미용실 실내⋅외 공기오염물질 및 개인 노출 농도
송미라1)⋅손부순*⋅김한식1)⋅이진옥2)⋅나상오3)⋅양원호4)
순천향대학교 환경보건학과, 1)광주여자대학교 미용과학과, 2)한성디지털대학교 미용예술과,
3)광주송원대학 뷰티코디네이션과, 4)대구가톨릭대학교 산업보건학과 (2004년 7월 30일 접수; 2005년 1월 7일 채택)
Indoor and Outdoor Concentrations of Air Pollutants, and Personal Exposure in Beauty Shop
Mi Ra Song1)⋅Bu Soon Son*⋅Han Shik Kim1)⋅Jin Ok Lee2)⋅Sang O Na3)⋅Won Ho Yang4) Department of Environmental Health Science, Soonchunhyang University
1)Department of Beauty Science, Kwangju Women University
2)Department of Beauty Art, Han Sung Digital University, 3)Department of Kwangju Song Won College
4)Department of Occupational Health, Catholic University of Deagu (Received 30 July 2004; accepted 7 January 2005)
Abstract
The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting scalp hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals and from chemicals are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter (PM10) during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadway. Personal exposures to VOCs and PM10 were related to indoor concentrations of beauty shops, respectively. According to questionnaire, hairdressers responded sore throat, eye irritation, and nervousness as health effect symptoms. Conclusively, users as well as workers in beauty shop might be highly exposed to air pollutants from indoor sources and outdoor sources. Therefore, proper methods should be prepared to improve the indoor air quality in beauty shop.
Keywords:Beauty shop, Hairdresser, Exposure, VOCs, PM10
1. 서 론
현대 도시인들은 많은 유해 화학물질에 노출될 가능성이 높으며, 일상생활 대부분의 시간을 실내 에서 보내고 있기 때문에 실내에서의 유해 화학물 질 노출에 따른 인체에 미치는 영향은 실외환경 보다 크다고 말할 수 있다(최성우, 1996). 실내 공 기가 인간의 건강과 관련지어 대기 오염보다 더욱 중요한 이유는 인간은 하루 24시간 중에서 80%
이상을 실내(가정, 일반 사무실, 실내 작업장, 공 공건물, 지하 시설물, 상가, 음식점, 자동차, 지하 철 등)에서 생활하는 것으로 조사 보고된 바 있으 며, 실내 공기는 한정된 공간에서 인공적인 설비 를 통하여 오염된 공기가 계속적으로 순환되면서 그 농도가 증가하고 1970년대 이후 에너지 보존을 위한 새로운 건축자재의 사용증가로 인해 공공건 물 뿐 아니라 일반 주택에도 오염물질이 방출하게 되었고 냉⋅난방 연료의 사용과 에너지 절약을 위 한 실내의 밀폐 및 단열재의 사용 등으로 실내 공 기 오염이 증가되고 있는 실정이다. 실내공기오염 의 연구는 궁극적으로 인체에 미치는 영향을 파악 하는 것으로 개인의 영향을 보다 정확히 파악하기 위해서는 각 오염물질의 개인 노출량을 측정하고 개인의 신체검사, 생화학적 검사, 건강조사 등이 필요하다.
다양한 실내환경 중 미용실 실내공기오염물질 로서 자주 사용되는 화학제품에 알코올, 과황화암 모늄, 과산화수소 아미노페놀, 콜타르, 납 초산염, 메틸렌 염화물, 프로판, 포름알데히드, 클리콜에테 르, 메틸에틸케톤, 톨루엔, 자일렌, 석유 유출물 등 이 들어있다. 이 물질들은 피부조직을 파괴하고 점막, 각막, 피부 및 기도를 자극하기도 하며 각질 과 표피단백질과 반응하여 부식시키고 종류에 따
라 수포를 만들기도 하며 발적, 수종, 궤양, 반흔, 피부암을 발생시키기도 한다(김보경 등, 2001;
Ortiz et al., 2002). 미용실에서 검출 가능한 실내공 기오염 물질 중의 휘발성 유기화합물(Volatile Organic Compounds, VOCs)과 PM10은 호흡기 질환 등 각종 질병을 야기시킬 수 있다.
