環境 및 生態工學
大 韓 土 木 學 會 論 文 集第30卷 第2B 號·2010年 3月 pp. 219 ~ 231
Reference Evapotranspiration Calculator Software를 이용한 기상관측소 기준증발산 추정
Estimation on Trends of Reference Evapotranspiration of Weather Station Using Reference Evapotranspiration Calculator Software
최원호*·최민하**·오현제***·박주양****
Choi, Wonho·Choi, Minha·Oh, Hyunje·Park, Jooyang
···
Abstract
The Reference Evapotranspiration Calculator Software (REF-ET) supports computational guidelines for the reference evapo- transpiration using seventeen FAO Penman-Monteith (PM) equations simultaneously such as the ASCE and FAO standardized forms. The REF-ET can conveniently consider missing data predictions and regional site characterizations, when reference ET is computed on monthly, daily, and hourly time steps. The applicability of the REF-ET was estimated to simulate the reference ET using hourly weather data from Seoul weather station for 29 years. The result found that the FAO24-Rd and 1957-Makk equations closely concerned with solar radiation parameter which were the most highly correlated to reference ET computed by pan coefficient. In addition, the 1957-Makk equation was identified as the most correct computational method for reference ET by analysis of bias and root mean square error. The 1957-Makk equation could predict the reference ET within the error of less than 1.06 mm/day, though all the other equations tended toward overestimation of predicting the reference ET in comparison with refecence ET of pan. The results of this study suggest that the REF-ET will be applicable to support reference ET esti- mation for a variety of field condition and time-scale.
Keywords : REF-ET, FAO Penman-Monteith equations, evapotranspiration, reference evapotranspiration
···
요 지
Reference Evapotranspiration Calculator Software (REF-ET) 는 ASCE 및 FAO 기준증발산량을 포함한 총 17 개의 FAO
Penman-Monteith (PM) 방정식의 연산을 동시에 수행할 수 있는 프로그램으로서 , 본 연구에서는 REF-ET 에 대한 상세한
소개와 함께 기상관측소의 관측자료를 이용하여 REF-ET 의 효용성을 논하였다 . REF-ET 는 각종 PM 방정식들에 대한 시일
월 단위 모의와 지역적 특성의 반영 및 결측자료에 대한 보정 등이 가능하다 . REF-ET 를 이용하여 서울 기상관측소의 29
년간 증발산량을 모의한 결과 , 일복사량에 주로 좌우되는 FAO24-Rd 식과 1957-Makk 식의 상관계수가 각각 0.89 와 0.88
로 높게 나타났으며 , 이는 소형증발접시를 이용한 기준증발산량 관측값이 공기 동력학적 증발량만을 주로 반영하기 때문인
것으로 사료된다 . 또한 RMSE/bias 분석을 통해 기준증발산 방정식들에 의한 계산값이 증발접시로부터의 기준증발산량에 비
해 다소 과대평가되는 현상을 나타내었으나 , 이 경우에도 1957-Makk 식이 가장 정확한 것으로 나타났다 . 일단위 시계열 분
석시 1957-Makk 식은 여름철의 증발산량을 저평가하는 경향을 나타내었으나 , 전체적으로 1.06 mm/day 의 오차로 증발산량
을 모의 가능하였다 . 차후 기상관측자료의 정확도를 높이는 연구들과 REF-ET 를 병행한다면 , 해당 지역 및 기간에 대한 증 발산량 모의 및 관련 특성인자를 파악하는 연구에 활용도가 높을 것으로 기대된다 .
