• 검색 결과가 없습니다.

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction: Publisher Correction

N/A
N/A
Protected

Academic year: 2022

Share "Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction: Publisher Correction"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction:

Publisher Correction

Ye Zhang and Yang Zheng**

Changchun University of Science and Technology, School of Opto-Electronic Engineering, Changchun 130022, China

*Corresponding author: [email protected] (Received January 8, 2021 : published February 25, 2021)

Keywords : Angle error correction, Geometric optics, Optical measurement, Rifling angle

OCIS codes : (080.0080) Geometric optics; (110.0110) Imaging systems; (120.4290) Nondestructive testing; (120.4640) Optical instruments

Copyright © 2021 Current Optics and Photonics

REFERENCES

1. Y. Zhang and Y. Zheng, “Research on a method for the optical measurement of the rifling angle of artillery based on angle er- ror correction,” Curr. Opt. Photon. 4, 500–508 (2020).

- 77 - Current Optics and Photonics Vol. 5, No. 1, February 2021, p. 77

DOI: https://doi.org/10.3807/COPP.2021.5.1.077

Publisher Correction

Correction to: Current Optics and Photonics (https://doi.org/10.3807/COPP.2020.4.6.500) [1]

In the original version of this Article [1], TABLE 1 presented below was not included due to an error made during production. FIG. 10, FIG. 11, and TABLE 2 were also not properly positioned. These errors were corrected in the HTML and PDF versions of the Article on 08 January 2021. © 2021 Optical Society of Korea

TABLE 1. Measurement errors of the rifling equation coefficient k

Error sources Error

symbol Error value Laser rangefinder ranging error δz 0.5 mm Barrel radius measurement error δR 0.15 mm

Angle error δθ 30″

Error in the correction of angle error δφ 30″

참조

관련 문서

Abstract : An optimization-based real-time joint angle extraction method of human elbow is proposed by processing the biomedical signal of surface EMG (electromyogram) measured at

In this study, we developed an accurate POI search method and an efficient POI alias database management method based on word embedding and similarity measurement. We classify

Study on the Correction Method of Ice Strength and Thickness Applied to the Sea Trial Condition Based on the Ice Model Test Results.. Seung-Ki Lee 1 ․ Moon-Chan Kim 1,† ․ Won-Jun

In this study, effect of the sensor gain error is theoretically analyzed and simulated when mixed sequential two-prove method(MTPM) is applied for the precision

Measured Intensity Control Method of a Phase-shift Measurement Based Laser Scanner by using APD Bias Voltage Characteristic.. 장준환 1 , 윤희선 2 , 황성의 1 ,

Numerical Method to Estimate Uncertainties Associated With Positioning Error of Stain Measurement in Drop Test of Radioactive Waste Transport Casks1. Jongmin Lim * and

Variation of sensible and latent heat fluxes symbols indicate the mean of whole measurement values/ after data screening for each month and error bars indicate the standard

Presumption Method for Optimum Correction Rate of Total Construction Cost Using the Median based on Historical Data Analysis in Public Office Buildings.. 임 진 호 1 1) 박 준 모 2*