• 검색 결과가 없습니다.

Statistical analysis

문서에서 저작자표시 (페이지 131-152)

Chapter 4. Synthesis of quercetin derivatives

4.5. Statistical analysis

실험 결과는 3번 반복실험 후 (SPSS version 22)를 이용하여 통계처리 하였으며, 실 험에 의해 얻어진 값들의 평균을±표준편차로 나타내었다. 대조군과 실험군 사이의 통계학적 유의성 검증은 t-Test 사용하였으며, p<0.05 수준에서 검정하였다.

114

Table 8. Information of reactants (quercetin, 4-Nitrobenzyl bromide, Na2CO3, and DMSO)

Quercetin syn EXP ①

Molecular Weight (g/mol)

Equivalent (eq)

Using weight

Quercetin 302.24 1 0.5 g

4-Nitrobenzyl bromide 216.03 1.2 0.42885 g

Na2CO3 105.99 1.2 0.2104 g

DMSO 15 ml

Table 9. Information of loading solvents and test tube numbers

Loading solvent Test tube no.

Hexane:EtOAc (7:3) 1~13

Hexane:EtOAc (5:5) 14~23

115

Fig. 44. TLC bands of open column fractionations of nucleophile 4-Nitrobenzyl bromide reacted with quercetin. Note that ‘Q’ is marked quercetin.

Table 10. Information of loading solvents and test tube numbers

Label Test tube no.

Quercetin syn EXP ①-1 3

Quercetin syn EXP ①-2 4

Quercetin syn EXP ①-3 5~7

Quercetin syn EXP ①-4 8~10

Quercetin syn EXP ①-5 11~14

116

Table 11. Information of reactants (quercetin, Benzyl bromide, Na2CO3, and DMSO)

Quercetin syn EXP ② Molecular Weight (g/mol)

Equivalent (eq)

Using weight

Quercetin 302.24 1 0.5 g

Benzyl bromide 171.03 1.2 236 μl

Na2CO3 105.99 1.2 0.2104 g

DMSO 15 ml

117

Fig. 45. TLC bands of synthesized quercetin derivatives after reaction for 4.5, 5.5, 11, and 6.6 hr.

Table 12. Information of loading solvents and test tube numbers

Loading solvent Test tube no.

Hexane:EtOAc (8:2) 1~9

Hexane:EtOAc (7:3) 10~13

Hexane:EtOAc (5:5) 14~15

Hexane:EtOAc (3:7) 16~17

Hexane:EtOAc (0:10) 18~21

After 4.5 hr After 5.5 hr After 6.6 hr

118

Fig. 46. TLC bands of open column fractionations of nucleophile benzyl bromide reacted with quercetin. Note that ‘Q’ is marked quercetin.

Table 13. Information of samples and test tube numbers

Label Test tube no.

Quercetin syn EXP ②-1 1

Quercetin syn EXP ②-2 2~4

Quercetin syn EXP ②-3 5~10

Quercetin syn EXP ②-4 11

Quercetin syn EXP ②-5 12

Quercetin syn EXP ②-6 13~21

119

Table 14. Information of reactants (quercetin, 4-Bromophenethyl bromide, Na2CO3, and DMSO)

Quercetin syn EXP ③

Molecular Weight (g/mol)

Equivalent (eq)

Using weight

Quercetin 302.24 1 0.5 g

4-Bromophenethyl bromide 263.96 1.2 303 μl

Na2CO3 105.99 1.2 0.2104 g

DMSO 15 ml

.

120

Fig. 47. TLC bands of synthesized quercetin derivatives after reaction for 3.5, 4.5, 11, and 20.5 hr.

Table 15. Information of loading solvents and test tube numbers

Loading solvent Test tube no.

Hexane:EtOAc (7:3) 1~2

Hexane:EtOAc (5:5) 3~7

Hexane:EtOAc (3:7) 8~9

Hexane:EtOAc (0:10) 10~15

After 3 hr 30 min

After 4 hr 30 min

After 11 hr

After 20 hr 30 min

Q

121

Fig. 48. TLC bands of open column fractionations of nucleophile 4-Bromophenethyl bromide reacted with quercetin. Note that ‘Q’ is marked quercetin.

Table 16. Information of samples and test tube numbers

Labeling Test tube no.

Quercetin syn EXP ③-1 1

Quercetin syn EXP ③-2 2,3

Quercetin syn EXP③-3 4,5

Quercetin syn EXP ③-4 6,7

Quercetin syn EXP ③-5 8~12

122

Table 17. Information of reactants (quercetin, 4-Methylphenethyl bromide, Na2CO3, and DMSO)

Quercetin syn EXP ④

Molecular Weight (g/mol)

Equivalent (eq)

Using weight

Quercetin 302.24 1 0.5 g

4-Methylphenethyl bromide 199.09 1.5 3,783 μl

Na2CO3 105.99 1.5 0.2630 g

DMSO 11 ml

123

Fig. 49. TLC bands of synthesized quercetin derivatives after reaction for 5, 6, 22, and 28 hr.

Table 18. Information of loading solvents and test tube numbers

Loading solvent Test tube no.