핵심용어 : REF-ET, FAO PM 방정식 , 증발산 , 기준증발산
···
1. 서 론
증발산 (evapotranspiration) 은 자연계의 물 순환 과정에 있
어 약 70% 정도를 차지하는 중요한 구성요소로서 , 정확한
증발산량의 추정은 생태계의 물 순환 및 물 수지를 이해하
는데 필수적일 뿐만 아니라 각종 수자원 활용 정책 관리의 주요한 의사지원 수단으로 활용될 수 있다 ( 홍진규와 김준 , 1996; 윤진일 등 , 2004). 특히 최근 도시영역의 확대와 더불 어 기존 자연 물 순환계의 왜곡이 심화됨에 따라 지역생태 계 뿐만 아니라 인간사회에도 물 순환 불균형에 따른 부작
*정회원·한양대학교공과대학건설환경공학과박사과정
(E-mail : [email protected])
**정회원·한양대학교공과대학건설환경공학과조교수
(E-mail : [email protected])
***정회원·한국건설기술연구원건설환경연구실책임연구원·상하수도기술사
(E-mail: [email protected])
****정회원·교신저자·한양대학교공과대학건설환경공학과부교수
(E-mail : [email protected])
용이 심각한 사회문제로 대두되는 실정이며 , 이러한 왜곡된 물 순환을 다시 건전화 (rehabilitation) 하기 위한 기초연구 중 의 하나로서 정확한 증발산량 추정의 중요성이 재고되고 있 다 ( 김해동 등 , 2006; 임창수 , 2008).
증발산량을 파악하기 위한 방법은 측정장비를 이용한 직접 적인 관측과 증발산 모형을 이용한 간접적인 산정 방법이 있으며 , 전자의 경우 최근 활발히 시도되고 있는 에디공분산 플럭스 관측이 대표적인 예이나 이는 관측지에 대한 지형적 제한사항이 상존하고 에너지 수지 관측 및 해석의 어려움이 있어 ( 윤진일 등 , 2004; 강민석 등 2008) 아직까지는 연구단 계의 수준이다 . 따라서 현재까지 일반적으로 널리 쓰이고 있 는 증발산 추정 방법은 후자인 모형을 이용한 간적접인 산
정법이며 , 그 중에서도 Penman(1948) 에 의해 제시되고
Monteith(1965) 에 의해 일반화된 Penman-Monteith( 이하
PM) 복합방정식 (combination equation) 이 대표적이다 . 최초 의 PM 복합방정식은 열과 수증기에 의한 확산 저항의 고려 가 부족하였음에도 불구하고 일반적인 상황 하의 증발산을 비교적 정확히 모의할 수 있다 . 따라서 대다수 연구자들은 이를 기준증발산 (reference evapotranspiration) 산정의 새로
운 기준으로 수용하고 진단적 기능과 예측적 가능성을 개선 하는 연구를 진행하여 왔다 . 국제연합식량농업기구 (FAO;
Food and Agriculture Organization) 및 미국토목학회 (ASCE;
American Society of Civil Engineers) 등은 이러한 연구들 을 종합하여 기준증발산량 산정을 위한 표준방법을 제시하 였으며 , 세계의 연구자들은 이를 토대로 각 지역별 특성에 따른 여러 가지 기준증발산식의 변화와 적용성 등을 보고하 였다 (Allen et al ., 1998; Walter et al. , 2000).
기준증발산식과 관련되어 진행된 국내연구 사례들 역시 해 외연구와 마찬가지로 FAO PM 방정식 등을 이용하여 특정
지역의 증발산 추이를 모의하거나 모형의 정확도를 높이기 위해 방정식을 이루는 각 변수의 민감도 등을 분석하는 연 구들이 주로 이루어졌다 ( 정하우 외 , 1988; 황숙지 외 , 2000;
강민석 외 , 2008; 임창수 , 2008). 그러나 외국에 비해 상대 적으로 지형이 복잡하고 토지이용의 비균질성이 높은 우리 나라의 경우 국외의 연구사례를 그대로 적용하기 어려운 면 이 많을 뿐만 아니라 , 기준증발산식에서 기준작물로서 가정 하는 잔디 (grass) 와 알팔파 (alfalfa) 의 적용기준이 명확하지 않 다 . 따라서 국내 실정에 알맞는 기준증발산량 산정방법을 선 정하기 위해서는 기존 여러 가지 기준증발산식들에 대한 충 분한 검토와 분석이 이루어져야 하나 , 각 식을 구성하는 변 수에 적합한 입력자료의 구축과 모의는 매우 방대한 시간과 노력을 요하므로 현실적으로 어려운 부분이 많다 .
