLC systems
• Comes with PeakSimple™ for Windows® software
• Single, four, or six channel models
Contact your Alltech offi ce or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech offi ce or distributor for current or local prices.
450
450 451 451
Gas Generators – Hydrogen
Hydrogen Generators
To improve safety in your laboratory consider replacing hydrogen cylinders with gas generators.
Not only is it a safe move but a long-term fi nancially benefi cial decision. Most gas generators have a fi nancial payback of a year to a year in a half with an expected life of over fi ve years.
To choose hydrogen generators, base your choice on price, desired options, and the time servicing the units.
The features table below shows the options available with the different manufacturer models.
Auto-Water-Fill – Units with this feature sense when they have low water and open a valve allowing water to be added to the unit. The deionized water source is a separate unit and not included with this option.
Built-in Purifi cation – Gas generators generally have some form of built-in purifi cation. Desiccant purifi ers are commonly used. They have to be changed depending on the unit and fl ow. The second option is a built-in palladium purifi er. These electrical purifi ers work for years with no service needs but add cost to purchase.
The newest option is adsorbent purifi ers that regenerate themselves. They are lower cost than palladium purifi ers and are not as expensive to replace.
Cascading Units – Cascading units involves
connection of multiple generators to a common hydrogen line. Without this option each unit is separately plumbed.
Hydrogen Generators Specifi cations
SRI H250 PARKER CHROMGAS PARKER BALSTON CHRYSALIS II SEPG CHRYSALIS II HPNM Safety Shut Down:
Water Alarms Yes Yes Yes Yes Yes
Leaks Yes Yes Yes Yes Yes
Other Yes Yes Yes Yes
Flow-mL/min (Model) 50 90 (9090) 100 100
160 (9150) 150 (H2-150) 160 160
250 (9200) 300 (H2-300) 250 250
500 (9400) 500 500
800 (H2-800) 1200 (9800)
Pressure Maximum (psig) 35 90 (9800 -100) 60 150 150
Pressure Read Out Yes Yes Yes Yes Yes
Purity 99.90% 99.9995+% 99.99999+% >99.9999% >99.9999%
Desiccant Purifi er Yes Yes Yes
Regenerable Purifi er Yes
Palladium Purifi er Yes (9800) Yes
Water Quality Distilled Deionized NAOH Mix Deionized Deionized
Auto-Water-Fill Yes Yes Yes Yes
Size (Bench Space:)
Width 11" 13" 12" 8 5/8" 8 5/8"
Height 11" 14 3/4" 16.5" 15 3/4" 15 3/4"
Depth 11" 14" 13" 13 3/8" 13 3/8"
Cascading Units No No No CF** CF**
Computer Control No No No RC* RC*
Certifi cation CE/CSA CE/CSA CE/CSA CE/CSA CE/CSA
Flow and Pressure – The units offered all come with different fl ow capabilities and available pressures. Pick the fl ow and pressures needed for your laboratory.
Purity of Gas – Purity requirements are application dependent. The highest purity needed is for carrier gas.
Some units would need oxygen purifi ers to meet carrier gas specifi cations.
Quality of water –The better the quality of water the longer the cell life of the unit. Generators use either distilled, deionized or NaOH/water mixtures. The frequency of adding water is dependent on the fl ow rate of the unit.
Remote Control – This option allows for the remote monitoring and operation of the units by the use of a hand held controller or by connection to a lab computer.
Safety Shut Down – All hydrogen generators incorporate safety shut down features. If a gas line or column breaks only a few hundred cc of hydrogen will escape. This is not enough hydrogen to cause a fi re or explosion.
Size – The most important dimension is width since bench space is hard to fi nd in most labs. Hydrogen generators are not stackable.
* RC = Remote Control ** CF = Cascading Flow
Please request individual datasheet to obtain complete specifi cation and electrical certifi cations.
Contact your Alltech office or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech office or distributor for current or local prices.
452
452 453 453
6689 6765
Gas Generators – Hydrogen
TABLE 2 - MODEL COMPARISONS
1. FUEL GAS SRI PARKER CHROMGAS PARKER BALSTON CHRYSALIS II 2. CARRIER GAS
AND FUEL GAS
# FLOW CC/MIN
MODEL MODEL MODEL MODEL # FLOW CC/MIN
1 40 H250 9090/FID Gas
Station H2-150 100
1 120
2 80
n/a
3 120
9150 160
4 160
H2-300 2 240
5 200
9200 250
6 240
7 280
9400
n/a 500
3 360
8 320
9 360
10 400
4 480
11 440
12 480
13 520
H2-800
n/a
5 600
14 560
15 600
16 640
6 720
17 680
18 720
19 760
7 840
20 800
21 840
9800
22 880
8 960
23 920
24 960
25 1000
9 1080
26 1040
27 1080
28 1120
10 1200
29 1160
30 1200
** Units provided with polyethylene tubing for installation
The auto-water-fill function found on many hydrogen generators requires a pressurized source of DI water. The DI water system allows for continuous operation of the hydrogen generators with auto-water-fill capabilities.
Water is continuously recirculated via a pump through a DI cartridge and the water quality monitored.
The smaller model H-01-C Type 2 DI System is wall mountable and provides up to 4 Liters of purified water in 24 hour. The Model H40-RO+DI System incorporates a reverse osmosis pretreatment system which can provide more than 25 gallons per day of purified water. The water is stored in a 4 gallons storage tank that sits on top of the cabinet.
System Specifications (for both models)
Shipping weight: ~50lbs
Input power to AC adapter at 100/
240 VAC, 50/60 Hz < 2.0amps Power from AC adapter at 12 VDC: < 2.5amps
Acceptable water inlet pressure: 20 min. to 70psig max.
