• 검색 결과가 없습니다.

polysorbate 80

N/A
N/A
Protected

Academic year: 2022

Share " polysorbate 80"

Copied!
4
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

약제학회지(2009), 392

J. Kor. Pharm. Sci., Vol. 39, No. 2, 107-110 (2009)

107

Valsartan

polysorbate 80

의 혼합물의 물리화학적 성질 및 피부 손상 연구

성준호·오동훈·이동훈·조관형·우종수·용철순·최한곤 영남대학교 약학대학

(2009년 2월 18일 접수·2009년 3월 11일 수정·2009년 4월 1일 승인)

Physicochemical property and skin damage of physical mixture of valsartan and polysorbate 80

Jun-Ho Sung, Dong-Hoon Oh, Dong-Xun Li, Kwan-Hyung Cho, Jong-Soo Woo, Chul-Soon Yong and Han-Gon Choi

College of Pharmacy, Yeungnam University, 214-1, Dae-Dong, Gyeongsan 712-749, Korea

(Received February 18, 2009·Revised March, 11 2009·Accepted April 1, 2009)

ABSTRACT −To investigate the interaction and skin damage of valsartan with polysorbate 80, the physical mixture of val- sartan and polysorbate 80 was prepared and then its adhesion, dispersibility, DSC and skin damage in nude rats were inves- tigated. The physical mixture of valsartan and polysorbate 80 appeared as an aggregated form and could hardly be dispersed in water. The DSC curve showed that physical mixture disappeared the intrinsic peaks of valsartan and polysorbate 80 at about 115oC and 170oC, respectively. It appeared a new relatively broad endothermic peak at about 150oC, suggesting that valsartan was chemically interacted with polysorbate 80. Furthermore, it induced the severe skin irritation and damage in nude mice. Thus, polysorbate 80 must not be used in the preparation of valsartan-loaded pharmaceutical dosage forms.

Key words −Valsartan, Polysorbate 80, Physical mixture, Skin damage

발사탄 [Valsartan, (S)-N-valeryl-N-{[2-(1H-tertrazol-5- yl)biphenyl-4-yl-metyl}-valine] (Figure 1a) Angiotensin II

Receptor 포화적이고 가역적 억제를 통하여 혈관 수축을

억제하여 혈압을 조절하는 약물로서 다른 고혈압보다 부작 용이현저하게적어노인성고혈압에많이사용하고있다.1,2)

또한, 약물은 80%대사되지않은상태로뇨를통해

배설되며, 구조적으로 비슷한 로사르탄 (losartan)보다 Angiotensin I 억제효과가 적은반면 이뇨제 기타고혈

압에 사용되는 약물들과 상호작용이적어서 최근 병용투여

낮은용량에효율적인치료제로주목받고있다.1~5) 제품

으로는노바티스에서 DiovanR (valsartan 80 mg 함유)이라는

상품명으로심부전심혈관질환치료에도광범위하게 과가 있다고 알려져 있으며 ARB (Angiotensin Receptor Blockers)계열약물가장많이선택되는약물이다.5,6)

, 약물은 물에서의 용해도(3 ug/ml) 생체이용률

(AUC 23%)낮아 용해도 생체이용률을증가시키고자

하는연구가 많이시도되고있다.7~9)

Polysorbate (Polyoxyethylene sorbitan fatty acid esters)

(Figure 1b)계면활성제분류에속하며비이온성계면활성

논문에관한문의는주저자공동주저자에게로

Tel : 053-810-2813, E-mail : hangon@yu.ac.kr Tel : 053-810-2812, E-mail : csyong@yu.ac.kr

Figure 1−Chemical structure of valsartan (a) and Tween 80 (b).

