Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZB 09

• • • •

ZH 09

ZB 12

• •

ZH 12

• •

YB 09

• • •

YB 12

• •

ZH 14

• • •

ZH 16

• •

JB 14

• • •

JB 16

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

ZB 09 UL

• • •

YB 09 UL

• • •

Note: Valve supplied with body (PM) and coil separate. Connector to be ordered separately.

FITTINGS I A C D

3/8"

1/2"

3/4"

1"

VALVE BODY

SERIES

PM 123 V

[V] [Hz] / d.c.

SEAL

V Viton

Note: 1) NP (Nominal pressure): 16 bar.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

3/8 123 I 13 2,40 0 5 1 Z - Y 0,510 1

1/2 123 A 13 2,40 0 5 1 Z - Y 0,540 1

3/4 123 C 20 6,00 0 3 1 J 1,230 1

1 123 D 25 7,00 0 3 1 J 1,300 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

G

C A

B

D

SPECIFICATIONDIMENSIONSORDER CODEMATERIALS

A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZB 09 ZB 12 9 12 F

YB 09 YB 12 9 12 F

ZH 09 ZH 12 9 12 H

ZH 14 ZH 16 14 16 H

JB 14 JB 16 14 16 F

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

3/8 69 83 40 37,5

1/2 72 85 40 37,5

3/4 100 120 65 59

1 104 125 65 59

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping Viton

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

General description:

PARKER series 131.4 solenoid valves are direct operated.

They are used for general applications with media such as inert gases and light oils (2°E).

Series 131.4 valves are normally closed.

Temperatures:

The working temperature for media is:

maximum +140°C

minimum -10°C

The maximum ambient temperature is:

• with class “F” : +50°C;

• with class “H” : +80°C.

Application:

Series 131.4 solenoid valves are used for the automatic control of media where low flow rates are required.

Some examples of applications are:

• welding machines with controlled atmosphere;

• diesel oil burners;

• gas analysers;

• fumes analysers;

• distribution of light oils;

• measurement and control instruments;

• lubrication systems.

Coils:

For series 131.4 valves class “F” coils (155°C), encapsulated in thermoplastic containing 30% glass fiber (type KT), are available.

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “K” coil can be used on a.c. with fre-quency 50 Hz or 60 Hz (single frefre-quency) and has Faston terminals for DIN 43650A connector with protection to IP65.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

The valve body has 2 mounting holes diam.

M4 x 7 with centre distance 13 x 13.

Approvals:

• For the coils:

KH 09 115V/50Hz 230V/50Hz KT 09 115V/50Hz

220-230V/50Hz

Series 131.4

2 2 1

1

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed

Series

131.4

Coil 24 V 115V 220-230 V 240 V 12 V 24 V

type 50 Hz* 50 Hz* 50 Hz* 50 Hz* d.c. d.c.

KT 09

• • • •

KT 10

• •

KH 09

• •

Note: Valve supplied with coil in a multipack. Connector to be ordered separately.

FITTINGS B F G

1/8"

1/4"

1/4"

COMPLETE VALVE

SERIES

VE 131.4 V

[V] [Hz] / d.c.

SEAL

V Viton

Note: 1) NP (nominal pressure): 10 bar

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

1/8 131.4 BV 2,8 0,174 0 8 6 K 0,200 1

1/4 131.4 FV 2,8 0,174 0 8 6 K 0,220 1

1/4 131.4 GV 4,0 0,318 0 2 1 K 1,220 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø Rp type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

R B

A C

D

M4 x 7

13

13

SPECIFICATIONDIMENSIONSORDER CODEMATERIALS A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

KT 09 KT 10 9 10 F

KH 09 - 9 - H

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø R A B C D

[ ” ] [mm] [mm] [mm] [mm]

1/8 32 56,5 14 35,5

1/4 38 60 16 35,5

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping Viton

CW614N UNI EN 12164:98

9 SMnPb23 UNI 5105 steel with nickel AISI 302 stainless steel

Copper

* models with 60 Hz availables

General description:

PARKER series 133 solenoid valves are diaphragm pilot operated and require a minimum differential pressure to operate.

They are used for applications with high flow rates and media such as water, light oils (2°E) and others, provided they are compatible with the construction materials used.

Series 133 valves are normally closed.

Temperatures:

The working temperature for media is:

maximum +90°C

minimum -10°C

with NBR seals (Buna N).

On request seals in Viton are available, for fittings ≤ G 1” for maximum working tem-perature +140°C.

