• 검색 결과가 없습니다.

Chemical ResistanceA :

N/A
N/A
Protected

Academic year: 2022

Share "Chemical ResistanceA :"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Chemical Resistance

A :No change (Rate of weight change: below 1 %; holding rate of tensile strength at break: more than 95 %; appearance: no change) B :Slight change (Rate of weight change: 1 % to 10 %; holding rate of tensile strength at break: 95 to 70 %; appearance: change)

C :Substantial change (Rate of weight change: more than 10%; holding rate of tensile strength at break: less than 70%; appearance: substantial change)

D :Dissolved

Permeability to Gases

Teonex provides gas barrier property approximately four times higher than that of PET.

Sample form: Sheet

Extension rate of extended sample : 3.5×3.5 Temperature at measurement : 30℃

Unit for permeability of O2 and CO2 : cc・100μm /㎡/ 24hr / atm Unit for permeability of water vapor : g・25μm /㎡/ 24hr

Status Kind of gas Kind of resin

Teonex PET

Extended

O2 5.9 23

CO2 24 105

Water vapor 7 21

Not extended

O2 18 53

CO2 59 263

Water vapor 15 60

Kind of chemical Teonex PET PC PBT PBN PPS PES

Inorganic chemicals

Hydrogen peroxide A A A A A A A

Concentrated sulfuric acid D D − D D − D

Nitric acid D D − D D D D

Hydrochloric acid A B − B A A B

Sodium hydroxide 10% A B B A A A A

Sodium hydroxide 30% A B C B A A A

Saturated sodium chloride solution A A A A A A A

Sodium hypochlorite A A B A A A A

Ammonia water(28%) C D D A A A A

Organic chemicals

Acetic acid A B B B A A A

Ethylenediamine C D D D A A D

Ethylene glycol A A A A A A A

Methanol A A B B A A B

Ethanol A A A A A A A

Ethyl acetate A B C B A A B

Chloroform C C D C B A D

Toluene A A C B A A A

Acetone B C C B A A D

Xylene A A C A A A A

Formic acid C C B C A A B

Oils

Gasoline A A B A A A A

Gasohol M30 A A B B A A B

Gasohol E10 A A B A A A A

Test method for chemical resistance Immersion conditions in chemical

Evaluation method for chemical resistance

Immerse JIS #3 dumbbell specimen in relevant chemical for 500 hours at normal temperature.

⑴ Change of weight: Take out the sample from the chemical, wipe any chemicals off the sample, and measure the weight.

⑵ Change of appearance: Take out the sample from the chemical, observe the appearance.

⑶ Tensile strength: Take out the sample from the chemical, adjust the humidity (23 ℃×50%), and measure the tensile strength (tensile speed: 50mm/min; distance between chucks: 30mm).

참조

관련 문서

The specimen with the girder member and design strength of 24MPa does not show change of estimated compressive strength according to thickness. Mean error between

According to the results of the dissimilar material bonding analysis and tests, in the ultra-high-tensile-strength steel and aluminum bonding, the hybrid B bonding method

Nuclear spirals that develop inside a nuclear ring can persist only when either sound speed is low or in the presence of a SMBH; they would otherwise be destroyed by the

• 대부분의 치료법은 환자의 이명 청력 및 소리의 편안함에 대한 보 고를 토대로

Modern Physics for Scientists and Engineers International Edition,

By Edward Lear • Adapted for ReadingA–Z Illustrated by

Both tensile strength and modulus increased with holding at onset temperatures of the exothermic peaks for extended duration, and with a higher heating rate up to

Tensile strength of hollow fiber membranes with different hot stretching ratio at deformation rate of 528%/min (crosshead speed:50 mm/min).. Tensile strength of hollow