(2)

108 성준호·오동훈·이동훈·조관형·우종수·용철순·최한곤

J. Kor. Pharm. Sci., Vol. 39, No. 2(2009)

제로써약제학 식품전처리과정, 화장품 등에서오랫동

널리사용되어왔다. 첨가제는인체에대한안정성

확보가되어 있어난용성 약물의 용해도를높이기 위해 일차적으로고려되는계면활성제이며 polysorbate 80 (폴리소

르베이트 80, Tween 80R)가장많이사용한다.10)

연구에서는발사탄의 용해도 생체이용률을증가시 키기 위한 신규고체분산체를 개발하기전에 용해보조제로 사용되는 폴리소르베이트 80발사탄의 물리적특성에

치는영향피부손상을 검토하고자하였다. 시험 방법

시약기기

발사탄은 유한약품 (안양, 대한민국)에서 제공받았으며 Tween 20, Tween 80, Span 20 Span 80 산동 DC chemical (서울, 한국)에서 구입한것을 사용하였다. 무모마

우스(Hairless mouse) 오리엔트 바이오 (서울, 한국)에서

수컷을구입하였다.

발사탄계면활성제의혼합물의제조

발사탄 1 g 페트리 접시에넣고 여기에 비이온성 계면

활성제인 Tween 20, Tween 80, Span 20 Span 80 0.3 g각각넣어 3분간교반한 증류수 0.5 g넣어

분을약간함유한 혼합물을제조하였다.11)

혼합물의물리적특성에미치는비이온성계면활성제의영향 비이온성계면활성제와발사탄과의응집성은육안으로 확인하였다. 또한, 혼합물을페트리접시에각각넣고

류수 10 mL첨가하여 24시간동안방치하여형태의변화

육안으로 관찰하여분산여부를조사하였다. DSC 측정

발사탄, Tween 80 혼합물을가지고시차주사열량계

(Differential Scanning Calorimeter, DSC 2010, TA Instruments Inc.) 이용하여 열역학적 변화를 측정하였다.

질소가스의속도조건은 20 mL/min온도는 0oC

300oC까지분당 10oC상승시키면서측정하였다.12,13)

피부손상시험

발사탄, Tween 80 혼합물 0.1 g 또는 0.1 mL 무모

마우스의피부에각각도포하고헝겊으로덮고 24시간방치

다음희생시키고정상피부 (control)비교하여 피부

손상정도를육안으로 관찰하였다.14,15)

결과 및 고찰

발사탄 계면활성제를가지고혼합한 물리적혼합물의 응집성 분포성은 Figure 2 나타내었다. Span 20

Span 80혼합물은반고형상의크림형태를나타내는반면

Tween 20 Tween 80혼합물은 단단한 고상의 형태를

나타내었다 (data not shown). 또한, Span 20 Span 80

혼합물 (a b) 물을 첨가하고 24시간 후에 관찰할

경우 서로 응집이 되지 않고 분산되었다. 반면, Tween 20 Tween 80 혼합물 (c d) 물을 첨가하고 24

후에관찰할경우분포되지않았으며서로응집이 어서덩어리로존재하였다. 이런결과들은 Tween 류가 Span

류보다 발사탄에 강력한 응집력이 있음을 나타낸다. Tween 류는 HLB 값이 15로서친수성이어서수용액상에

발사탄과 물과의 친화력을 증대시키는 반면 HLB 값이

4 Span류는상대적으로소수성이기 때문에수용액상에

발사탄과물과의친화력을감소시키는역할을하는것으 사려된다.16,17)

발사탄, Tween 80 혼합물의 DSC 자료는 Figure 3

나타내었다. 발사탄 (Figure 3b) 115oC 부근에서 예리

특정 피크를나타내고 피크는 발사탄의 융점과 관련 Figure 2−Dispersible observation of physical mixtures at 24 hr. (a) Span 20, (b) Span 80, (c) Tween 20 and (d) Tween 80.

(3)

Valsartan polysorbate 80물리혼합물의물리화학적성질 피부손상연구 109

J. Kor. Pharm. Sci., Vol. 39, No. 2(2009)

되어 있다. Tween 80 (Figure 3c) 경우에는 170oC

부근에서 넓은 특정 피크나타낸다. 그러나 혼합물 (Figure

3a) 발사탄 Tween 80 특정피크가 사라지고

150oC 부근에서 새로운 피크가 관찰되었다. 이런 혼합물에

서의물질들의고유특정피크의사라짐과새로운피크의

현한결과는발사탄이 Tween 80물리적으로반응하여

리화학적 상태가변화되었음을나타낸다.18,19)

