http://dx.doi.org/10.15250/joie.2016.15.4.312 ISSN 2288-923X (Online)

어린이 생활환경 공간의 ELF-MF 노출량에 관한 연구

정준식1,2,†·이재원1·권명희1·김부욱3·김윤신2·홍승철4*

1국립환경과학원 생활환경연구과, 2한양대학교 보건학과,

3근로복지공단 직업성폐질환연구소, 4인제대학교 보건안전공학과

Study of ELF-MF levels in infant living environmental space at daycare centers

Joon-sig Jung1,2,†·Jae-Won Lee1·Myung-Hee Kwon1·Boo-Wook Kim3 Yoon-Shin Kim2·Seung-Cheol Hong4*

1Indoor air and noise Research division, National Institute of Environmental Research

2Department of Public Health, Hanyang University

3Occupational Lung Diseases Institute, Korea Workers’ Compensation and Welfare Service

4Department of Occupational Health & Safety Engineering, Inje University (Received 21 September, 2016; Revised 12 October, 2016; Accepted 18 October, 2016)

Abstract

The objective of this study was to investigate ELF-MF exposure levels in infant living environmental spaces at daycare centers. To achieve the objective of the study, we surveyed ELF-MF levels using EMDEX II at daycare centers from October 2013 to October 2014. The ELF-MF level of 53 daycare centers in terms of arithmetic mean (AM) and geometric mean (GM) were 0.59± 0.76 mG and 0.33 mG, respectively. And the ELF-MF level of 260 daycare center classrooms was 0.50± 0.71 mG (GM: 0.28 mG). The exposure levels of ELF-MF for all daycare centers were far below the recommended standards cited in guidelines in Korea (833 mG) and international reference levels proposed by WHO or ICNIRP (2,000 mG). Furthermore, we discovered out that as distance increased, ELF-MF emission levels decreased significantly in all electrical instruments. Below the 2 mG ELF-MF levels when an electrical instrument moved away stage 1 (Grade). Thus, these results will provide useful data for the determination of ELF-MF management and reduction methods at infant daycare centers.

Keywords : Electrical instrument, Daycare centers, ELF-MF, Living environmental space

1. 서 론

현대사회는 지속적인 문명의 발전과 함께 전기 및 전자기기의 사용량이 급격히 증가하고, 전기를 사용하 는 공간도 비약적으로 넓어지고 있는 실정이다. 이에 따라 극저주파 자기장(ELF-MF) 및 라디오파(RF-EMF)

의 노출량이 지속적으로 증가하고 있고 이로 인한 건 강영향(adverse health effects)의 논란이 발생하고 있다.

2002년 국제암연구소(IARC; International Agency for Research on Cancer)는 주거지의 어린이 백혈병 (leukemia)과 관련한 역학연구를 바탕으로 극저주파 자 기장을 발암가능성 의심물질인 “2b (possibly carcino- genic to humans; Group 2b)”로 분류 하였으며, 2011년 휴대폰 통화량과 뇌종양(glioma) 및 청신경종(aoustic neuroma)의 역학적 연구결과에 따라 라디오파를 2b로 추가 지정하였다(IARC, 2002; 2011).

ELF-MF 노출에 대한 직접적인 관심은 Wire-code를

*Corresponding author

Tel : +82-55-320-3677 E-mail : [email protected]

현재 소속기관은 ‘국립환경과학원 환경기반연구부 생활환경

연구과’ 임

(2)

어린이 생활환경 공간의 ELF-MF 노출량에 관한 연구 313

실내환경 및 냄새 학회지 제15권 제4호 (2016년 12월) 이용한 고압 송전선로 인근에 거주하는 소아 백혈병

연구 이후(Wertheimer and Leeper, 1979), 전 세계적으 로 많은 연구자들이 인체 위해성(adverse health effect) 과의 연관성에 대한 연구를 수행하였다(Savitz et al., 1988; London et al., 1991; Linet et al., 1997). Werthe- imer and Leeper. (1979)의 연구에서는 고압선로로부터 40 m 이내에 거주한 어린이들이 대조군 어린이들과 비 교하여 소아백혈병으로 사망할 위험성이 2-3배 높았으 며, 이러한 요인이 고압선로에서 발생하는 ELF-MF에 의한 것으로 추론하였다.