The maximum ambient temperature is:

• with class “F” coils +50°C

• with class “H” coils +80°C

Application:

Series 133 solenoid valves are ideal for the automatic control of media in a wide range of applications such as:

• thermohydraulic systems;

• autoclaves;

• cooling of machine tools;

• industrial washing plants;

• evaporation towers;

• hospital equipment;

• irrigation systems;

• fire-fighting systems;

• wood-working machines;

• marble-working machines;

• molding machines;

• hygiene-health equipment.

Coils:

For series 133 valves class “F” coils (155°C), encapsulated in thermoplastic containing 30% glass fiber (types: ZB, YB), are available.

Class “H” Coils are also available (180°C), encapsulated in thermoplastic containing 40% glass fiber (type: ZH).

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “Z” and “Y” coils can be used on a.c.

with frequency 50/60 Hz (dualfrequency).

The “Z” coils have Faston terminals for DIN 43650A connectors with protection to IP65.

The “Y” coil has terminals with 2 x 1,000 mm cables with protection to IP67.

Series 133 solenoid valves are also available in a watertight version for applications where the conditions of humidity are particularly critical (type: YE 09).

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Approvals:

• For the coils:

ZB 09 115V/50-60Hz, 220-230V/50-60Hz, 240V/50-60Hz

ZH 09 24V/50-60Hz ZH 12 12VDC, 24VDC YB 09 220-230V/50-60Hz

• The coils:

ZB 09 220-230V/50-60Hz, 240V/50-60Hz YB 09 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

ZB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

YB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series 133

2 1 2 1

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed

Series

133

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZB 09

• • • •

ZH 09

ZB 12

• •

ZH 12

• •

YB 09

• • •

YB 12

• •

ZH 14

• • •

ZH 16

• •

YE 09

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

ZB 09 UL

• • •

YB 09 UL

• • •

Note: Valve supplied with body (PM) and coil separate. Connector to be ordered separately. * Optional Viton for fittings up to 1”.

FITTINGS I A C D E F G

3/8" G 1/2" G 3/4" G

1" G 1 1/4" G 1 1/2" G 2" G VALVE

BODY

SERIES

PM 133

[V] [Hz] / d.c.

SEAL N

*V

NBR (Buna N)

*Viton

Note: 1) NP (nominal pressure): 25 bar (from 1 1/4 to 3” PN 16 bar). 2) Slow closure version.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

3/8 133 I 13 3,00 0,1 20 20 Z - Y 0,550 1

1/2 133 A 13 3,00 0,1 20 20 Z - Y 0,580 1

3/4 133 C 20 8,40 0,1 20 20 Z - Y 1,020 1

1 133 D 25 9,60 0,1 20 20 Z - Y 1,080 1

1 1/4 133.2 E 35 25,20 0,1 10 10 Z - Y 3,150 1 - 2

1 1/2 133.2 F 40 30,00 0,1 10 10 Z - Y 2,900 1 - 2

2 133 G 50 37,20 0,1 10 10 Z - Y 4,300 1 - 2

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

G

C

B

A

D

SPECIFICATIONDIMENSIONSORDER CODEMATERIALS

A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZB 09 ZB 12 9 12 F

YB 09 YB 12 9 12 F

ZH 09 ZH 12 9 12 H

ZH 14 ZH 16 14 16 H

YE 09 - 9 - E

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings

A B C D

Ø G - NPT

[ ” ] [mm] [mm] [mm] [mm]

3/8 G 69,0 92,5 40,0 37,5

1/2 G 72,0 94,5 40,0 37,5

3/4 G 100,0 100,0 65,0 37,5

1 G 104,0 105,5 65,0 37,5

1 1/4 G 145,0 127,0 102,0 37,5

1 1/2 G 145,0 127,0 102,0 37,5

2 G 173,0 141,0 118,0 37,5

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping NBR (Buna N) - Viton

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

General description:

PARKER series 133CMV solenoid valves are diaphragm pilot operated and require a minimum differential pressure to operate.

They are used for applications with high flow rates and media such as water, light oils (2°E) and others, provided they are compatible with the construction materials used.

Series 133 valves are normally closed.

Temperatures:

The working temperature for media is:

maximum +90°C

minimum -10°C

with NBR seals (Buna N).

On request seals in Viton are available, for fittings ≤G 1” for maximum working tem-perature +140°C.

The maximum ambient temperature is:

•with class “F” coils +50°C

•with class “H” coils +80°C

관련 문서