General description:

PARKER series 169.1 solenoid valves are diaphragm pilot operated and therefore require a minimum differential pressure to operate.

They are used for air applications, inclu-ding high operating frequencies. The diaphragm is made of plastic with a fabric reinforcement.

The valves of the series 169.1 are normally open.

Temperatures:

The working temperature for media is:

maximum +90°C

minimum -10°C

The maximum ambient temperature is:

•with class “F” coils +50°C

•with class “H” coils +80°C

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZB 14

• • • •

ZB 16

• •

YB 14

• • •

YB 16

• •

ZH 14

• • •

ZH 16

• •

Note: Valve supplied with body (PM) and coil separate. Connector to be ordered separately.

FITTINGS I A C D

3/8"

1/2"

3/4"

1"

VALVE BODY

SERIES

PM 169.1 N

[V] [Hz] / d.c.

Note: 1) NP (nominal pressure): 25 bar.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

3/8 169.1 I 13 2,0 0,5 16 16 Z - Y 0,560 1

1/2 169.1 A 13 2,5 0,5 16 16 Z - Y 0,590 1

3/4 169.1 C 20 7,0 0,5 16 16 Z - Y 1,250 1

1 169.1 D 25 8,0 0,5 16 16 Z - Y 1,110 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

C

B

A

D

G

SPECIFICATIONDIMENSIONSORDER CODEMATERIALS A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZB 14 ZB 16 14 16 F

YB 14 YB 16 14 16 F

ZH 14 ZH 16 14 16 H

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

3/8 69,0 101,0 40,0 43

1/2 72,0 103,0 40,0 43

3/4 100,0 108,5 65,0 43

1 104,0 114,0 65,0 43

SEAL

N NBR (Buna N)

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping NBR (Buna N)

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

General description:

PARKER series 173 solenoid valves are diaphragm pilot operated and therefore require a minimum differential pressure to operate.

They are used for general applications with media such as water, air, light oils (2°E) and inert gases, provided they are com-patible with the construction materials used.

Series 173 valves are normally closed.

They are compact, with high flow rates and low power consumption.

Temperatures:

The working temperature for media is:

maximum +90°C

minimum -10°C

The maximum ambient temperature is:

+50°C

Application:

Series 173 solenoid valves are ideal for the automatic control of media in a wide range of applications such as:

• Computerised controls;

• Cooling systems for machine tools;

• Dry-cleaning machines;

• Autoclaves;

• Compressed air systems;

• Car wash systems;

• Hygiene-health systems;

• Tanning industry.

Coils:

Series 173 valves are available with class

“F” coils (155°C) with thermoplastic insula-tion, reinforced with 30% glassofibre.

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “W” coil can be used on a.c. with fre-quency of 50/60Hz (dualfrefre-quency) and has Faston terminals for DIN 43650B connec-tors with protection to IP65.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Approvals:

• For the coil:

WB 4,5 115V/50-60Hz, 220-230V/50-60Hz

• For the coil:

WB 4,5 115V/50-60Hz, 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

WB 4,5 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series 173

2 2 1

1

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed Series

173

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

WB 4,5

• • • •

WB 5,0

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

WB 4,5 UL

• • •

Note: Valve supplied with body (PM) and coil separate. Connector to be ordered separately.

FITTINGS I A

3/8"

1/2"

VALVE BODY

SERIES

PM 173 N

[V] [Hz] / d.c.

Note: 1) NP (nominal pressure): 25 bar.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

3/8 173 I 13 3,00 0,35 15 15 W 0,435 1

1/2 173 A 13 3,50 0,35 15 15 W 0,410 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

B

A

G

C

D

SPECIFICATIONDIMENSIONSORDER CODEMATERIALS A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

WB 4,5 WB 5,0 4,5 5,0 F

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

3/8 60 86 40 36

1/2 60 86 40 36

SEAL

N NBR (Buna N)

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping NBR (Buna N)

CW614N UNI EN 12164:98 AISI 430F stainless steel AISI 302 stainless steel Copper

General description:

PARKER series N74 solenoid valves have direct action and therefore do not require a minimum differential pressure to operate.