2007년에 세계보건기구(WHO: World Health Organ- ization)의 Environmental Health Criteria에서는 “사전 주의 원칙(Precautionary Principle)”에 의거하여 ELF- MF 노출 감소를 위한 자발적인 노력을 권고하고 있으 며(WHO, 2007), 또한 스웨덴, 네덜란드 같은 일부 국 가에서는 사회적 합의를 통하여 신설 환경민감시설(어 린이집, 학교 등)의 경우 고압송전선과의 적정 이격거 리를 설정하여 운영하고 있다. 고압송전선 인접 100 m 이내의 소아에 대한 역학 연구에서는 4 mG 이상의 ELF-MF에 노출되었을 때 급성 림프구성 백혈병(acute lymphoblastic leukemia) 발생 가능성이 4.73배 증가한 다고 하였다(Kabuto et al., 2006). 그러나 일반 생활환 경에서 ELF-MF 노출과 관련한 인체위해성 연구에서 는 현재까지 일관되고 명확한 결과를 나타내지 못하고 있는 실정이다.

어린이집에 상시적으로 거주하고 있는 유아(infant) 들은 성인(adult)보다 상대적으로 면역력이 약하고 환 경물질에 대하여 민감성이 높으므로 지속적으로 주변 유해 환경을 관리해야 한다. 그러나 현재까지 대부분의 ELF-MF 노출에 관한 연구는 일부 초등학교와 직업군 노출, 송전선로 주변에 대한 방출량 연구로 어린이집 실내 환경 노출에 대한 연구는 전무한 실정이다(Choi et al., 2015; Jung et al., 2015; 2016). 또한 어린이집 실내 ELF-MF 발생 전기 및 전자기기의 사용 실태조 사도 없으며, 이격거리에 따른 방출량 또한 조사 결과 가 미진한 실정이다.

따라서 본 연구는 우리나라 대도시에 소재한 일부 어 린이집의 실내 ELF-MF 노출량을 조사하는 것에 1차적 인 목적이 있으며, 추가적으로 내부 ELF-MF 발생기기 의 종류 및 이격거리에 따른 방출량을 파악하고자 한다.

2. 연구방법

2.1 연구대상

어린이집 실내 ELF-MF 노출량을 조사하기 위해

2013년 10월~2014년 10월까지 약 12개월간 대도시 지 역 일부 어린이집 53개소를 대상으로 조사하였다. 어 린이집 크기에 따라 5~11개 교실이 존재하므로 총 측 정 교실은 260개로 나타났다.

어린이집 주변에 고압송전선의 존재 여부를 선행적 으로 파악한 후, 고압송전이 존재하지 않으며, 측정 섭 외가 가능하며, 연구 참여 의사가 있는 어린이집을 대 상으로 모든 조건을 확인한 후에 조사를 실시하였다.

2.2 ELF-MF 측정 및 방법

연구 참여 어린이집을 대상으로 EMDEX II를 이용 하여 각 교실별 spot measurement을 실시하였으며, 동 시에 ELF-MF 발생기기를 조사하였다. EMDEX는 미 국 EPRI(Electric Power Research Institute)에서 개발한 Electric and Magnetic Field Digital Exposure System 으로 최대 분석 감도는 자기장의 경우 0.01 µT이고 최 대 분석 가능치는 300 µT, 측정치의 정확도는 ±3%이다.

외부 노출량의 영향을 배제하기 위하여 어린이들이 주로 활동하는 대상 교실 중앙 지점에서 조사를 실시 하였다. 또한 가전기기의 ELF-MF 방출량을 파악하기 위하여 이격거리별 방출량을 조사하였다. 이격거리는 총 4단계(stage 0: 밀착 측정, stage 1: 5 cm 이격 측정, stage 2: 15 cm 이격 측정, stage 3: 20 cm 이격 측정)로 구분하여 측정하였다.