국민생활 수준의 향상과 발전에 따라 미(beauty) 에 대한 관심과 탐구가 늘어감에 따라 점점 증가 하는 미용인과 미용실의 실내공기오염에 관한 조 사 보고나 실내공기오염으로 인하여 발생하는 증 상 및 질환을 예방하기 위한 조사가 필요한데도 불구하고 이에 대한 연구는 미비한 실정이다(김보 경 등 2000; 장성기, 2003).
이에 본 연구는 광주 시내 미용실 20개 업소를 선정하여 실내⋅외 공기오염물질의 농도 및 개인 노출량을 측정 분석하고, 미용실에 근무하고 있는 종사자들을 대상으로 설문지를 이용하여 자각 증 상에 대한 유무를 조사하였다. 미용실을 이용하는 이용자들과 근무하고 있는 종사자들의 건강관리 와 정신적 안정, 작업능률에 도움이 되고, 미용실 의 공기질 관리에 대한 대책을 세우는데 기초자료 로 제공하고자 한다.
2. 연구 방법
2.1 연구방법
광주 시내에 위치한 미용실 20개소를 선정하여 2003년 9월 1일부터 9월 30일까지 24시간 동안 VOCs와 PM10을 측정하였다. 측정 공간은 실내, 실외, 개인(personal)의 세 부분으로 구분하였고, VOCs는 3M VOCs 측정기(3M社)를 이용하여 측 정하였다. PM10은 Cyclone(cut-off 10㎛; SKC社)을
이용하여 시료를 채취하고 분석하였다. 동시에 동 일한 미용실에서 근무하는 미용 종사자에 대한 설 문조사를 병행하였다.
2.2 측정방법 및 설문조사
측정은 광주 시내에 위치한 미용실 20곳과 미용 실에 근무하고 있는 종사자 중 1명씩 총 20명의 개인 노출을 측정하였다. 미용실 실내⋅외에서의 VOCs와 PM10 농도를 24시간 동안 측정하였다. 설 문지 내용은 각 대상 미용실 대표자 1명을 대상으 로 나이, 직책, 측정하는 미용실의 조건 조사(미용 실 건축년도, 재질, 직원 수, 환기시스템, 냉⋅난방 방법, 미용실 위치 등), 미용실 실내 환경에 대한 인식도 및 호흡기 증상 등에 대한 내용으로 작성 하도록 하였다.
2.3 측정 분석 방법
휘발성 유기화합물(VOCs)중 미용실 실내환경 및 실외 대기환경의 주요 공기오염물질인 Toluene 과 Xylene 등을 대상으로 OVM 수동식 시료채취 기(passive sampler)로 포집하였다. 측정에 이용된 OVM 수동식 시료채취기는 자연적인 기류를 이용 하여 확산(diffusion)과 침투(infiltration)라는 물리적 인 과정과 반응에 의한 화학적 반응을 이용하여 실내와 실외환경에서 VOC 농도를 측정하는 장치 이다. 일반적으로 3M OVM 수동식 시료채취기의 측정시간은 8시간을 기준으로 하고 있으나, 포집 용량이 허용되는 경우 24시간 내지 72시간까지도 측정이 가능하다. 이에 본 연구는 1일 24시간의 노출을 기준으로 측정하였다. 분석은 일반 활성탄 관법의 분석과 마찬가지로 각 샘플을 2mL CS2로 탈착하여 GC/MS(가스크로마토그래피 질량분석 기)를 이용하여 분석하였다. GC/MS 분석 조건은
초기 온도 31℃에서 2분간 머물도록 하였으며, 100℃까지 분당 5℃씩 승온시키고 1분간 머물도 록 하였으며, 다시 200℃까지 분당 50℃씩 승온시 켜 1분간 머물도록 하였다. 분석하고자 하는 10가 지의 대상물질 대부분이 위의 조건에서 분리되어 나왔다. 3M OVM 뱃지를 이용한 VOCs의 농도는 측정시간, GC/MS로 정량된 물질의 양(㎍), 그리고 계산 상수를 이용하여 계산하였다. 탈착효율은 3M OVM 뱃지의 분석가이드에서 제시한 값을 이 용하였다(Fellen and Otson, 1994).
PM10 먼지 농도는 채취된 시료여지를 채취전과 동일한 방법으로 항온, 항습 상태인 데시케이터 내에서 48시간 이상 방치한 후 0.01㎍까지 측정 가능한 Semi-micro balance(Sartorious社, BP21D)를 사용하여 여지 무게를 측정한 후 질량농도를 분석 하였다.
