Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.
ZB 09
• • • •
ZH 09
•
ZB 12
• •
ZH 12
• •
YB 09
• • •
YB 12
• •
ZH 14
• • •
ZH 16
• •
JB 14
• • •
JB 16
• •
Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz
ZB 09 UL
• • •
YB 09 UL
• • •
Note: Valve supplied with body (PM) and coil separate. Connector to be ordered separately.
FITTINGS I A C D
3/8"
1/2"
3/4"
1"
VALVE BODY
SERIES
PM 123 V
[V] [Hz] / d.c.SEAL
V Viton
Note: 1) NP (Nominal pressure): 16 bar.
[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )
[ ] [Kg] [ ]
[bar] [bar]
3/8 123 I 13 2,40 0 5 1 Z - Y 0,510 1
1/2 123 A 13 2,40 0 5 1 Z - Y 0,540 1
3/4 123 C 20 6,00 0 3 1 J 1,230 1
1 123 D 25 7,00 0 3 1 J 1,300 1
Fittings Valve Nominal Flow Minimum Max differential Coil
Weight Notes
Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type
G
C A
B
D
SPECIFICATIONDIMENSIONSORDER CODEMATERIALS
A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)
ZB 09 ZB 12 9 12 F
YB 09 YB 12 9 12 F
ZH 09 ZH 12 9 12 H
ZH 14 ZH 16 14 16 H
JB 14 JB 16 14 16 F
Coil type Power Insulat.
[ ] [ W ] class
ELECTRICAL FEATURES
Fittings Ø G A B C D
[ ” ] [mm] [mm] [mm] [mm]
3/8 69 83 40 37,5
1/2 72 85 40 37,5
3/4 100 120 65 59
1 104 125 65 59
• Valve body:
• Seals:
• Enclosing tube:
• Plunger:
• Spring:
• Shading ring:
CW617N UNI EN 12165:98 brass stamping Viton
AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper
General description:
PARKER series 131.4 solenoid valves are direct operated.
They are used for general applications with media such as inert gases and light oils (2°E).
Series 131.4 valves are normally closed.
Temperatures:
The working temperature for media is:
maximum +140°C
minimum -10°C
The maximum ambient temperature is:
• with class “F” : +50°C;
• with class “H” : +80°C.
Application:
Series 131.4 solenoid valves are used for the automatic control of media where low flow rates are required.
Some examples of applications are:
• welding machines with controlled atmosphere;
• diesel oil burners;
• gas analysers;
• fumes analysers;
• distribution of light oils;
• measurement and control instruments;
• lubrication systems.
Coils:
For series 131.4 valves class “F” coils (155°C), encapsulated in thermoplastic containing 30% glass fiber (type KT), are available.
All the coils are for continuous service, 100% E.D.
The rated voltage tolerance is:
±10% for A.C. power supply and +10% -5% for D.C.
The “K” coil can be used on a.c. with fre-quency 50 Hz or 60 Hz (single frefre-quency) and has Faston terminals for DIN 43650A connector with protection to IP65.
Installation:
The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.
The valve body has 2 mounting holes diam.
M4 x 7 with centre distance 13 x 13.
Approvals:
• For the coils:
KH 09 115V/50Hz 230V/50Hz KT 09 115V/50Hz
220-230V/50Hz
Series 131.4
2 2 1
1
2
1
N.C.
Normally closed Coil energised - open Coil de-energised - closed
Series
131.4
Coil 24 V 115V 220-230 V 240 V 12 V 24 V
type 50 Hz* 50 Hz* 50 Hz* 50 Hz* d.c. d.c.
KT 09
• • • •
KT 10
• •
KH 09
• •
Note: Valve supplied with coil in a multipack. Connector to be ordered separately.
FITTINGS B F G
1/8"
1/4"
1/4"
COMPLETE VALVE
SERIES
VE 131.4 V
[V] [Hz] / d.c.SEAL
V Viton
Note: 1) NP (nominal pressure): 10 bar
[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )
[ ] [Kg] [ ]
[bar] [bar]
1/8 131.4 BV 2,8 0,174 0 8 6 K 0,200 1
1/4 131.4 FV 2,8 0,174 0 8 6 K 0,220 1
1/4 131.4 GV 4,0 0,318 0 2 1 K 1,220 1
Fittings Valve Nominal Flow Minimum Max differential Coil
Weight Notes
Ø Rp type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type
R B
A C
D
M4 x 7
13
13
SPECIFICATIONDIMENSIONSORDER CODEMATERIALS A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)
KT 09 KT 10 9 10 F
KH 09 - 9 - H
Coil type Power Insulat.
[ ] [ W ] class
ELECTRICAL FEATURES
Fittings Ø R A B C D
[ ” ] [mm] [mm] [mm] [mm]
1/8 32 56,5 14 35,5
1/4 38 60 16 35,5
• Valve body:
• Seals:
• Enclosing tube:
• Plunger:
• Spring:
• Shading ring:
CW617N UNI EN 12165:98 brass stamping Viton
CW614N UNI EN 12164:98
9 SMnPb23 UNI 5105 steel with nickel AISI 302 stainless steel
Copper
* models with 60 Hz availables
General description:
PARKER series 133 solenoid valves are diaphragm pilot operated and require a minimum differential pressure to operate.
They are used for applications with high flow rates and media such as water, light oils (2°E) and others, provided they are compatible with the construction materials used.
Series 133 valves are normally closed.