2.3 통계분석 및 정도관리

측정자료의 통계학적 분석은 SPSS version 12.0 (SPSS Institute)을 사용하였다. 어린이집의 ELF-MF 노출량은 유아들의 환경보건학적 결과값의 활용을 위 하여 산술평균(mean) 및 표준편차(standard deviation;

SD), 최소-최대값(minimum-maximum), 기하평균(geo- metric mean; GM), 중간값(median)로 나타내었다.

ELF-MF 측정기기 간의 정도관리를 위하여 조사 시 작 전 EMDEX II를 동일한 공간에서 각 2대를 동일한 조건을 바탕으로 동시에 10회 반복 측정을 하여, 측정 기기 ELF-MF 측정값의 오차가 ±2% 이내로 이루어졌 음을 확인하였다.

3. 연구결과

3.1 어린이집 ELF-MF 노출량

Table 1은 어린이집별 ELF-MF 노출량을 분석한 결 과이다. 산술평균(Mean ± SD) 노출량은 0.59 ± 0.76 mG로 나타났으며, 기하평균 노출량은 0.33 mG로 나타 났다. ELF-MF 노출량의 각 분위수를 조사한 결과,

(3)

5% 노출량은 0.09 mG, 25% 노출량은 0.15 mG, 50%

노출량은 0.28 mG, 75% 노출량은 0.60 mG, 95% 노출 량은 2.53 mG, 99% 노출량은 2.82 mG을 보였다. 어린 이집의 ELF-MF 노출량은 우리나라 전자파인체보호 권 고기준(833 mG)와 비교하여 산술평균과 기하평균은 각 각 0.07, 0.04%으로 매우 미미한 수준으로 나타났다. 또 한 일부 역학적 연구결과에서 주장하는 장기노출 권고 기준(4 mG)과 비교하여 각각 약 15, 8.3%로 나타났다.

ELF-MF 노출량의 Range (최소-최대)는 0.08-2.82 mG로 나타났으며, 본 연구에서는 모든 어린이집이 우 리나라 전자파인체노출량기준(833 mG)과 역학적 장기 노출 권고기준(3~4 mG)을 초과하지는 않았다(Fig. 1).

우리나라의 어린이집 실내에서 ELF-MF 노출량을 조사한 연구는 매우 제한적이라 직접적인 비교는 할 수 없으나, 일부 선행연구에의 조사보다 낮은 결과를 본 연구에서는 나타내었다.

본 연구에는 약 11% 수준이 2 mG 이상에 노출이 되며, 4 mG 이상에 노출되는 어린이집은 없는 것으로 나타났다. 이러한 요인은 ELF-MF 노출량에 가장 높은 영향을 미치는 고압송전선로가 육안으로 확인할 수 없 는 거리에 있거나 어린이집 주위에 존재하지 않는 것 이 1차적으로 주요하게 기인하는 것으로 판단이 되나, 상대적으로 가전기기의 종류 및 사용빈도, 사용시간도 중요한 영향을 미치는 것으로 사료된다. 고압 가공송전 선 인접의 31개 유치원에서 ELF-MF 노출량을 조사한 연구결과에서는 평균 3.5 ± 4.6 (GM: 1.9) mG로 나타

났으며(Jung et al., 2014), 지중 송전선 어린이집 경계 지점에서 측정한 ELF-MF 노출량은 평균 1.37 ± 1.75 (GM: 0.75) mG로 나타났다(Jung et al., 2016). 2012년 선행적으로 수행한 17개의 유치원 연구에서는 ELF- MF 노출량은 3.32 ± 4.12 mG로 나타났다(Hong et al., 2008). 영국의 고압 송전선로가 지나가지 않는 일반 초 등학교의 경우에는 4,452명 중 단 3명이 2 mG 이상의 노출량이 보고되었다(UK CCSI, 1999).