They are used for general applications, when small overall dimensions and low consumption are required, with media such as water, air, light oils (2°E) and inert gases, provided they are compatible with the construction materials used.

Series N74 valves are normally closed.

For large orders, valves are available on request with manual operator.

Temperatures:

The working temperature for media is:

maximum +140°C

minimum -10°C

The maximum ambient temperature is:

+50°C

Application:

Series N74 solenoid valves are ideal for the automatic control of media with low flow rates.

Some typical application examples:

•Espresso coffee machines;

•Sterilisers;

•Compressed air systems;

•Welding machines;

•Wood-working machines;

•Electrical medical equipment;

•Shoe-manufacturing machines.

Coils:

For series N74 valves the WB class “F”

coil (155°C), encapsulated in thermoplastic containing 30% glass fiber, is used.

The coil is for continuous service, 100%

E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “W” coil can be used on a.c. with fre-quency of 50/60Hz (dualfrefre-quency) and has Faston terminals for DIN 43650B connec-tors with protection to IP65.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

The series N74 valves with the code .4 are fitted with M4 x 7 mounting holes on the valve body with centre distance 18 x 18 mm.

Approvals:

• For the coil:

WB 4,5 115V/50-60Hz, 220-230V/50-60Hz

• For the coil:

WB 4,5 115V/50-60Hz, 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

WB 4,5 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series N74

2 2 1

1

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed Series

N74

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

WB 4,5

• • • •

WB 5,0

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

WB 4,5 UL

• • •

Note: Valve supplied with coil in a multipack. Connector to be ordered separately.

FITTINGS A B F W

1/8"

1/8"

1/8 "

1/4"

COMPLETE VALVE

SERIES

VE N74.4 V

[V] [Hz] / d.c.

SEAL

V Viton

Note: 1) NP (nominal pressure): 25 bar.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

1/8 N74.4 A 1,5 0,06 0 20 15 W 0,14 1

1/8 N74.4 B 2 0,11 0 15 10 W 0,14 1

1/8 N74.4 F 2,5 0,14 0 10 6 W 0,14 1

1/4 N74.4 W 2,5 0,14 0 10 6 W 0,15 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

A B

G E E

1 2

C A

E

G B

E

SPECIFICATIONDIMENSIONSORDER CODEMATERIALS A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

WB 4,5 WB 5,0 4,5 5,0 F

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

1/8 30 56 14 36

1/4 30 58,5 18 36

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping Viton

AISI 303 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

General description:

PARKER series N79 solenoid valves have direct action and are used in systems for pressurisation and automatic discharge of media when small overall dimensions and low power consumption are required. They are suitable for general applications with media such as water, air, light oils (2°E) and inert gases, provided they are compa-tible with the construction materials used.

Series N79 valves are normally closed.

For large orders, valves are available on request with manual operator.

Temperatures:

The working temperature for media is:

maximum +140°C

minimum -10°C

The maximum ambient temperature is:

+50°C

Application:

Series N79 solenoid valves are ideal for automatic control of media where low flow rates are required.

Some typical application examples:

• Exhaust gas analysers;

• Sterilisers;

• Scientific equipment;

• Electrical medical equipment;

• Automatic dispensers;

• Pilot valves.

Coils:

For series N79 valves the WB class “F” coil (155°C), encapsulated in thermoplastic containing 30% glass fiber, is used.

The coil is for continuous service, 100%

E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “W” coil can be used on a.c. with fre-quency of 50/60Hz (dualfrefre-quency) and has Faston terminals for DIN 43650B connec-tor with protection to IP65.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Approvals:

• Coil certification:

WB 4,5 115V/50-60Hz, 220-230V/50-60Hz

• For the coil:

WB 4,5 115V/50-60Hz, 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

WB 4,5 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series N79

2 1

0

2 1

0

2 1

0

N.C.

Normally closed Coil energised - open Coil de-energised - closed

Series

N79

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

WB 4,5

• • • •

WB 5,0

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

WB 4,5 UL

• • •

Note: Valve supplied with coil in a multipack. Connector to be ordered separately.