Allowed TDS* in tap water feed: 1,000ppm max.
Purified water flow rate: ~350mL/min max.
Water purity: ~2MΩ-cm (0.5µS/cm) min.
Purity monitor: LCD readout in µS/cm with flashing red LED alarm Ion exchange capacity: ~1,500 grains as CaCO3
System warranty: One (1) year
DI WATER SYSTEMS**
DESCRIPTION PART NO. PRICE
Model H-01-C Type 2 DI System, 110V 656230 Model H-01-C Type 2 DI System, 220V 656231 Model H40-RO+ DI System, 110V 656232 Model H40-RO+ DI System, 220V 656233
Purification Kit for H-01-C 656234
Purification Kit for H40-RO 656235
Model H-01-C DI System
12"W x 18"H x 12"D Model H40-RO+ DI System 20"W x 20"H x 12"D
Hydrogen Generators
How do You Determine What Model You Need?
Table 2 shows a break down of the hydrogen gas generators by models and flow. Column (1) shows the use of hydrogen used only as a fuel gas for FID detectors. Column (2) shows the use of hydrogen to supply a detector, as a carrier gas for a GC capillary column and allows for one FID detector, septum purge, split venting, and the column flow.
Between columns 1 and 2 are listed the models for the manufacturers we handle.
Going across the table you will find one or more models of hydrogen generator that will meet your flow needs. If your flow need exceeds the flows shown in this table you will need to use more than one hydrogen generator.
After determining what models meet your flow needs, then go to the specifications table to determine the best model based on the features you desire. Then go to page 453 for part numbers and price comparisons.
* Total dissolved solids
Deionized Water Systems for Hydrogen Generators
Contact your Alltech offi ce or distributor for current or local prices.
© Copyright 2004 Alltech Associates, Inc. © Copyright 2004 Alltech Associates, Inc. Contact your Alltech offi ce or distributor for current or local prices.
452
452 453 453
6253 6096
6515
6626 6627
Gas Generators – Hydrogen
PARKER CHROMGAS™ DESCRIPTION
FLOW
(CC/MIN.) 110V
PART NO. 220V
PART NO. PRICE
Model 9090 90 97002 97003
Model 9150 160 90614 97004
Model 9200 250 90741 97007
Model 9400 500 90761 97008
H2-800 800 97183 97193
Model 9800 1200 90780 97009
PARKER BALSTON*
DESCRIPTION
FLOW
(CC/MIN.) 110V
PART NO. 220V
PART NO. PRICE
Model H2-150 150 80109 80113
Model H2-300 300 80112 80115
*Must specify country of destination when ordering.
FID1000 AND FID2500 ACCESSORIES
DESCRIPTION PART NO. PRICE
Desiccant Cartridge 90723
Deionizer Resin Bags 1647728
In-Line Filter (Zero Air) 1647729
Maintenance Kit 1647731
Inlet/Outlet Filters Zero Air 1647732
PARKER CHROMGAS™ ACCESSORIES
DESCRIPTION PART NO. PRICE
Desiccant Cartridge** 90723
Deionizer Bags, 2/pk 9076
**For Models 9090, 9150, 9200, and 9400. Model H2-800 and 9800 do not require a desiccant cartridge.
Parker Balston Hydrogen Generator Parker ChromGas
Hydrogen Generator FID1000 Gas
Station
MATHESON CHRYSALIS II*
DESCRIPTION FLOW
(CC/MIN.) 110V
PART NO. 220V
PART NO. PRICE
SEPG100 100 37240 37273
SEPG160 160 37241 27279
SEPG250 250 37242 27285
SEPG500 500 37243 27291
SEPG100 w/RC 100 37244 27297
SEPG160 w/RC 160 37246 27304
SEPG250 w/RC 250 37247 27399
SEPG500 w/RC 500 37248 27317
SEPG250 w/CF 250 37252 27323
SEPG500 w/CF 500 37253 27329
HPNM100 100 37257 27336
HPNM160 160 37258 27342
HPNM250 250 37259 27349
HPNM500 500 37260 27355
HPNM100 w/RC 100 37261 27361
HPNM160 w/RC 160 37262 27367
HPNM250 w/RC 250 37263 27373
HPNM500 w/RC 500 37264 27379
HPNM250 w/CF 250 37265 27385
HPNM500 w/CF 500 37266 27391
Hydrogen Generators
*Must specify country of destination when ordering.
SEPG-Chrysalis® II Hydrogen Generator HPNM-Chrysalis® II
Hydrogen Generator
SEPG = Standard Economy Purifi ed Gas Series HPNM = High Performance No Maintenance Series RC = Remote Control
CF = Cascading Flow
MATHESON CHRYSALIS II ACCESSORIES AND OPTIONS
DESCRIPTION PART NO. PRICE
Interface/Control Cable System 37267 External Remote Control Handheld Module 37268 Deionizer Bag (Replacement) 2/pk 37269 Auxiliary Source Kit (HYC-BGS-Kit) 37081 Remote Control Cable (15-Conductors)-25ft 37270 Remote Control Cable (15-Conductors)-50ft 37271 Remote Control Cable (15-Conductors)-100ft 37272
For more information on hydrogen generators request Gas Management Supplies Brochure #457, for Parker Balston Hydrogen Generators request datasheet 80109D, for Parker ChromGas™ request datasheet 90741D, and for Matheson Chrysalis II request datasheets 37240D and 37257D.
FID1000 AND FID2500 GAS STATIONS*
DESCRIPTION FLOW
(CC/MIN.) 110V
PART NO. 220V
PART NO. PRICE FID1000 Gas Station 90/1000 97128 97185
FID2500 Gas Station 250/2500 97211 97212
*Both the FID1000 and FID2500 Gas Stations provide zero air and hydrogen