3.2 어린이집 교실별 ELF-MF 노출량

Table 2는 어린이집 각 교실별 ELF-MF 노출량을 분 석한 결과, 노출량은 0.50 ± 0.71 mG (GM: 0.28 mG)로 나타났다. 최소값은 0.07 mG, 최대값은 5.39 mG로 나 타났으며, 95% 분위수와 99% 분위수는 각각 2.13 mG, 2.93 mG로 나타났다. 어린이집 교실별 ELF-MF 노출 량은 우리나라 전자파인체보호 권고기준과 일부 역학 적 연구결과에서 주장하는 장기노출 권고기준과 비교 하여 매우 미미한 수준으로 나타났다.

ELF-MF 노출량의 1개 교실을 제외한 모든 교실에 서 우리나라 전자파인체노출량기준과 역학적 장기노출 권고기준을 초과하지는 않았다(Fig. 2~3). 4 mG을 초 과한 교실(음향 청각교실)은 여타 교실보다 전기기기 가 많이 존재하며, 이로 인하여 ELF-MF 노출에 영향 을 미치는 것으로 나타났다. 그러나 대부분의 어린이집 유아들은 각자 정해진 교실에서 대부분의 시간을 생활 하므로 특수 목적 용도의 교실에서의 노출은 매우 낮 을 것으로 사료된다. 또한 본 연구에서는 어린이집에서 주로 활동하는 교실에서의 ELF-MF 노출량을 평가한 것으로, “3.1의 어린이집 ELF-MF 노출량”과 공간적 분석방법의 차이가 존재한다. 어린이집의 전체 노출량 은 교실공간과 전기기기가 상대적으로 많은 교무실(혹 은 원장실) 및 조리실 등의 공간에서 ELF-MF 측정값 을 포함하여 나타내었기 때문이다.

국외에서 선행적으로 수행한 연구에서는 79학교에 서 총 43,009개를 조사한 결과, 평균 노출량은 0.8 ± 0.6 mG로 나타났으며, 컴퓨터 교실만 2 mG 이상으로 나타 내었다. 2 mG 이상의 자기장은 대부분 마루나 천정에 서의 배전선, 전기 제품, 컴퓨터, OHP와 같은 이동성 발생원을 포함하는 기기에 영향을 받는 것으로 나타났 Table 1. Results of ELF-MF exposure level in daycare centers (unit: mG) Site aMean±bSD cRange dGM 5% 25% 50% 75% 95% 99%

(N=53) 0.59± 0.76 0.08-2.82 0.33 0.09 0.15 0.28 0.60 2.53 2.82

aMean: Arithmetic, bS.D: Arithmetic standard deviation, cRange: Minimum and maximum, dGM: Geometric mean

Fig. 1. Scatter plot of ELF-MF exposure range in daycare centers (N=53).

(4)

어린이 생활환경 공간의 ELF-MF 노출량에 관한 연구 315

실내환경 및 냄새 학회지 제15권 제4호 (2016년 12월) 다(Sun et al., 1995).

3.3 어린이집 사용 가전기기

Table 3은 어린이집 실내에서 사용하는 가전기기의 종류를 나타낸 것이다. 가장 많이 사용하는 기기는 컴 퓨터가 16.22%로 나타났으며, 그 다음이 라디오 카세

트 플레이어(13.51%), 칫솔 등 컵을 소독하는 소독기 (11.49%)로 나타났다. 그 외 TV (5.41%), 공기청정기 (6.08%), 선풍기(2.70%), 에어컨(3.38%) 등이 존재하는 것으로 나타났다. 유아들의 시청각 교육을 위하여 컴퓨 터 기기와 라디오 카세트 플레이어가 많이 사용된 것 으로 조사되었으며, 위생을 위하여 소독기를 많이 사용 Table 2. Results of ELF-MF exposure level in daycare center classroom (unit: mG) Site aMean±bSD cRange dGM 5% 25% 50% 75% 95% 99%

(N=260) 0.50± 0.71 0.07-5.39 0.28 0.08 0.12 0.26 0.46 2.13 2.93

aMean: Arithmetic, bS.D: Arithmetic standard deviation, cRange: Minimum and maximum, dGM: Geometric mean

Fig. 2. Scatter plot of ELF-MF exposure range in daycare center classroom (adjusted arithmetic value).

Fig. 3. Scatter plot of ELF-MF exposure range in daycare center classroom (adjusted median value).