FITTINGS I A

1/8"

1/8"

COMPLETE VALVE

SERIES

VE N79.4 V

[V] [Hz] / d.c.

SEAL

V Viton

Note: 1) NP (nominal pressure): 25 bar. (2) * Discharge diameter.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

1/8 N79.4 I 1,2 (1,6)* 0,04 0 10 10 W 0,14 1

1/8 N79.4 A 1,5 (1,6)* 0,05 0 7 7 W 0,14 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

SPECIFICATIONDIMENSIONSORDER CODEMATERIALS A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

WB 4,5 WB 5,0 4,5 5,0 F

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

1/8 30 56 14 35

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping Viton

AISI 303 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

D

G B

A C

Ø M4 x 6 8

90°

and High

Temperatures

Series 126 Series 128 Series 133…H Series 135 Series 140.2 Series 156.2 Series 158 Series 161.4

NC NC NC NC NC NC NC NC

NC = normally closed

pages 74-75 76-77 78-79 80-81 82-83 84-85 86-87 88-89

The numbers in [bar] in the table indicate the M.O.P.D. values (maximum operating differential pressure). The columns refer to the type of fittings and the type of power supply, the rows refer to the valve series.

a.c. [bar]

d.c. [bar]

a.c. [bar]

d.c. [bar]

a.c. [bar]

d.c. [bar]

a.c. [bar]

d.c. [bar]

a.c. [bar]

d.c. [bar]

a.c. [bar]

d.c. [bar]

a.c. [bar]

d.c. [bar]

a.c. [bar]

d.c. [bar]

a.c. [bar]

G=3/8”G=1/2”G=3/4”G=1 ”G=1 1/4”G=1 1/2”FITTINGS TYPE

G = 1/8”G = 1/4” Series 126 Series 128 Series 133…H Series 135 Series 140.2 Series 156.2 Series 158 Series 161.4

20 10 16

20 10

20 10 16

6÷10 4÷10 10

10 10 1010

20÷30 10

series 128: 32 mm flange: a.c. 10 bar - d.c 10 bar 1010101020 10

20 10 14

20 10

20 10 14

20 10

General description:

PARKER series 126 solenoid valves are direct operated and do not require a mini-mum differential pressure to operate.

They are used with steam and superhea-ted water.

Series 126 valves are normally closed.

Temperatures:

The working temperature for media is:

+140°C for models with an ethylene propy-lene seal (EPDM) and +180°C for the ver-sion with a Teflon seal (PTFE).

The minimum temperature of media is -10°C The maximum ambient temperature is:

with class “F” coils +50°C with class “H” coils +80°C

Application:

Series 126 solenoid valves are ideal for automatic control of steam and superheated water in applications such as:

• Steam generators;

• Sterilisers;

• Autoclaves;

• Espresso coffee machines;

• Drink dispensers;

• Furnaces;

• Ironing boards and presses.

Coils:

For series 126 valves class “F” coils (155°C) are available encapsulated in ther-moplastic containing 30% glass fiber (types ZB, YB) and class “H” coils (180°C) are available encapsulated in thermoplastic containing 40% of glass fiber (type ZH).

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “Z” and “Y” coils can be used on a.c.

with a frequency of 50/60 Hz (dualfre-quency).

The “Z” coils have Faston terminals for DIN 43650A connectors with protection to IP65.

The “Y” coil has terminals with 2 x 1,000 mm cables with protection to IP67.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

The valve body has a M4 x 8 mounting hole.

Approvals:

• For the coils:

ZB 09 115V/50-60Hz, 220-230V/50-60Hz, 240V/50-60Hz

ZH 09 24V/50-60Hz ZH 12 12V DC, 24V DC YB 09 220-230V/50-60Hz

• For the coils:

ZB 09 220-230V/50-60Hz, 240V/50-60Hz YB 09 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

ZB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

YB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series 126

2 1 2

1

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed

Series

126

SEAL H

T

EPDM PTFE (Teflon)

Coil 24 V 115V 220-230 V 240 V 12 V 24 V

type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZB 09

• • • •

ZH 09

ZB 12

• •

ZH 12

• •

YB 09

• • •

YB 12

• •

ZH 14

• • •

ZH 16

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

ZB 09 UL

• • •

YB 09 UL

• • •

Note: Valve supplied with body (PM) and coil separate. Connectors to be ordered separately.