발사탄과 Tween 80 혼합물의피부손상정도를검토하기

위하여 정상상태 (control), 발사탄, Tween 80 혼합물 dmf 무모마우스의피부에각각도포하고 24시간방치

발적 손상 정도를 관찰하였다 (Figure 4). 발사탄 (Figure 4b) Tween 80 (Figure 4c)으로단독으로 처리한

피부는정상상태의피부 (Figure 4a)비해약간의발적

손상이 발견되었으나크게 유의할만한변화를 나타내지 았다. 그러나혼합물로처리한피부의 경우 (Figure 4d)에는

수컷피부의각질층이심하게훼손되었으며피부발적이 격하게나타났다. 이런결과는발사탄 Tween 80 단독으

로는피부에 손상을 주지않으나 병용투여할 경우에는

반응하여 심각한 손상을 나타낼 있음을 보인다.14,15)

따라서, 추후에 발사탄 Tween 80 반응 정도를 X-ray

IR물리화학적성질을 검토하고병용 투여시 점막

대한점막손상정도를심도있게연구할 예정이다.

결 론

발사탄과 Tween 80혼합서로 물리적인반응을

응집이발생하고피부에심각한손상을가져오기때문에 발사탄을사용하여제제화하기위해첨가제로폴리소르베이 트류를사용할경우에 커다란주의를요한다.

감사의 말씀

논문은 2008학년도 영남대학교포항나노집적센터

구비에 의한 것이며 이에 감사를 드립니다(This work was

supported by the National Center for Nanomaterials Technology through Yeungnam University in 2008).

참고문헌

1) S. Oparil, S. Dyke, F. Harris, J. Kief, D. James, A. Hester and S. Fitzsimmons, The efficacy and safety of valsartan compared with placebo in the treatment of patients with essential hypertension, Clin Ther.,18 (5), 797–810 (1996).

2) J.L. Pool, R. Glazer, M. Weinberger, R. Alvarado, J. Huang and A. Graff, Comparison of valsartan/hydrochlorothiazide combination therapy at doses up to 320/25 mg versus monotherapy: A double-blind, placebo-controlled study followed by long-term combination therapy in hypertensive adults, Clin Ther., 29 (1), 61-73 (2007).

3) F. Waldmeier, G. Flesch, P. MuLler, T. Winkler, H.P.

Kriemler, P. Buhlmayer and M.D. Gasparo, Pharmaco- kinetics, disposition and biotransformation of [14C]- radiolabelled valsartan in healthy male volunteers after a single oral dose, Xenobiotica, 27 (1), 59–71 (1997).

Figure 4Skin damage of hairless mice. (a) control, (b) Tween 80, (c) valsartan and (d) physical mixture

Figure 3−DSC curve of (a) physical mixture, (b) valsartan and (c) Tween 80.

(4)

110 성준호·오동훈·이동훈·조관형·우종수·용철순·최한곤

J. Kor. Pharm. Sci., Vol. 39, No. 2(2009)

4) M.D. Gasparo and S. Whitebread, Binding of valsartan to mammalian angiotensin AT1 receptors, Regul. Pept., 59,

303-311 (1995).

5) Y. Mizuta, H. Kai, M. Fukui and T. Imaizumi, Long-term treatment with valsartan attenuates myocardial fibrosis and improves diastolic dysfunction in hypertensive patients The echorcardiographic assessment, J. of Cardiac Failure, 14 (7), S150 (2008).

6) L.M. Prisant, K.L. Thomas, E.F. Lewis, Z. Huang, G.S.

Francis, W. D. Weaver, M.A. Pfeffer, J.J.V. McMurray, R.M.

Califf and E.J. Velazquez, Racial analysis of patients with myocardial infarction complicated by heart failure and/or left ventricular dysfunction treated with valsartan, captopril, or both, J. Am. Coll. Cardiol., 51 (19), 1865-1871 (2008).

7) C.J. Mbah, Solubilization of valsartan by aqueous glycerol, polyethylene glycol and micellar solutions, Pharmazie., 61 (4), 322-324 (2006).

8) G.L. Amidon, H. Lennernäs, V.P. Shah and J.R. Crison, A theoretical basis for a biopharmaceutics drug classification:

the correlation of in vitro drug product dissolution and in vivo bioavailability, Pharm. Res., 12, 413-420 (1995).