Table 3. General characteristics of electrical instrument at daycare center classroom

Classify Daycare centers

N % Detailed information

TV 16 5.41 −

Air purifier 18 6.08 −

Electric fan 8 2.70 −

Sterilizer 34 11.49 Toothbrush, cup, etc

Speaker 22 7.43 −

Air-con 10 3.38

Temperature control 9 3.04 −

Intercom 12 4.05 −

Electric heater 16 5.41 −

Radio cassette (CD Player) 40 13.51 −

PC 48 16.22 Desktop

Printer 7 2.36 −

Electric wiring 13 4.39 Electric terminal, switch, socket, etc.

Electric equipment etc. 29 9.80 Project, refrigerator, fishbowl, etc.

etc. 14 4.73 -

Total 296 100.0

(5)

어린이 생활환경 공간의 ELF-MF 노출량에 관한 연구

내환경 냄새 학회154호 (2016년 12

Classify Daycare centers ELF-MF emission level (mG)

N % Detailed information Stage 0 Stage 1 Stage 2 Stage 3

TV 16 5.4 − 55.1± 5.6 (0.3-17.5) 1.4± 1.5 (0.1-5.0) 0.8± 1.6 (0-5.5) 0

Air purifier 18 6.1 − 53.1± 4.0 (0.2-15.9) 0.5± 0.8 (0-3.0) 0.2± 0.5 (0-2.0) 0

Electric fan 8 2.7 − 52.3± 2.1 (0.5-6.6) 0.6± 0.4 (0-1.1) 0.2± 0.2 (0-1.1) 0

Sterilizer 34 11.5 Toothbrush, cup 53.2± 6.3 (0-35.0) 0.8± 1.3 (0-5.4) 0.4± 1.1 (0-5.4) 0.1± 0.6

Speaker 22 7.4 − 50.8± 106.3 (0.4-506.5) 1.7 ± 2.6 (0-10.4) 0.4± 0.7 (0-3.3) 0.2± 0.7

Air-con 10 3.4 − 52.8± 3.8 (0.8-12.6) 0.2± 0.3 (0-0.7) 0.1± 0.2 (0-0.5) 0

Temperature control 9 3.0 − 10.3± 28.4 (0-86.2) 0.2± 0.5 (0-1.7) 0.1± 0.3 (0-0.8) 0

Intercom 12 4.0 − 54.1± 6.9 (0.1-18.6) 2.0± 4.6 (0-16.1) 1.6± 3.1 (0-9.4) 1.0± 1.8

Electric heater 16 5.4 − 46.8± 97.8 (1.6-405.6) 1.4± 3.6 (0.2-15.1) 0.3± 0.4 (0-1.3) 0

Radio cassette 40 13.5 CD player 14.9± 14.8 (0.7-88.4) 1.4± 1.4 (0-6.1) 0.5± 0.9 (0-5.3) 0.1± 0.3

PC 48 16.2 − 53.2± 4.0 (0.1-17.0) 0.6± 1.2 (0-6.0) 0.4± 0.9 (0-5.4) 0.2± 0.8

Printer 7 2.4 − 50.9± 1.1 (0-3.0) 0.4± 0.3 (0-0.9) 0 (0-0.1) 0

Electric wiring 13 4.4 Electric terminal, switch, socket, etc. 20.9± 34.2 (0.3-117.8) 2.1± 3.8 (0-12.4) 0.5± 1.0 (0-3.4) 0.2± 0.6 Electric equipment etc. 29 9.8 Humidifier, refrigerator, electric piano, etc.19.8± 33.9 (0.2-140.0) 2.7± 5.7 (0-22.0) 0.6± 0.9 (0-4.7) 0.1± 0.2

etc. 14 4.7 − 56.3± 6.6 (0.2-19.0) 2.9± 4.5 (0-13.6) 0.1± 0.3 (0-1.1) 0

Total 296 100 −

(6)

어린이 생활환경 공간의 ELF-MF 노출량에 관한 연구 317

실내환경 및 냄새 학회지 제15권 제4호 (2016년 12월) 하는 것으로 나타났다.