FITTINGS Y 1/4"

VALVE BODY

SERIES

PM 126 Y

[V] [Hz]/d.c.

Note: 1) Maximum pressure for steam 4 bar (140°C). 2) NP (nominal pressure): 25 bar.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

1/4 126 YH 3,0 0,25 0 10 6 YB - ZB 0,33 1 - 2

1/4 126 YT 3,0 0,25 0 10 10 ZH 0,33 2

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

G B

A C

D

SPECIFICATIONDIMENSIONSORDERCODEMATERIALS

A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZB 09 ZB 12 9 12 F

YB 09 YB 12 9 12 F

ZH 09 ZH 12 9 12 F

ZH 14 ZH 16 14 16 H

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

1/4 40 75,5 18 37,5

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

• Fitted sit:

CW617N UNI EN 12165:98 brass stamping EPDM - PTFE (Teflon)

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

AISI 304 stainless steel

General description:

PARKER series 128 solenoid valves are direct operated and do not require a mini-mum differential pressure to operate.

They are used for superheated water.

Series 128 valves are normally closed.

The inlet and outlet fittings are situated on the mounting flange and enclosing tube.

Temperatures:

The working temperature for media is:

maximum +140°C

minimum -30°C (Ruby)

minimum -10°C (FKM)

The maximum ambient temperature is:

• with class “F” coils +50°C

• with class “H” coils +80°C

Application:

Series 128 solenoid valves are ideal for automatic control of superheated water for dispensing espresso coffee.

Models are available with various seals and fitting configurations for maximum flexibility of application and installation.

Some typical application examples:

• Espresso coffee machines, for bars;

• Espresso coffee machines, for the home;

• Automatic dispensers.

Coils:

For series 128 valves class “F” coils (155°C) are available encapsulated in ther-moplastic containing 30% glass fiber, (ZB, YB types). Class “H” coils (180°C) are avai-lable encapsulated in thermoplastic contai-ning 40% of glass fiber ( ZH type).

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “Z” and “Y” coils can be used on a.c.

with a frequency of 50/60 Hz (dualfre-quency).

The “Z” coils have Faston terminals for DIN 43650A connectors with protection to IP65.

The “Y” coil has terminals with 2 x 1,000 mm cables with protection to IP67.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Approvals:

• For the coils:

ZB 09 115V/50-60Hz, 220-230V/50-60Hz, 240V/50-60Hz

ZH 09 24V/50-60Hz ZH 12 12VDC, 24VDC YB 09 220-230V/50-60Hz

• For the coils:

ZB 09 220-230V/50-60Hz,240V/50-60Hz YB 09 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

ZB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

YB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series 128

1 2 0

1 2 0

2 1

0

N.C.

Normally closed Coil energised - open Coil de-energised - closed

Series

128

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZB 09

• • • •

ZH 09

ZB 12

• •

ZH 12

• •

YB 09

• • •

YB 12

• •

ZH 14

• • •

ZH 16

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

ZB 09 UL

• • •

YB 09 UL

• • •

Note: Valves supplied with coils in a multipack. Connectors to be ordered separately.

DISCHARGE FITTINGS I G

conical cylindrical VALVE

BODY

SERIES

PM 128

[V] [Hz]/d.c.

SEAL R V

Ruby Viton Note: 1) NP (nominal pressure): 25 bar.