9) B. Cappello, C.D. Maio, M. Iervilino and A. Miro, Improvement of solubility and stability of valsartan by hydroxypropyl-ß-cyclodextrin, J. Inclusion Phenom.

Macrocyclic Chem.,54, 289-294 (2006).

10) S. Sheetal, K.B. Anil, K.S. Rakesh, B. Tanim, M. Amarnath and M. Amarnath, Pharmacoscintigraphic Evaluation of Polysorbate 80-Coated Chitosan Nanoparticles for Brain Targeting, American J. of Drug Delivery, 3(3), 205-212 (2005).

11) W. Wasylaschuk, P. Harmon, G. Wagner, A. Harman, A.

Templeton, H. Xu and R. Reed, Evaluation of hydroperoxides in common pharmaceutical excipients, J.

Pharm. Sci., 96 (1), 106-116 (2007).

12) P.D Martino, R. Censi, C. Barthélémy, R. Gobetto, E. Joiris, A. Masic, P. Odou and S. Martelli, Characterization and compaction behaviour of nimesulide crystal forms, Int. J.

Pharm.,342 (1), 137-144 (2007).

13) B.C. Hancock and G. Zografi, Characteristics and significance of the amorphous state in pharmaceutical systems, J. Pharm. Sci., 86 (1), 1–12 (1997).

14) L. Benassi, G. Bertazzoni, C. Magnoni, M. Rinaldi, C.

Fontanesi and S. Seidenari, Decrease in toxic potential of mixed tensides maintained below the critical micelle concentration: an in vitro study, Skin Pharmacol Appl Skin Physiol., 16 (3), 156-164 (2003).

15) M. Schierholz, Physico-chemical properties of a rifampicin- releasing polydimethylsiloxane shunt, Biomaterials. 18 (8), 635-641 (1997).

16) A.N. Hassan and J.F. Frank, Influence of surfactant hydrophobicity on the detachment of Escherichia coli O157:H7 from lettuce, Int. J. Food Microbiol., 87 (1-2),

145-152 (2003).

17) L.A. Felton, T. Austin-Forbes and T.A. Moore, Influence of surfactants in aqueous-based polymeric dispersions on the thermomechanical and adhesive properties of acrylic films, Drug Dev. Ind. Pharm.,26 (2), 205-210 (2000).

18) C.F. Rawlinson, A.C. Williams, P. Timmins and I. Grimsey, Polymer-mediated disruption of drug crystallinity, Int. J.

Pharm.,336 (1), 42-48 (2007).

19) S. Zalac, M.Z. Khan, V. Gabelica, M. Tudja, E. Mestrovic and M. Romih, Paracetamol-propyphenazone interaction and formulation difficulties associated with eutectic formation in combination solid dosage forms, Chem. Pharm. Bull,,47 (3),

302-307 (1999).

참조

관련 문서

Results: LPS administration induced myocardial and perivascular fibrosis and increased cardiac oxidative stress (MDA), inflammatory markers and heart perme- ability,

External drainage and stent implantation are the methods to solve the patients with obstructive jaundice for a long time, but whether there are some difference between

On the other hand, sim- ilar to treatment with ramipril (1 mg/kg, p.o.), treatment with CA at three doses levels (20, 30 and 40 mg/kg, p.o.) significantly decreased the SBP

In this study, we assessed annexin A3 expression in 80 patients with gastric cancer and explore its correlation with prognosis Moreover, correlations with Ki-67, Bcl-2 and

Significant hepatic fibrosis [or fibrotic (F) stage ≥2 diagnosed by liver biopsy] was defined as LSM ≥7 kPa based on the result of a study of LSM using transient

Corticosteroids improves short-term survival in patients with severe alcoholic hepatitis (AH): Individual data analysis of the last three randomized

It would be necessary to establish the long term rehabilitation care facilities with extended rehabilitation program for the patients with lower functional

12) Maestu I, Gómez-Aldaraví L, Torregrosa MD, Camps C, Llorca C, Bosch C, Gómez J, Giner V, Oltra A, Albert A. Gemcitabine and low dose carboplatin in the treatment of