본 연구에서는 이러한 어려움을 해결하기 위한 방법으로서
REF-ET(Reference Evapotranspiration Calculator Software)
프로그램을 이용한 기준증발산량 모의 방법을 제시하고자 한
다 . REF-ET 는 각종 기준증발산량 계산을 위해 미국 Idaho
대학의 Kimberly R&E 센터에서 개발한 프로그램이다
(Allen, 2000). REF-ET 는 ASCE 와 FAO 에서 제시한 표준
기준증발산량 산정법을 포함하여 총 17 개의 방정식을 잔디 및 알팔파 기준작물에 대해 한 번의 실행으로 모의 가능하 므로 각종 기준증발산량 산정식을 일일이 모의하는 수고를 획기적으로 줄일 수 있을 뿐만 아니라 해당 지역에 가장 정 확도가 높은 PM 방정식을 선정하는 데에 용이하다 . 본 연 구에서는 서울 기상관측소의 1980 년도부터 2008 년까지 약
30 년에 걸친 관측자료를 이용하여 REF-ET 모의를 수행하고 각 기준증발산식의 추이를 분석하며 , 최종적으로 서울 지역
의 기준증발산량 산정에 가장 정확도가 높은 기준증발산식 을 제시함으로써 REF-ET 의 효용성을 입증함을 목표로 한다 . Table 1. Reference evapotranspiration equations supported by REF-ET
The standardized ASCE-PM equation
ET
ostandardized grass-reference ET (mm d
−1or mm h
−1)
∆ slope of saturation vapor pressure versus air temperature curve (kPa °C
−1)
R
ncalculated net radiation at the crop surface (MJ m
−2d
−1for 24 h timesteps, or MJ m
−2h
−1for hourly timesteps)
G heat flux density at the soil surface (MJ m
−2d
−1for 24 h timesteps, or MJ m
−2h
−1for hourly timesteps) T mean daily or hourly air temperature at 1.5 to 2.5 m height (°C)
u
2mean daily or hourly wind speed at 2 m height (m s
−1) e
s- e
avapor pressure deficit (kPa) psychrometric constant (kPa °C
−1) e
ssaturation vapor pressure (kPa)
e
aactual vapor pressure (kPa)
C
nnumerator constant that changes with reference surface and calculation timesteps (900°C mm s
3Mg
−1d
−1for 24 h timesteps, and 37°C mm s
3Mg
−1h
−1for hourly timesteps for the grass-reference surface)
FAO-56 Penman-Monteith Equation
ET
ograss reference evapotranspiration, mm d
−1R
nthe net radiation at the crop surface, MJ m
−2d
−1G the soil heat flux density, MJ m
−2d
−1T mean daily air temperature at 2 m height,
oC e
s- e
asaturation vapor pressure deficit, kPa e
ssaturation vapor pressure of the air, kPa e
aactual vapor pressure of the air, kPa
∆ slope vapor pressure curve, kPa
−1 oC
−1γ the psychrometric constant, kPa
−1 oC
−1ET
o0.408 R (
n– G ) γ C
nT 273 + ---u
2( e
s– e
a) +
∆
∆ γ 1 C + ( +
du
2)
---
=
ET
o0.408 R ∆ (
n– G ) γ 900 + T 273 ---u +
2( e
s– e
a)
∆ γ 1 0.34u + ( +
2) ---
=
2. 모형과 입력자료 2.1 REF-ET 개요
REF-ET 는 ASCE Reports on Engineering Practice No.70
에서 Jensen 등 (1990) 이 제시한 기준증발산량 산정 계산방법 과 표준화 된 ASCE Penman-Monteith 식 (2000) 및 FAO Irrigation Paper No.56 에서 Allen 등 (1998) 의 연구를 기초 로 한 FAO-56 Penman-Monteith 식 등을 기본적으로 제공
하며 , 그 외에도 Preistley-Taylor(1972) 방법 , 초기 형태의
Penman 식 (1948, 1963) 등을 포함하고 있다 (Table 1).