직접적인 비교가 되지는 않으나 2015년 Jung et al.

(2015)의 연구에서는 일부 초등학교의 가전기기 조사 에서는 일반교실의 경우 TV (21.43%), PC (23.21%), Printer (15.63%) 등이 있었으며, 컴퓨터실은 PC (34.15%), Speaker (19.72%), 전기 배선류(15.85%)가 주요하게 있는 것으로 나타났다.

3.4 이격거리에 따른 가전기기 ELF-MF 방출량 Table 4는 이격거리에 따른 각 가전기기의 ELF-MF 방출량을 나타낸 것이다. 0단계(Stage 0)인 직접 밀착 에서 가장 높은 ELF-MF 방출량을 보인 가전기기는 음향기기인 스피커(Speaker)로 나타났으며, 그 다음은 전열기(Electric heater), 전기선(Electric wiring) 등으로 나타났다. 각 가전기기의 ELF-MF 방출량은 각각 50.8 ± 106.3 (0.4-506.5) mG, 46.8 ± 97.8 (1.6-405.6) mG, 20.9 ± 34.2 (0.3-117.8) mG로 나타났다. 그러나 1단계 이격된 거리에서는 0단계와 비교하여 매우 낮은 ELF- MF 방출량을 보였으며, 대부분 가전기기가 2 mG 이 하로 나타났다. 2단계 이격된 거리에서는 1 mG 이하 로 나타났으며, 3단계에서는 일반 생활환경에서 노출 되는 ELF-MF 노출값과 비교하여 매우 낮은 것으로 나타났다.

이러한 결과는 선행적으로 수행한 초등학교 생활환 경의 ELF-MF 방출량 연구와 일부 유사한 경향을 보 였다. 초등학교의 ELF-MF 방출량을 조사한 결과, Stage 2 (20 cm) 이격된 거리에서는 대부분 1 mG 이하 의 방출을 보였으며, Stage 3에서는 배경수준 밑으로 감소되었다(Jung et al., 2015). 국내 14개 가전제품의 ELF-MF 방출량 연구에서는 stage 0단계에서 전자레인 지가 7.69 µT, 헤어드라이기(6.47 µT), 진공청소기(5.27 µT), TV(2.26 µT), 전기장판(1.38 µT) 등의 순으로 나 타났다(Jang et al., 2005). 또한, 본 연구결과와 마찬가 지로 거리가 멀어질수록 자기장 방출수준이 급격히 감 소하는 것으로 나타났다.

어린이집에서 주로 사용 및 보유하는 가전기기의 ELF-MF 방출량은 일부 선행연구의 전자레인지, 헤어 드라이기 등의 일부 가전기기에 비하여 상대적으로 낮 은 수준의 방출량을 보인 것으로 나타났다. 본 연구와 선행연구 결과를 고려하여 추론하여 볼 때 가전기기와 적정 이격거리를 유지하다면 어린이집에서 생활하는 유아들의 ELF-MF 노출 영향은 매우 미미할 것으로 사료된다.

그러나 본 연구에서 조사한 가전기기는 어린이집에 서 사용 및 보유하고 있는 기기를 대상으로 수행한 연

구결과이므로 전체를 평가하기에는 다소의 제한점이 존재한다. 차후 가전기기의 종류 및 특성, 사용전력량 등을 고려하여 추가적인 ELF-MF 방출 특성을 파악해 야 할 것으로 사료된다.

4. 결 론

본 연구는 우리나라 대도시에 소재한 일부 어린이집 의 실내 ELF-MF 노출량을 조사하고 내부 ELF-MF 발생기기의 종류 및 이격거리에 따른 방출량을 파악하 였다.

