• 검색 결과가 없습니다.

Benign Proliferative & Reactive Change

N/A
N/A
Protected

Academic year: 2022

Share "Benign Proliferative & Reactive Change"

Copied!
11
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Benign Proliferative & Reactive Change

양성 증식성 또는 반응성 변화(2)

(2)

Gardnerella vaginalis

1. Clue cell 발견

2. 중간세포의 세포질 내에 구균상의 간균 충만 3. 100% 특이성이 없음

(3)

Chlamydia trachomatis

1. 세포질 내 공포 (봉입체) 2. 달 모양의 기본 소체

(4)

Condyloma acuminatum (=Human Papillomavirus)

1. 핵의 증대 (nuclei enlargement)

2. 염색질 농염 (chromatin hyperchromasia)

3. 핵주위의 불규칙한 투명대 (irregular perinuclear halo) 4. 무핵세포 (anucleated cell)

5. 착각화세포 (parakeratotic cell)

(5)

Herpes Simplex Virus

1. 다핵성 (multinucleation)

2. 핵 밀착(연접) (nuclear molding)

3. 두꺼운 핵막 (thick nuclear membrane, chromatin margination) 4. 염색질의 젖빛유리상 (ground glass structure of chromatin)

5. 핵 내 호산성 봉입체 (intranuclear eosinophilic inclusion)

(6)

Tuberculosis

1. 림프구 관찰

2. 유상피세포 관찰

3. Langerhans’ 다핵성 거대 조직구 출현 4. 건락성 괴사

5. 석회화 물질

(7)

Cytomegalic virus (CMV)

1. 세포거대증 (cytomegalosis) 2. 두꺼운 핵막

3. 핵 내 투명대 (intra-nuclear halo)

4. 핵 내 호산성 봉입체 (intranuclear inclusion) 5. 부엉이 눈 양상 (owl eye appearance)

(8)

Senile Vaginitis ( 위축성 질염)

1. Parabasal cell (방기저 세포)

2. Red atrophy (방기저세포의 적색 위축) 3. Increase neutrophiles (호중구 증가)

4. No pathogenic organisms (병원균이 관찰되지 않음) 5. Blue blobs (점액농축 덩어리)

(9)

Chronic follicular cervicitis ( 만성 여포성 경부염)

1. 세포의 염증 변화

2. 다형의 림프구성 세포 3. 형질세포

4. 조직구

5. 괴사성 물질

(10)

Folic acid Deficiency ( 엽산 결핍)

1. 세포질과 핵이 커짐 (cytomegalosis)

2. 세포질 내 공포 (intracytoplasmic vacuole) 3. 중복염색 (polychromasia)

4. 다핵성 (multinucleation)

(11)

Radiation change ( 방사선 양성변화)

1. 세포질과 핵이 커짐 (cytomegalosis) 2. 공포 (vacuole)

3. 다핵성 (multinucleation)

4. 황색 침착물 (yellowish deposit) 형성

참조

관련 문서

Hyperoside protects cell death of Chinese hamster lung fibroblast (V79-4) cells via inhibition of apoptosis induced by H 2 O 2 as shown by.. decreased apoptotic

(B) HRCT shows the aggravation of irregular patchy airspace consolidation, multiple ground glass opacities and reticular opacities on the peripheral

(B) High resolution computed tomography scan of the chest, after 4 months, shows complete resolution of the consolidations and ground glass opacities..

HRCT findings in seven cases of Pneumocystis carinii pneumonia combined with other lung diseases included nodules(n=6), ground-glass opacity(n=5), lin- ear-reticular opacity(n=4),

In this study, we deployed glass units at a depth of 20 m below the ground surface in the groundwater-surface water mixing zone, and retrieved them after 4 months to investigate

(B) High resolution computed tomography scan of the chest, after 4 months, shows complete resolution of the consolidations and ground glass opacities.. Mild

[4] INTERNATIONAL ATOMIC ENERGY AGENCY, Ground Motion Simulation Based on Fault Rupture Modelling for Seismic Hazard Assessment in Site Evaluation for Nuclear Installations,

To fabricate metal oxide metal (OMO) structure, IGZO sputtered on a corning 1,737 glass substrate was used as bottom oxide material and then silver was evaporated on the