REF-ET 에 포함되어 있는 대부분의 기준증발산량 산정식
은 월 (monthly) 단위 및 일 (daily) 단위 모의를 수행할 수
있으며 , 그 중 Kimberly Penman, CIMIS Penman, 1963 Penman 식들은 시 (hourly) 단위 계산이 가능하다 . 모의시 기준작물은 기본적으로 잔디를 기준으로 계산되며 (ET
o), 알 팔파 기준작물에 대한 기준증발산량 (ET
r) 은 각 계산식 연구
Table 1. Reference evapotranspiration equations supported by REF-ET
1948 or 1963 version
of Penman K
W= 6.43 for ET
o, mm d
−1= 0.268 for ET
r, mm hour
−1a
W, b
Wwind function coefficients u
2wind speed at 2 m, m s
−1λ latent heat of vaporization, MJ kg
−1FAO-24 Penman
c depends on shortwave radiation, maximum relative humidity, daytime wind speed and ratio of daytime to night-time wind
FAO-24 Pan
c pan coefficient
FAO-24 Radiation Method W depends on temperature and altitude
c depends on mean relative humidity and daytime wind speed.
FAO-24 Blaney-Criddle p daily percentage of total annual daytime hours and depends only on the latitude and time of year c depends on minimum relative humidity, sunshine hours, and daytime wind speed
1985 Hargreaves
Temperature Method ET
ograss reference ET, mm d
−1T
maxmaximum daily air temperature,
oC T
minminimum daily air temperature,
oC
T
meanmean daily air temperature, computed as (T
max+T
min)/2 R
aextraterrestrial radiation, mm d
−1(mm d
−1=MJ m
−2d
−1/2.45)
Priestley-Taylor Radiation
and Temperature Method ET
ograss reference ET, mm d
−1R
nthe net radiation, MJ m
−2d
−1G the soil heat flux density, MJ m
−2d
−1λ latent heat of vaporization, MJ kg
−1∆, γ as defined for the Penman equations, kPa
oC
−1Makkink Radiation
and Temperature Method ET
ograss reference ET, mm d
-1R
ssolar radiation, MJ m
-2d
-1∆ , γ as defined for the Penman equations, kPa
oC
−12.45 latent heat of vaporization at approximately 20
oC, constant
Turc Radiation and Temperature Method (only be applied if T
mean> -10
oC)
ET
ograss reference ET, mm d
−1R
ssolar radiation, MJ m
−2d
−1T
meanmean daily air temperature,
oC
λ latent heat of vaporization, MJ kg
−1a
T= 1.0 for RH
mean≥ 50%
= 1.0+(50-RH
mean)/70 for RH
mean<50% (where, RH mean : mean daily relative humidity, %)
ET
oor ET
r∆
∆ γ +
--- R (
n– G ) K
Wγ
∆ γ +
--- a (
W+ b
Wu
2) e (
s– e
a)
⎝ + ⎠
⎛ ⎞ λ ⁄
=
c 0.408 ∆ ∆ γ --- R + (
n– G ) 2.7 γ + ∆ γ --- 1 0.864U + ( + ) e (
s– e
a)
c pan reading [ ] c 0.408WR [
s]
c p [ ( 0.46 T + 8 ) ]
ET
o0.0023 T (
max– T
min)
2T
mean
+ 17.8
( )R
a=
ET
o1.26 ∆ γ --- ∆ + R
n– G --- λ
=
ET
o0.61 ∆ ∆ γ --- + R
s2.45 --- 0.12 –
=
ET
oa
T0.013 Tmean ---23.8856 Tmean + 15 R
s+ 50 --- λ
=
시 제시된 ET
r/ET
o비율을 참조로 산정되거나 또는 사용자 에 의해 직접 입력된 ET
r/ET
o비율을 기준으로 산정된다
(Allen, 2000). REF-ET 로 계산할 수 있는 기준증발산식의
종류와 각 계산식별 시간 단위 및 기준작물을 Table 2 에 나타내었다 .
