Electron Temperature, Plasma Density and Luminous

Efficiency in accordance with Discharge Time in coplanar AC PDPs

S. H. Jeong

Charged Particle Beam and Plasma Laboratory / PDP Research Center Department of Electrophysics, Kwangwoon University, Seoul, Korea 139-701

xranbrook@naver.com, Phone : +82-2-940-5236, Fax : +82-2-913-6187

M. W. Moon, P. Y. Oh, J. M. Jeong, B. D. Ko, W. B. Park, J. H. Lee, J. E. Lim, H. J. Lee, Y. G. Han, C. G. Son, S. B. Lee, N. L. Yoo, E. H. Choi

Charged Particle Beam and Plasma Laboratory / PDP Research Center Department of Electrophysics, Kwangwoon University, Seoul, Korea 139-701

Abstract

Electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDP’s) have been experimentally investigated in accordance with discharge time by a micro-probe in this experiment. The resolution of a step mortor to move in micro-Langmuir probe is 10um.[1-3] The used gas in this experiment is He-Ne-Xe (4%) mixure gas. And sustain voltage is 320V which is above of firing voltage for degradation.

The electron temperature and plasma density can be obtained from current-voltage (I-V) characteristics of micro Langmuir probe, in which negative to positive bias voltage was applied to the probe. And Efficiency is calculated by formula related discharge power and light emission. Those experiments operated as various discharge time (0~72 Hours).

As a result of this experiment, Electron Temperature was increased from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours. The plasma density is inversely proportional to the square root of electron temperature.

So the plasma density was decreased from 1.8x1012cm-3 to 8x1011cm-3 at above discharge running time. And the Efficiency was reduced to 70% at 60hours of discharge running time.

1. Introduction

Degradation makes many influence at the length of life in AC-PDP. And it cause variation of panel’s electro-optical characteristic, image sticking, reduction of lifetime, low brightness and so on.

Consequently, it is important to compare the properties of plasmas and efficiency. In this experiment we used Micro Langmuir Probe and measure electron temperature and plasma density.

With this measurement we observed electro-optical characteristics and efficiency. The electron temperature and plasma density can be obtained from current-voltage (I-V) characteristics curve of micro Langmuir probe, in which negative to positive bias voltage was applied to the probe.[8,9]

2. Experimental Configurations

Figure 1 shows the micro Langmuir probe tip whose diameter is 20um, has been manufactured by the electro-chemical etching method.

Figure 1. Micro Langmuir probe

(2)

P-90 / S. H. Jeong

1204 • IMID ’05 DIGEST

And used 4 inch test panel has a sustaining electrode width of 300um and gap of 90um.

Figure 2. 4 inch Test Panel

The electron temperature and plasma density can be measured by[5,6]

KTe

e dV dlnΙ =

M eA KT n

Iis = i e

,where I and V are probe current and bias voltage, respectively. Te is the electron temperature, and ni is the ion (electron) density. The A is a surface area of micro Langmuir probe being taken into account the plasma sheath, M is the filling gas mass of ion, k is the Boltman constants, e is the charge of electron and Ii s

is the ion saturation current.[2-4]

The saturation plasma ion current flowed into micro Langmuir probe can be obtained by differentiating the probe voltage difference Vprobe with respect to time, which is given by[5-6]

dt t C dV

I

is probe

( )

=

and efficiency obtained by[7-9]

power e disch

AB arg η = π

A : Emission Area, B : Brightness

Driving voltage with square pulse and duty ratio of 25% has been applied to a test panel under driving frequency of 35Khz. And 320V which is above firing voltage was applied for degradation.

Figure 3. circuit of micro Langmuir probe

Figure 4. Experiment condition

3. Experimental Results

The electron temperature increased and the plasma density, sustain voltage, brightness, efficiency, discharge current decreased as the result of the experiment.

(3)

P-90 / S. H. Jeong

IMID ’05 DIGEST • 1205 Figure 5 shows us that the electron temperature

increases from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours. The plasma density is inversely proportiona l to the square root of electron temperature. So the plasma density was decreased from 1.8x1012cm-3 to 8x1011cm-3 at above discha rge running time .

-10 0 10 20 30 4 0 50 60 7 0 8 0

2 4 6

Electron Temperature ( eV ) Plasma Density

Discharged Time(Hour)

Electron Temperature(eV)

4 6 8 10 12 14 16 18 20

Ion Density ( X 10 11cm -3)

Figure 5. Plasma density and Electron Temperature

Figure 6 shows that the sustain voltage has shown to be decreased rapidly until 20hours of discharge running time and saturated beyond this time, while the brightness decreases until 40hours of discharge running time and saturates beyond this time.

-10 0 10 20 3 0 40 50 6 0 70

100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290

Sustain Voltage(V) Brightness(cd/m2)

Discharged Time (Hour)

Voltage (V)

100 150 200 250 300 350 400 450 500

Brightness (cd/m2)

Figure 6. Sustain voltage and Brightness The luminous efficiency has been shown to be reduced to 70% at 60hours of discharge running time in comparison with initial value of brightness.