어린이집별 ELF-MF 노출량을 분석한 결과, 노출량 은 0.59 ± 0.76 (0.33) mG로 나타났다. 각 분위수를 조 사한 결과, 5% 노출량은 0.09 mG, 25%는 0.15 mG, 50%는 0.28 mG, 75%은 0.60 mG, 95%는 2.53 mG을 보였다. 각 교실별 ELF-MF 노출량을 분석한 결과, 노 출량은 0.50 ± 0.71 mG (GM: 0.28 mG)로 나타났다. 어 린이집 교실별 ELF-MF 노출량은 전자파인체보호 권 고기준과 일부 역학적 연구결과의 장기노출 권고기준 과 비교하여 매우 미미한 수준으로 나타났다. 4 mG을 초과한 1개 교실은 음향 청각교실로 나타났으나, 실질 적으로 어린이집 유아들의 공간별 행동 특성상 ELF- MF 노출량은 매우 낮을 것으로 사료된다.

어린이집 실내에서 가장 많이 사용하는 가전기기는 컴퓨터(16.22%)로 나타났으며, 그 다음이 라디오 카세 트 플레이어(13.51%), 칫솔 등 컵을 소독하는 소독기 (11.49%)로 나타났다. 이격거리에 따른 각 가전기기의 ELF-MF 방출량을 조사한 결과, 0단계(Stage 0)인 직접 밀착에서 가장 높은 ELF-MF 방출량을 보였다. 그러나 2단계 이상 이격거리에서는 1 mG 이하로 나타났으며, 3단계에서는 일반 생활환경에서 노출되는 ELF-MF 노 출값보다 낮은 것으로 나타났다.

그러나 어린이집에 거주하는 유아들은 서론에서 일 부 전술하였듯이 성인과 다르게 면역력이 성숙하지 못 하며, 지속적으로 신체 및 정신적으로 발달하는 단계이 다. ELF-MF는 현재까지 논란의 소지가 다분히 존재하 지만, 지속적으로 노출되었을 때 건강위해성에 영향을 미칠 개연성이 존재할 수도 있다. 따라서 일부 가전기 기의 직접 접촉 시 매우 놓은 ELF-MF에 노출될 가능 성이 존재하므로 지속적 사용 시 유아들이 접근을 방 지할 수 있도록 가전기기의 격리 및 위치 제한 등의 사 전 예방조치가 필요할 것으로 판단된다. 본 연구는 조 사 대상 어린이집의 지역에 따른 ELF-MF 노출량의 차이를 검증하지 못한 제한점이 존재하나, 어린이집과 주로 활동하는 교실, 그리고 주요 가전기기의 ELF-MF

(7)

영향 조사에 주요한 연구 목적이 있으므로 결과를 활 용하기에는 무리가 없을 것으로 판단된다. 차후 이러한 요인을 반영하여 추가적인 조사가 필요할 것으로 사료 된다.

References

Choi, S. H., Jung, J. S., ·Jeon, H. J., Kim, Y. S., Kim, N., Hong, S. C., 2015. Study on effect of exposure to electromagnetic field emitted from power line on health of elementary school students. Journal of Odor and Indoor Environment 14(3), 199-207. (in Korean with English abstract) Hong, S. C., Jung, J. S., Kim, K. Y., Park, H. J., Choi, S.

H., 2008. Evaluation of the magnetic field exposure level in 60Hz high voltage transmission lines nearby residential area.

Korean Journal of Environmental Health Sciences 34(1), 27- 33. (in Korean with English abstract)

IARC Working Group on the Evaluation of Carcinogenic Risks to Humans, World Health Organization, & International Agency for Research on Cancer, 2002. Non-ionizing Radiation: Static and extremely low-frequency (ELF) electric and magnetic fields (No. 80). World Health Organization.

IARC (International Afency for Research in Cancer), 2011.

Non-ionizing radiation, part 2: radiofrequency electromagnetic fields volume 102.

Jang, S. K., Cho, Y. S., Lee, S. J., Yoo, S. W., Jung, K. M., Lim, J. H., 2005. A survey on the EMF levels of study and electric appliances in Korea. Journal of Korean Society Occupation Environment Hygiene 15(1), 71-81. (in Korean with English abstract)

Jung, J. S., Choi, S. H., Jeon, H. J., Kim, Y. S., Hong, S.

C., 2014. Evaluation of extremely low frequency magnetic fields emission level from high voltage transmission lines.