Temperatures:
The working temperature for media is:
maximum +90°C
minimum -10°C
with NBR seals (Buna N).
On request seals in Viton are available, for fittings ≤ G 1” for maximum working tem-perature +140°C.
The maximum ambient temperature is:
• with class “F” coils +50°C
• with class “H” coils +80°C
Application:
Series 133 solenoid valves are ideal for the automatic control of media in a wide range of applications such as:
• thermohydraulic systems;
• autoclaves;
• cooling of machine tools;
• industrial washing plants;
• evaporation towers;
• hospital equipment;
• irrigation systems;
• fire-fighting systems;
• wood-working machines;
• marble-working machines;
• molding machines;
• hygiene-health equipment.
Coils:
For series 133 valves class “F” coils (155°C), encapsulated in thermoplastic containing 30% glass fiber (types: ZB, YB), are available.
Class “H” Coils are also available (180°C), encapsulated in thermoplastic containing 40% glass fiber (type: ZH).
All the coils are for continuous service, 100% E.D.
The rated voltage tolerance is:
±10% for A.C. power supply and +10% -5% for D.C.
The “Z” and “Y” coils can be used on a.c.
with frequency 50/60 Hz (dualfrequency).
The “Z” coils have Faston terminals for DIN 43650A connectors with protection to IP65.
The “Y” coil has terminals with 2 x 1,000 mm cables with protection to IP67.
Series 133 solenoid valves are also available in a watertight version for applications where the conditions of humidity are particularly critical (type: YE 09).
Installation:
The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.
Approvals:
• For the coils:
ZB 09 115V/50-60Hz, 220-230V/50-60Hz, 240V/50-60Hz
ZH 09 24V/50-60Hz ZH 12 12VDC, 24VDC YB 09 220-230V/50-60Hz
• The coils:
ZB 09 220-230V/50-60Hz, 240V/50-60Hz YB 09 220-230V/50-60Hz
• UL Recognized Comp. coils mark:
ZB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz
YB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz
Series 133
2 1 2 1
2
1
N.C.
Normally closed Coil energised - open Coil de-energised - closed
Series
133
Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.
ZB 09
• • • •
ZH 09
•
ZB 12
• •
ZH 12
• •
YB 09
• • •
YB 12
• •
ZH 14
• • •
ZH 16
• •
YE 09
• •
Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz
ZB 09 UL
• • •
YB 09 UL
• • •
Note: Valve supplied with body (PM) and coil separate. Connector to be ordered separately. * Optional Viton for fittings up to 1”.
FITTINGS I A C D E F G
3/8" G 1/2" G 3/4" G
1" G 1 1/4" G 1 1/2" G 2" G VALVE
BODY
SERIES
PM 133
[V] [Hz] / d.c.SEAL N
*V
NBR (Buna N)
*Viton
Note: 1) NP (nominal pressure): 25 bar (from 1 1/4 to 3” PN 16 bar). 2) Slow closure version.
[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )
[ ] [Kg] [ ]
[bar] [bar]
3/8 133 I 13 3,00 0,1 20 20 Z - Y 0,550 1
1/2 133 A 13 3,00 0,1 20 20 Z - Y 0,580 1
3/4 133 C 20 8,40 0,1 20 20 Z - Y 1,020 1
1 133 D 25 9,60 0,1 20 20 Z - Y 1,080 1
1 1/4 133.2 E 35 25,20 0,1 10 10 Z - Y 3,150 1 - 2
1 1/2 133.2 F 40 30,00 0,1 10 10 Z - Y 2,900 1 - 2
2 133 G 50 37,20 0,1 10 10 Z - Y 4,300 1 - 2
Fittings Valve Nominal Flow Minimum Max differential Coil
Weight Notes
Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type
G
C
B
A
D
SPECIFICATIONDIMENSIONSORDER CODEMATERIALS
A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)
ZB 09 ZB 12 9 12 F
YB 09 YB 12 9 12 F
ZH 09 ZH 12 9 12 H
ZH 14 ZH 16 14 16 H
YE 09 - 9 - E
Coil type Power Insulat.
[ ] [ W ] class
ELECTRICAL FEATURES
Fittings
A B C D
Ø G - NPT
[ ” ] [mm] [mm] [mm] [mm]
3/8 G 69,0 92,5 40,0 37,5
1/2 G 72,0 94,5 40,0 37,5
3/4 G 100,0 100,0 65,0 37,5
1 G 104,0 105,5 65,0 37,5
1 1/4 G 145,0 127,0 102,0 37,5
1 1/2 G 145,0 127,0 102,0 37,5
2 G 173,0 141,0 118,0 37,5
• Valve body:
• Seals:
• Enclosing tube:
• Plunger:
• Spring:
• Shading ring:
CW617N UNI EN 12165:98 brass stamping NBR (Buna N) - Viton
AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper
General description:
PARKER series 133CMV solenoid valves are diaphragm pilot operated and require a minimum differential pressure to operate.
They are used for applications with high flow rates and media such as water, light oils (2°E) and others, provided they are compatible with the construction materials used.
Series 133 valves are normally closed.
Temperatures:
The working temperature for media is:
maximum +90°C
minimum -10°C
with NBR seals (Buna N).
On request seals in Viton are available, for fittings ≤G 1” for maximum working tem-perature +140°C.
The maximum ambient temperature is:
•with class “F” coils +50°C
•with class “H” coils +80°C