Hexane:EtOAc 8:2 1

Hexane:EtOAc 7:3 2~7

Hexane:EtOAc 5:5 8,9

Hexane:EtOAc 3:7 10,11

EtOAc 10 12~15

After 5 hr

After 6 hr

After 22 hr

After 28 hr

124

Fig. 50. TLC bands of open column fractionations of nucleophile 4-Methylphenethyl bromide reacted with quercetin. Note that ‘Q’ is marked quercetin.

Table 19. Information of samples and test tube numbers

Label Test tube no.

Quercetin syn EXP ④-1 1

Quercetin syn EXP ④-2 2

Quercetin syn EXP ④-3 3

Quercetin syn EXP ④-4 4

Quercetin syn EXP ④-5 5~6

Quercetin syn EXP ④-6 7

125

Table 20. Information of reactants (quercetin, (s)-(+)-Citronellyl bromide, Na2CO3, and DMSO)

Quercetin syn EXP ⑤

Molecular Weight (g/mol)

Equivalent (eq)

Using weight

Quercetin 302.24 1 0.5 g

(s)-(+)-Citronellyl bromide 219.16 1.5 4,899 μl

Na2CO3 105.99 1.5 0.2630 g

DMSO 11 ml

126

Fig. 51. TLC bands of synthesized quercetin derivatives after reaction for 4, 15, 21, and 24 hr.

Table 21. Information of loading solvents and test tube numbers

Loading solvent Test tube no.

Hexane:EtOAc 8:2 1~4

Hexane:EtOAc 7:3 5~6

Hexane:EtOAc 5:5 7

Hexane:EtOAc 3:7 8~10

EtOAc 10 11~12

After 4 hr

After 15 hr

After 21 hr

After 24 hr

127

Fig. 52. TLC bands of open column fractionations of nucleophile (s)-(+)-Citronellyl bromide reacted with quercetin. Note that ‘Q’ is marked quercetin.

Table 22. Information of samples and test tube numbers

Label Test tube no.

Quercetin syn EXP ⑤-1 1,2

Quercetin syn EXP ⑤-2 4

Quercetin syn EXP ⑤-3 4

Quercetin syn EXP ⑤-4 5~7

Quercetin syn EXP ⑤-5 8

Quercetin syn EXP ⑤-6 9

128

Table 23. Information of reactants (quercetin, 1-Bromo-2-methylpropane, Na2CO3, and DMSO)

Quercetin syn EXP ⑥

Molecular Weight (g/mol)

Equivalent (eq)

Using weight

Quercetin 302.24 1 0.5 g

1-Bromo-2-methylpropane 137.02 1.5 2,699 μl

Na2CO3 105.99 1.5 0.2630 g

DMSO 12 ml

129

Fig. 53. TLC bands of synthesized quercetin derivatives after reaction for 4, 15, and 21 hr.

Table 24. Information of loading solvents and test tube numbers

Loading solvent Test tube no.

Hexane:EtOAc (7:3) 1~2

Hexane:EtOAc (5:5) 3~6

Hexane:EtOAc (3:7) 7~8

EtOAc (0:10) 9~10

After 4 hr

After 15 hr

After 21 hr

130

Fig. 54. TLC bands of open column fractionations of nucleophile 1-Bromo-2-methylpropane reacted with quercetin. Note that ‘Q’ is marked quercetin.

Table 25. Information of samples and test tube numbers

Label Test tube no.

Quercetin syn EXP ⑥-1 1

Quercetin syn EXP ⑥-2 2

Quercetin syn EXP ⑥-3 3,4

Quercetin syn EXP ⑥-4 5

Quercetin syn EXP ⑥-5 6

Quercetin syn EXP ⑥-6 7,8,9

131

Table 26. Information of reactants (quercetin, oleyl bromide, Na2CO3, and DMSO)

Quercetin syn EXP ⑦

Molecular Weight (g/mol)

Equivalent (eq)

Using weight

Quercetin 302.24 1 0.5 g

Oleyl bromide 331.37 1.5 8,256 μl

Na2CO3 105.99 1.5 0.2630 g

DMSO 12 ml

132

Fig. 55. TLC bands of synthesized quercetin derivatives after reaction for 23 and 30 hr.

Table 27. Information of loading solvents and test tube numbers

Loading solvent Test tube no.

Hexane:EtOAc (8:2) 1~5

Hexane:EtOAc (7:3) 6~9

Hexane:EtOAc (5:5) 10~11

Hexane:EtOAc (3:7) 12~15

After 23 hr

After 30 hr

133

Fig. 56. TLC bands of open column fractionations of nucleophile oleyl bromide reacted with quercetin. Note that ‘Q’ is marked quercetin.

Table 28. Information of samples and test tube numbers

Label Test tube no.

Quercetin syn EXP ⑦-1 1

Quercetin syn EXP ⑦-2 2

Quercetin syn EXP ⑦-3 3

Quercetin syn EXP ⑦-4 4,5

Quercetin syn EXP ⑦-5 6~10

Quercetin syn EXP ⑦-6 11,12

Quercetin syn EXP ⑦-7 13,14

134

문서에서 저작자표시 (페이지 131-152)

관련 문서