2.2 REF-ET 입력자료 (서울 기상관측소 관측자료)
REF-ET 의 입력자료는 텍스트 형태의 ASCII 파일을 이용
한다 . 계산시 필요로 하는 기상 관측항목은 기온 , 복사량 ,
상대습도 등 약 30 여개이며 , 각 항목 별로 다양한 단위의 형태를 제공하므로 입력자료 구축시 실제 선택할 수 있는 옵션은 총 85 개에 달한다 . 각 항목은 ASCII 파일로 제작시 공백이나 탭 , 쉼표 등으로 미리 구분하여야 REF-ET 상에서 분류시켜 입력할 수 있으며 , 모의시 불필요한 자료는 더미
(dummy) 로 분류하여 계산 과정에서 제외하여야 한다 .
본 연구에서는 국내 기상관측소 중 서울 기상관측소를 선
택하여 REF-ET 에 적용하였다 . 기상관측자료는 기상청
(www.kma.go.kr) 과 WAMIS(www.wamis.go.kr) 에서 제공되 는 1980 년도부터 2008 년까지 서울 기상관측소 ( 종로구 송월 동 ) 의 일단위 순별 기상자료를 이용하였으며 , 이 중 다음
Table 3 에 해당하는 관측항목들을 REF-ET 에 입력하였다 .
REF-ET 는 보다 정확한 계산을 위하여 기상 관측자료 외
에 기상관측소의 지역적 특성에 관련된 변수들을 입력할 수 있도록 되어 있다 . 이 때에는 풍속계·온도계·상대습도계 등의 높이와 관측소의 경도·위도 및 해발높이 등을 고려하 며 , 본 연구에서는 서울 기상관측소의 제원을 참조하여 위도
37.3417°, 해발고 85.45 m 를 입력하였고 , 풍속계 (anemometer)
및 온도·습도계의 높이는 백엽상의 평균높이로서 각각 10 m
와 1.5 m 로 가정하였다 . 이 외에도 REF-ET 의 기준작물인
잔디 식생의 높이는 FAO-56 의 권고 표준안을 참조하여
0.12 m 로 가정하였다 .
2.3 결측자료의 보정
시계열 기상관측 자료를 구축함에 있어 결측이 전혀 없는 완벽한 기상관측은 실질적으로 매우 어려우므로 REF-ET 는 계산을 수행하기 전 단계에서 결측 기상자료에 대한 조정 옵션을 제공한다 . 결측에 대한 보정이 가능한 항목들은 일조 량과 일조시간 , 풍속 , 상대습도 , 증기압 및 이슬점 등이며 ,
기온 항목은 결측에 대한 보정이 불가하므로 최소한 최고기 온이나 최저기온에 대한 측정값은 반드시 제시되어야 한다
(Allen, 2000). 각 결측항목들은 결측시점 이전의 자료들로
외삽하여 계산을 수행하거나 FAO-56 규격에서 제시하는 권
고치 또는 사용자의 직접 입력 등에 의해 보정된다 . Table
4 에 각 결측항목에 대해 REF-ET 에서 제공되는 보정 방법을
Table 2. Reference evapotranspiration calculation methods provided by REF-ET (from “ REF-ET manual ” by Allen, 2000)
Methods Timesteps Ref. type
“full” ASCE Penman-Monteith with resistances by Allen et al ., 1989 (M, D, or H) ET
oET
r“full” ASCE Penman-Monteith with user supplied surf. resistance (M, D, or H) ET
oET
rStandardized form of the ASCE Penman-Monteith by ASCE 2000 (M, D, or H) ET
oET
r1982 Kimberly Penman (Wright, 1982; 1987; 1996) (M, D, or H) ET
oET
rFAO-56 Penman-Monteith (1998) with resistance for 0.12 m grass (M, D, or H) ET
o1972 Kimberly Penman (fixed wind func.) (Wright & Jensen 1972) (M, D, or H) ET
r1948 or 1963 Penman (Penman, 1948; 1963) (M, D, or H) ET
oFAO-24 Corrected Penman (Doorenbos and Pruitt, 1975, 1997) (M or D) ET
oFAO-PPP-17 Penman (Freres and Popov, 1997) (M or D) ET
oCIMIS Penman (hourly only) with FAO-56 R
nand G=0 (H) ET
oFAO-24 Radiation Method (Doorenbos and Pruitt, 1975, 1997) (M or D) ET
oFAO-24 Blaney-Criddle (Doorenbos and Pruitt, 1975, 1997) (M or D) ET
oFAO-24 Pan Evaporation Method (Doorenbos and Pruitt, 1975, 1997) (M or D) ET
o1985 Hargreaves Temperature Method (Hargreaves and Samani) (M or D) ET
oPriestley-Taylor (1972) Radiation and Temperature Method (M or D) ET
oMakkink (1957) Radiation and Temperature Method (M or D) ET
oTurc (1961) Radiation and Temperature Method (M or D) ET
oTable 3. Measurement data of Seoul weather station for identifying REF-ET input data
서울 기상관측소
관측항목 ( 단위 ) REF-ET Input data ID no.