-10 0 1 0 20 3 0 4 0 50 60 7 0

0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 1 1 0 1 2 0 1 3 0

Efficiency (%)

Discharged Time (Hours) Efficiency

Figure 7. Efficiency

Also it is noted in this experiment that the peak of discharge currents decreases as discharge running time increases up to 60 hours. The discharge current rising times are shown to be decreased from 1.76x10-7s to 1.2x10-7s as discharge running time increases up to 60 hours in this experiment.

-0.0000004 -0.0000002 0.0000000 0.0000002 0.0000004 0.0000006 0.0000008 -0.4

-0.3 -0.2 -0.1 0.0 0.1 0.2 0.3 0.4 0.5

Current

Time

Initial Time(0 Hour) 3 Hour

60 Hour

Figure 8. Discharge current

4. Conclusion

Electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDP’s) have been experimentally investigated in accordance with discharge time by a micro-probe in this experiment. In this experiment plasma ion density is decreased 1.8x1012cm-3 to 8x1011cm-3 at above

(4)

P-90 / S. H. Jeong

1206 • IMID ’05 DIGEST

discharge running time . And electron temperature increases from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours.

Sustain voltage decreased rapidly until 20hours of discharge running time and saturated beyond this time, while the brightness decreases until 40hours of discharge running time and saturates. The luminous efficiency has been shown to be reduced to 70% at 60hours of discharge running time in comparison with initial value of brightness. Also it is noted that the peak of discharge currents decreases from decreases as discharge running time increases up to 60 hours. The discharge current rising times are shown to be decreased from 1.76x10-7s to 1.2x10-7s as discharge running time increases up to 60 hours in this experiment

4. References

[1] J. G. Kim et. al., Int. Display Workshop 99, p. 675 (1999); J. G. Kim et. al, Korean Appl. Phys. 40, 217 (2000).

[2] S. B. Kim, et. al., Intl. Display Workshop IDW’00, P.711 (2000)

[3] G. S. Cho, E. H. Choi, Y. G. Kim, H. S. Uhm, Y. D.

Joo, J. G. Han, M. C. Kim, J.D. Kim,, J Appl. Phys.

87, 4113 (2000)

[4] G. S. Cho, E. H. Choi, J. G. Kim, Y. G. Kim, J. J.

Ko, D. I. Kim, C. W. Lee, Y. H. Seo, H. S. Uhm, Jpn. J. Appl. Phys. 38, 830 (1999)

[5] A. Wong, Introduction to Experimental Plasma Physics, (UCLA, 1998)

[6] F. F. Chen, Introduction to Plasma Physics and Controlled Fusion, (Plenum Press, 1984), p295 [7] J. C. Ahn, S. B. Kim, T. S. Cho, M. C. Choi, D. G.

Joh, M. W. Moon, Y.Seo, S. O. Kang, E. H. Choi

“Plasma Propagation Speed and Electron Temperature in Surface-Discharge in Alternating- Current Plasma Display Panels” J.J Appl. Phys Received May 9, 2001, accepted October 22,(2001)

[8] I. R. Cho, M.W. Moon, C. G. Ryu, P. R. Oh, Y.

Jung, M. C. Choi, H. S. Uhm, E. H. Choi

“Measurement of electron temperature and plasma density in coplanar AC plasma display panels”

Surface & Coating Technology 171(2003), p222- 225

[9] E. H. Choi, J. C. Ahn, M.W. Moon, ] J. G. Kim M.

C. Choi, C. G. Ryu, S. H. Choi, T. S. Cho, Y. Jung,

G. S. Cho, H. S. Uhm, “Electron temperature and Plasma Density in Surface-Discharged Alternating-Current plasma display panels” IEEE Transactions On Plasma Science. Vol. 30. NO. 6, December, p 2160-2164

참조

관련 문서

• Michael Faraday and Joseph Henry discovered that a changing magnetic field could induce a voltage in a neighboring circuit and that this voltage was proportional to the time

Before adjusting time and calendar, check the time zone of the time and calendar to set and its summer time (DST) status and adjust the setting of world time (page 12) and

In addition to the problem of this bias, the problem caused by using the time variable with a weighted wage rate may be a multicollinearity between time value (=time x

12) Maestu I, Gómez-Aldaraví L, Torregrosa MD, Camps C, Llorca C, Bosch C, Gómez J, Giner V, Oltra A, Albert A. Gemcitabine and low dose carboplatin in the treatment of

Up−Time Displayed in parenthesis, this is the length of time the process has been in the

Figure 3 displays the variation in partial pressure of CO2 recorded from the optoacoustic signal with respect to the discharge time for three different discharge currents

Triplet sub- states were found to be responsible for temperature- and time-dependent phosphorescence and the contribution of each substate in neat films was different from

As surround temperature is 23?C, operating time means that the time from supply coil rating voltage in coil of relay to closed condition of 'a' contact...