2) Maximum static pressure 14.5 bar (for Viton sealing, maximum static pressure: 12 bar). (*) Diameter of the discharge.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

- 128 I 1,3 - (2,5)* 0,070 0 10 10 Z - Y 0,310 1 - 2

- 128 G 1,3 - (2,5)* 0,070 0 10 10 Z - Y 0,310 1 - 2

- 128 I-UL 1,3 - (2,5)* 0,070 0 10 10 Z - UL 0,310 1 - 2

- 128 G-UL 1,3 - (2,5)* 0,070 0 10 10 Z - UL 0,310 1 - 2

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

B

D

A C

SPECIFICATIONDIMENSIONSORDERCODE

A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZB 09 ZB 12 9 12 F

YB 09 YB 12 9 12 F

ZH 09 ZH 12 9 12 H

ZH 14 ZH 16 14 16 H

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

TYPE A B C D

[ ” ] [mm] [mm] [mm] [mm]

128 I 32 66 32 45,5

128 G* 32 63,5 32 43

*drg. 2

MATERIALS

C

B

D

A

drg. 1 drg. 2

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

• Fitted sit:

CW617N UNI EN 12165:98 brass stamping Ruby - Viton

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

AISI 304 stainless steel

General description:

PARKER series 133H solenoid valves are diaphragm pilot operated and require a minimum differential pressure to operate.

They are used for steam and superheated water where high flow rates are required.

Series 133H valves are normally closed.

Temperatures:

The working temperature for media is:

maximum +140°C

minimum -10°C

The maximum ambient temperature is:

• with coils in class “F” +50°C

• with coils in class “H” +80°C

Application:

Series 133 H solenoid valves are ideal for the automatic control of high temperature water and steam.

Some typical application examples:

• Steam generators;

• Sterilisation systems;

• Industrial washing machines;

• Washing systems;

• Furnaces;

• Boiling systems;

• Autoclaves.

Coils:

For series 133H valves class “F” coils (155°C) are available encapsulated in ther-moplastic containing 30% glass fiber (types ZB, YB) and class “H” coils (180°C) are available encapsulated in thermoplastic containing 40% of glass fiber (ZH type).

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5% for D.C.

The “Z” and “Y” coils can be used on a.c.

with a frequency of 50/60 Hz (dualfre-quency).

The “Z” coils have Faston terminals for DIN 43650A connectors with protection to IP65.

The “Y” coil has terminals with 2 x 1,000 mm cables with protection to IP67.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Approvals:

• For the coils:

ZB 09 115V/50-60Hz, 220-230V/50-60Hz, 240V/50-60Hz

ZH 09 24V/50-60Hz ZH 12 12V DC, 24V DC YB 09 220-230V/50-60Hz

• For the coils:

ZB 09 220-230V/50-60Hz, 240V/50-60Hz YB 09 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

ZB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz YB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series 133 ... H

2 1 2 1

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed

Series

133 ... H

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZB 09

• • • •

ZH 09

ZB 12

• •

ZH 12

• •

YB 09

• • •

YB 12

• •

ZH 14

• • •

ZH 16

• •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

ZB 09 UL

• • •

YB 09 UL

• • •

Note: Valve supplied with body (PM) and coil separate. Connectors to be ordered separately.

FITTINGS I A C D

• 2 E

• 2 F G

3/8"

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

VALVE BODY

SERIES

PM 133 H

[V] [Hz]/d.c.

SEAL

H EPDM

G

C

B

A

D

DIMENSIONSORDERCODE

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

3/8 69 92,5 40 37,5

1/2 72 94,5 40 37,5

3/4 100 100,0 65 37,5

1 104 105,5 65 37,5

1 1/4 145 127,0 102 37,5

1 1/2 145 127,0 102 37,5

2 173 141,0 118 37,5

MATERIALS

A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZB 09 ZB 12 9 12 F

YB 09 YB 12 9 12 F

ZH 09 ZH 12 9 12 H

ZH 14 ZH 16 14 16 H

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Note: 1) NP (nominal pressure): 25 bar. 2) Maximum pressure for steam: 4 bar (140°C).

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

3/8 133 I 13 3,00 0,1 20 20 Z - Y 0,550 1 - 2

1/2 133 A 13 3,00 0,1 20 20 Z - Y 0,580 1 - 2

3/4 133 C 20 8,40 0,1 20 20 Z - Y 1,020 1 - 2

1 133 D 25 9,60 0,1 20 20 Z - Y 1,080 1 - 2

1 1/4 133.2 E 35 25,20 0,1 10 10 Z - Y 3,150 1 - 2

1 1/2 133.2 F 40 30,00 0,1 10 10 Z - Y 2,900 1 - 2

2 133 G 50 37,20 0,1 10 10 Z - Y 4,300 1 - 2

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

SPECIFICATION

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

CW617N UNI EN 12165:98 brass stamping EPDM

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

General description:

PARKER series 135 solenoid valves are diaphragm pilot operated and therefore require a minimum differential pressure to operate.