Journal of Environmental Impact Assessment 23(5), 353- 363. (in Korean with English abstract)

Jung, J. S., Jeon, H. J., Choi, S. H., Song, H. S., Kim, Y.

S., Hong, S. C., 2015. A study of extremely low frequencymagnetic field (ELF-MF) exposure levels of korean students by daily activity pattern. Journal of The Korean Society of Living Environmental System 22(2), 228- 236. (in Korean with English abstract)

Jung, J. S., Gu, J. H., Jung, D. K., Lee, K. M., Lee, W. S., Kwon, M. H., 2016. Characteristics of ELF-MF emissions levels from underground cable lines near daycare centers in Seoul, Korea. Journal of Odor and Indoor Environment 15(2), 182-190. (in Korean with English abstract) Kabuto, M., Nitta, H., Yamamoto, S., Yamaguchi, N., Akiba, S., Honda, Y., Hagihara, J., Isaka, K., Saito, T., Ojima, T., Nakamura, Y., Mizoue, T., Ito, S., Eboshida, A., Yamazaki, S., Sokejima, S., Kurokawa, Y., Kubo, O., 2006. Childhood leukemia and magnetic fields in Japan: a case-control study of childhood leukemia and residential power-frequency magnetic fields in Japan. International Journal of Cancer 119(3), 643-650.

Linet, M. S., Hatch, E. E., Kleinerman, R. A., Robison, L.

L., Kaune, W. T., Friedman, D. R., Severson, R. K., Haines, C. M., Hartsock, C. T., Niwa, S., Wacholder, S., Tarone, R.

E., 1997. Residential exposure to magnetic fields and acute lymphoblastic leukemia in children. New England Journal of Medicine 337(1), 1-7.

London, S. J., Thomas, D. C., Bowman, J. D., Sobel, E., Cheng, T. C., Peters, J. M., 1991. Exposure to residential electric and magnetic fields and risk of childhood leukemia.

American Journal of Epidemiology 134(9), 923-937.

Savitz, D. A., Wachtel, H., Barnes, F. A., John, E. M., Tvrdik, J. G., 1988. Case-control study of childhood cancer and exposure to 60Hz magnetic fields. American journal of epidemiology 128(1), 21-38.

Sun, W. Q., Héroux, P., Clifford, T., Sadilek, V., & Hamade, F., 1995. Characterization of the 60-Hz magnetic fields in schools of the Carleton Board of Education. American Industrial Hygiene Association Journal 56(12), 12-15.

UK Childhood Cancer Study Investigators (UKCCSI). 1999.

Exposure to power-frequency magnetic fields and the risk of childhood cancer. Lancet 354(9194), 1925-1931.

Wertheimer, N., Leeper, E., 1979. Electrical wiring configurations and childhood cancer. American Journal of Epidemiology 109(3), 273-284.

World Health Organization (WHO), 2007. Extremely low frequency fields. Environmental Health Criteria. World Health Organization, Geneva, 238.

수치

Fig. 1. Scatter plot of ELF-MF exposure range in daycare centers (N=53).
Table 3. General characteristics of electrical instrument at daycare center classroom

참조

관련 문서

The objective of this study is to understand the effects of walking activity using fairy tales on the peer competence and emotional intelligence of

Objective: The purpose of this study was to investigate the effect of clinical practice satisfaction on professional self-concept among dental hygiene students.. Methods:

Objective: The purpose of this study was to investigate the relationship between the awareness of death and the ethical attitude to Do-Not-Resuscitate (DNR) among some

Objective : This study is to identify factors related to performance of hand washing in daily life for emergency Medical Technology students.. Methods : The study subjects

In order to achieve the purpose of this study, we established a theoretical assumption that the variance of achievement goal orientation will affect the

Objective: The purpose of this study was to analyze recent trend in incidence of basal cell carcinoma and squamous cell carcinoma in patients from the Gwangju City

Objective : The study aim was to estimate the prevalence of sleep disturbance and depressive symptoms as well as to examine the moderating effect of

Objective: The purpose of this study is to investigate the relationship between employee satisfaction and patient safety and quality improvement after compulsory certification