연도 Year, 0000-2999 63
월 Month, 1-12 58
일 Day, 1-31 59
강수량 (mm/day) Precipitation, mm 56
최저기온 (
oC) Min Daily Air Temp. C 4
평균기온 (
oC) Mean Air Temp, C 7
최고기온 (
oC) Max Daily Air Temp, C 3
평균풍속 (m/s) Ave. Wind Speed, m/s 29
최소 상대습도 (%) Min. Daily Rel. Humidity, % 19
평균 상대습도 (%) Ave. Rel. Humidity, % 21
이슬점 (
oC) Dewpoint Temperature, C 17
일사량 (MJ/m
2) Solar Radiation, MJ/m2/d 10
일조시간 (hr) Sunshine Hours (daily) 66
나타내었다 .
1980 년 ~2008 년간의 서울 기상관측소 자료의 경우 1982 년
의 최소 상대습도와 47 일간의 이슬점 및 1421 일간의 일조시 간 관측자료가 부재하였으며 , 각 결측자료는 결측시점 이전 의 자료들로부터 모사하는 방식으로 보정하여 계산을 수행 하도록 설정하였다 .
2.4 REF-ET 모의 실행
2.1-2.3 과정을 통해 구축된 서울 기상관측소 입력자료를
바탕으로 모의를 수행하였으며 , 그 구체적인 과정은 다음과 같다 . ① 먼저 엑셀로 정리한 기상자료를 텍스트 형식의
ASCII 파일로 변환한 후 , ② 각 항목에 대한 REF-ET 변 수를 지정하였으며 , ③ 2.2 에서 제시한 기상관측소 관련 특 성 변수들을 입력하고 ④ 마지막으로 계산을 수행할 기준증 발산식들을 선택한 후 REF-ET 를 실행하였다 . 이 때 단위는
SI 단위를 사용하였고 잔디와 알팔파의 높이 기본값은 각각
0.12 m 와 0.5 m 로 가정하였으며 , 식생밀도가 큰 국내 환경을 감안하여 ET
r/ET
o비율을 FAO-56 권고치의 최대값인 1.25
로 가정하였다 . 본 연구의 목적 중 하나인 서울 기상관측소 의 관측자료와 가장 부합하는 기준증발산식을 선정하기 위
하여 시자료를 필요로 하는 CIMIS Penman 및 FAO-24
Pan evapotranspiration 식을 제외한 16 개 기준증발산식들의 계산을 수행하였다 . 계산 후 모의값은 입력자료와 마찬가지
로 ASCII 파일로 저장되며 , 이를 워크시트로 변환하여 종
합·분석하였다 . 3. 결과 및 고찰
3.1 상관도 분석
REF-ET 를 이용하여 1980 년 ~2008 년 기간 동안 서울 기상 관측소 기준증발산량을 모의한 결과를 Fig. 1 에 나타내었으 며 , 별도로 R
2값을 Table 5 에 정리하였다 . 각 기준증발산식 의 ET
r및 ET
o계산값 (Y 축 ) 은 소형증발접시로부터의 기준증
발산값 (X 축 ) 과 함께 표현하였으며 , 이 때 X 축의 기준증발산 값은 서울 기상관측소의 소형증발접시 가능증발량 관측치를 고려하여 증발접시계수 (pan coefficient) 를 0.72 로 가정 , 기준 증발산량으로 변환 후 적용하였다 (Allen et al ., 1998; 윤용
남 , 2008). 이렇게 증발접시를 이용하여 증발산량을 산정하
는 방식은 그 정확성을 신뢰하기 어려운 경우가 많기 때문 에 (Sumner and Jacobs, 2005), 최근에는 침루계 (lysimeter)
나 현열플럭스 측정기 등을 이용하여 실제증발산량을 정확 하게 측정하려는 시도가 이루어지고 있다 . 그러나 서울의 경 우 실질적으로 증발산량 산정에 이용할 수 있는 자료는 증 발접시 측정값 뿐이므로 , 어느정도의 부정확성을 감안하더라 도 본 연구에서는 이를 이용하기로 하였다 .