They are used for steam and superheated water.

Electrical components are insulated from the moving parts in contact with the media and therefore series 135 valves are particu-larly suitable for demanding applications.

Series 135 valves are normally closed.

Temperatures:

The working temperature for media is:

maximum +180°C

minimum -30°C

The maximum ambient temperature is:

+80°C

Coils:

For series 135 valves class “F” coils (155°C) are available encapsulated in ther-moplastic containing 40% of glass fiber (types ZH).

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5%. for D.C.

The “Z” coil can be used on a.c. with a fre-quency of 50/60 Hz (dual frefre-quency) and has Faston terminals for DIN 43650A con-nectors with protection to IP65.

Application:

Series 135 solenoid valves are ideal for automatic control of steam and superhea-ted water in a wide range of applications such as those listed below.

• Dry-cleaning systems;

• Steam generators;

• Laundry systems;

• Sterilisers;

• Autoclaves;

• Plant food industry;

• Steam presses;

• Drying systems;

• Catering systems.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Series 135

1 2 1 2

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed Series

135

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZH 14

• • •

ZH 16

Note: Valve supplied with body(PM) and coil separate. Connectors to be ordered separately.

FITTINGS I A C D

3/8"

1/2"

3/4"

1"

VALVE BODY

SERIES

PM 135 T

[V] [Hz]/d.c.

SEAL

T PTFE

(Teflon) Note: 1) NP (nominal pressure): 25 bar.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

3/8 135 I 16 4,7 0,5 10 10 Z 1,150 1

1/2 135 A 16 4,7 0,5 10 10 Z 1,000 1

3/4 135 C 27 11,6 0,5 10 10 Z 3,500 1

1 135 D 27 11,6 0,5 10 10 Z 3,200 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

A

G B

D

C

SPECIFICATIONDIMENSIONSORDERCODE

A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZH 14 ZH 16 14 16 H

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

3/8 67 127 58 65,5

1/2 67 127 58 65,5

3/4 98,5 177 82 96

1 98,5 177 82 96

MATERIALS

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

• Fitted sit:

CW617N UNI EN 12165:98 brass stamping PTFE (Teflon)

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

AISI 304 stainless steel

General description:

PARKER series 140.2 solenoid valves are direct operated and do not require a mini-mum differential pressure to operate.

They are used for general applications with media such as steam and superheated water.

Series 140.2 valves are normally closed.

Temperatures:

The working temperature for media is:

maximum +140°C

minimum -30°C

The maximum ambient temperature is:

with class “F” coils +50°C with class “H” coils +80°C

Application:

Series 140.2 solenoid valves are particularly suitable for small flow rates of steam or superheated water.

Some typical application examples:

• Espresso coffee machines;

• Automatic dispensers;

• Sterilisers;

• Autoclaves.

Coils:

For series 140.2 valves class “F” coils (155°C) are available encapsulated in ther-moplastic containing 30% glass fiber (types: ZB, YB) and class “H” coils (180°C) series are available encapsulated in ther-moplastic material containing 40% of glass fiber (type ZH).

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply and +10% -5%. for D.C.

The “Z” and “Y” coils can be used on a.c.

with a frequency of 50/60 Hz (dualfre-quency).

The “Z” coils have Faston terminals for DIN 43650A connectors with protection to IP65.

The “Y” coil has terminals with 2 x 1,000 mm cables with protection to IP67.

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Approvals:

• For the coils:

ZB 09 115V/50-60Hz, 220-230V/50-60Hz, 240V/50-60Hz

ZH 09 24V/50-60Hz YB 09 220-230V/50-60Hz

• For the coils:

ZB 09 220-230V/50-60Hz, 240V/50-60Hz YB 09 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

ZB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz YB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series 140.2

2 2 1

1

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed

Series

140.2

Coil 24 V 115V 220-230 V 240 V 12 V 24 V type 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz d.c. d.c.

