• 검색 결과가 없습니다.

An Experimental Study on the Solar Collector Efficiency for Apartment Building

N/A
N/A
Protected

Academic year: 2021

Share "An Experimental Study on the Solar Collector Efficiency for Apartment Building"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

130

>> 한국신・재생에너지학회 2011년도 추계학술대회 초록집

국내 직달일사량 자원 분석

*,**조 덕기, 윤 창열, 김 광득, 강 용 혁

Analysis of Direct Normal Insolation Resources in Korea

*,**Dok-ki Jo, Chang-Yeol Yun, Kwang-Deuk Kim, Young-Heak Kang

Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country.

We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes.

From the results, we can conclude that

1) Yearly mean 2.67 kWh/m2/day of the all day's direct normal insolation was evaluated for all days all over the 16 areas

in Korea.

2) All day's direct normal insolation of spring and summer were 2.91 kWh/m2/day and 2.23 kWh/m2/day, and for fall and

winter their values were 2.78 kWh/m2/day and 2.77 kWh/m2/day respectively. So, spring, fall and winter were higher, and

summer was lower than the yearly mean value.

Key words : 직달일사량(Direct Normal Insolation), 태양열집광시스템(Solar Thermal Concentrating System), 측정네

트워크(Measurement Network)

E-mail : *,**[email protected]

공동주택의 태양열 집열기 효율에 대한 실험적 연구

*최 병도, **김 미연

An Experimental Study on the Solar Collector Efficiency for Apartment Building

*Byungdo Choi, **Miyeon Kim

The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00).

As a result of the experiment, single evacuated tube and flat-plate collector’s efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

Key words : Solar Collector Efficiency(태양열 집열기 효율), Solar Collector(태양열 집열기 : 평판형 Flat-plate, 단일

진공관형 : Single Evacuated Tubular)

참조

관련 문서

IEA, Passive Solar Retrofitting of the University of Ioannina New School of Philosophy Building, Greece, IEA Energy Conservation in Building and Community Systems, Annex36

Table 4.1 Efficiency parameters in the flat plate solar collector using MWCNT nanofluid and water ··· 40.. Table 4.2 Efficiency parameters in the evacuated tube solar

In this study, thermal efficiency of a flat-plate solar collector and a U-tube solar collector using a CuO nanofluid and water as a working fluid was investigated according to

Therefore, in this paper, the solar array of HST is modeled as a simple model with beams and membranes, and the phenomenon of thermal induced vibration is verified and

A study on the safety analysis of steam generator tube plugging level upward in Hanbit Unit #5,6..

In SCP, a solar collector field is con- nected to a conventional distillation plant to provide thermal energy for the desalination process because fossil fuel is not

This study aims to analyze the process and the features of corporate e-Learning as a form of informal learning. For this purpose, the concept of

The following is the analytical study on W. Mazart Concerto No. It takes the form of orthodox classicism, and the 1st movement is taking the tradition structure of sonata form.