관측값 대비 REF-ET 에서 계산된 각 모의값의 기울기 , y
절편 및 R
2값 등을 살펴보았을 때 , 계산된 기준증발산값 대부분이 관측값의 추이변화와 비슷한 양상을 나타내는 것 을 알 수 있다 . 특히 1957-Makk(Makkink radiation and temperature method) 식을 제외한 나머지 식들의 경우 ET
o값이 관측치와 매우 유사하며 ET
r값은 상대적으로 과대평가 된 것으로 나타났는데 , 이는 도시지역 내 위치한 서울 기상 관측소의 토지피복환경을 간접적으로 반영한다 할 수 있다 . R
2값이 가장 높게 나타난 기준증발산식은 FAO24-Rd(FAO- 24 radiation method) 로서 (R
2=0.79), 이 식은 단지 일평균기
온과 단파복사의 영향만을 고려하고 상대습도 및 일평균풍 속에 의해 결정되는 증발접시계수에 크게 좌우된다 (Chiew
et al. , 1995). 본 연구에서 가정한 증발접시계수는 실험을
통해 구한 값이 아니므로 FAO-24 식의 정확성에 대한 논의
는 엄밀히 단정 지을 수 없으나 , 지역 및 기후 특성을 충분 히 반영한 증발접시계수를 도출할 경우 일평균기온과 복사량 관측 데이터만으로도 실제 기준증발산량과 거의 유사한 모의 를 수행할 수 있다는 점을 알 수 있다 . 또한 1957-Makk 식
은 지열 (soil heat flux) 의 비중을 줄이고 순복사량에 따른 잠 열 (latent heat) flux 를 상대적으로 크게 고려한 Priestley- Taylor 방정식의 단순화 형태로서 (Jacobs et al ., 2004), 기준 증발산량 산정시 포화수증기압 곡선의 기울기 ( ∆ : slope of the saturation vapor pressure temperature relationship) 와 습도계 상수 (psychrometric constant) 및 일복사량 (solar radiation) 을 사용하여 관측치와 매우 유사한 모의 결과를 나타내었다
(R
2=0.78). 상대적으로 높은 R
2값을 나타낸 위 두식으로부터
판단할 때 , 소형증발접시 관측값은 증발량만을 표현하고 증 산 개념이 배제되어 있으므로 실제 기준증발산량을 정확히 반영하기에는 무리가 있음을 알 수 있다 . 이는 최근 실제 증발산량이 증가함에도 불구하고 증발접시에서 관측되는 증
발산량은 오히려 감소되는 역설 (paradox) 적 관계에 대한 연
Table 4. Estimation methods for adjusting missing climatic data in REF-ET (from “ REF-ET manual ” by Allen, 2000)
Missing data Estimating methods remarks reference
Humidity T
dew: dewpoint temperature
T
min: min. air temperature
K
o: 2(dry), 0(subhumid) Allen (1996)
Solar Radiation k
Rs: adjustment coefficient
R
a: extraterrestrial radiation
T
max: max. air temperature Hargreaves and Samani (1985) Monthly wind
speed
light wind
light to moderate wind moderate to strong wind strong wind
≤ 1.0 m/s 1-3 m/s 3-5 m/s
≥ 5.0 m/s
no wind data: assuming 2 m/s (the average over 2,000 weather stations
around the globe) FAO-56 PM
Max. or Min. air
temperature T
maxand T
minequal to T
meanin no data
for T
maxand T
min. FAO-56 PM
T
dew= T
min– K
oR
s= k
Rs( T
max– T
min)R
aT
max– T
min( ) 1
k
Rs