ZB 09

• • • •

YB 09

• • •

ZH 09

ZH 14

• • •

Coil type 24 V / 60 Hz 110-120 V / 60 Hz 208-240 V / 60 Hz

ZB 09 UL

• • •

YB 09 UL

• • •

Note: Valve supplied with body (PM) and coil separate. Connectors to be ordered separately.

VALVE BODY

SERIES

PM 140.2

[V] [Hz]/d.c.

Note: 1) NP (nominal pressure): 64 bar.

[ ” ] [ ] [mm] [m3/h] [bar] in A.C.( ~) in D.C.( = )

[ ] [Kg] [ ]

[bar] [bar]

1/8 140.2 HH 2,5 0,19 0 20 - Z - Y 0,320 1

1/8 140.2 IR 2,5 0,19 0 10 - Z - Y 0,320 1

Fittings Valve Nominal Flow Minimum Max differential Coil

Weight Notes

Ø G type orifice Ø coefficient Kv pressure pressure (M.O.P.D.) type

G B

A C

D

SPECIFICATIONDIMENSIONSORDERCODE

A.C.( ~) D.C.( =) A.C.( ~) D.C.( =)

ZB 09 - 9 - F

YB 09 - 9 - F

ZH 09 - 9 - H

ZH 14 - 14 - H

Coil type Power Insulat.

[ ] [ W ] class

ELECTRICAL FEATURES

Fittings Ø G A B C D

[ ” ] [mm] [mm] [mm] [mm]

1/8 30 68 14 37,5

MATERIALS

SEAL HH

IR

EPDM Ruby

• Valve body:

• Seals:

• Enclosing tube:

• Plunger:

• Spring:

• Shading ring:

• Fitted sit:

CW617N UNI EN 12165:98 brass stamping Ruby - EPDM

AISI 304 stainless steel AISI 430F stainless steel AISI 302 stainless steel Copper

AISI 304 stainless steel

General description:

PARKER series 156.2 solenoid valves are diaphragm pilot operated and require a minimum differential pressure to operate.

They are used for general applications with media such as steam and superheated water.

Series 156.2 valves are normally closed .

Temperatures:

The working temperature for media is:

maximum +160°C

minimum -30°C

The maximum ambient temperature is:

with class coils “F” +50°C with class coils “H” +80°C

Application:

Series 156.2 solenoid valves are ideal for automatic control of steam and superheated water in a wide range of applications such as:

• Sterilisers;

• Ironing machines;

• Hospital equipment;

• Tanning plants;

• Tobacco plants.

Coils:

For series 156.2 valves class “F” coils (155°C) are available encapsulated in ther-moplastic containing 30% glass fiber (types: ZB, YB) and class “H” coils (180°C) are available encapsulated in thermoplastic containing 40% glass fiber (type ZH).

All the coils are for continuous service, 100% E.D.

The rated voltage tolerance is:

±10% for A.C. power supply

The “Z” and “Y” coils can be used on a.c.

with a frequency of 50/60 Hz (dualfre-quency).

The “Z” coils have Faston terminals for DIN 43650A connectors with protection to IP65.

The “Y” coil has terminals with 2 x 1,000 mm cables with protection to IP67 .

Installation:

The valves can be mounted in any position without jeopardising their operation. It is however advisable to install them with the coil in a vertical position above the body.

Approvals:

• For the coils:

ZB 09 115V/50-60Hz, 220-230V/50-60Hz, 240V/50-60Hz

ZH 09 24V/50-60Hz YB 09 220-230V/50-60Hz

• For the coils:

ZB 09 220-230V/50-60Hz, 240V/50-60Hz YB 09 220-230V/50-60Hz

• UL Recognized Comp. coils mark:

ZB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

YB 09 24V/60Hz, 110-120V/60Hz, 208-240V/60Hz

Series 156.2

1 2 1 2

2

1

N.C.

Normally closed Coil energised - open Coil de-energised - closed