실내환경의 시료는 미용실 최대한 중앙에서 측 정하였으며, 실외 대기환경의 시료는 주로 건물 외벽에 고정시켜서 채취하였으며, 지상 1.5m 이상 으로 설치하였고, 건물 환기구나 연돌과 같은 국 지적 배출원의 영향을 직접적으로 받지 않는 지점 을 선정하였다. 미용사 개인노출은 호흡구 (breathing zone) 근처에 부착하도록 하였다.
3. 결과 및 고찰
3.1 조사 대상자 및 미용실 환경특성
조사대상자의 성별은 여자가 85%이고 연령은 30대가 55%, 40대가 25%, 20대가 3%, 50대가 5%
이었고, 근무연수(경력)는 4∼9년이 가장 많고 20 년 이상의 경력자가 20%였고 직책은 원장이 95%
로 나타났다(Table 1).
미용실 환경특성으로 면적이 10평 이하가 60%
로 가장 많았으며 미용실 위치는 도로변이 95%이 고 건축년도는 3년 이하가 25%, 10년 이하가 10%, 20년 이하가 60%, 30년 이하가 5%로 다양하였다 (Table 2). 미용실 내부의 바닥재질은 페인트가 65%였고 벽 재질은 페인트가 35%이며 천정 재질 은 페인트가 25%였다. 천정에 페인트 또는 벽지 를 바른 때는 2년 전이 55%, 벽에 페인트 또는 벽 지를 바른 때는 2년 전이 55%, 바닥 교체 시기는 2년 전이 45%였다. 환기 시설은 주로 환풍기와 출 입문 개폐이며 난방방법은 주로 석유난로가 가장 많고 그 밖에 전기 팬히터, 전기난로를 사용하고 있었다. 따라서 미용실 면적이 적을수록 주변여건 이 도로변에 위치할수록 실내로 유입되는 대기오 염물질과 환기부족 등으로 미용사의 건강에 영향 을 줄 수 있는 것으로 생각할 수 있다(Table 2).
3.2 실내공기질 인식도 및 미용사들의 자각증상 실내환경 인식도는 출근 즉시 미용실 환기를 하
는 곳이 95%이고 실내공기오염이 인체에 미치는 영향이 있는지에 관한 질문에는 85%가 '예'라고 대답하였으며 실내의 먼지가 많다고 생각하는지 가 80%, perm제, 염모제, bleach제의 약품 냄새가 난다고 생각하는 사람이 80%를 차지하였다. 그리 고 미용실의 실내공기가 가정의 실내공기보다 더 좋은지의 비교는 '아니오'가 100%로 나타나 미용 실 내 공기가 좋지 않음을 인식하고 있는 것으로 알 수 있다. 미용실에서 자각하는 증세로는 목이 아픈 경우, 눈이 아프고 침침한 경우, 신경이 예민 해지는 경우가 각각 70%로 나타났고 전신이 노곤 한 경우 65%였다. 이러한 결과는 미용실에서 화 학약품을 사용함으로써 일어날 수 있는 증세이며 perm 용액이나 bleach제, 염모제, hair spray 등의 자극적인 냄새와 분진으로 인하여 미용종사자들 에게 눈, 코, 목, 폐에 염증을 일으켜 눈이 아프고 침침하여 재채기나 감기, 호흡기 질환을 유발시킬 가능성이 크다고 생각한다(Table 3).
Table 1. General characterization of participants in this study.
Number (%)
Sex Male
Female
3 (15.0) 17 (85.0)
Age (year)
20 30 40 50
3 (15.0) 11 (55.0) 5 (25.0) 1 (5.0)
Work experience (year)
< 4 4 ∼ 9 10 ∼ 15 16 ∼ 20 > 20
2 (10.0) 8 (40.0) 3 (15.0) 3 (15.0) 4 (20.0)
Table 2. Characterization of beauty shop in this study.
Variable Number (%)
Floor area under 33 ㎡ under 49.5 ㎡
under 66 ㎡
12 (60.0) 6 (30.0) 2 (10.0)
Construction year
under 3 years under 10 years under 20 years under 30 years
5 (25.0) 2 (10.0) 12 (60.0) 1 (5.0) Location Residential area
Near a street 1 (5.0) 19 (95.0) Tye of floor tile
painted 7 (35.0)
13 (65.0)
Type of wall
concretewood painted
paper others
3 (15.0) 2 (10.0) 7 (35.0) 5 (25.0) 3 (15.0)
Floor exchange
1 year ago 2 years ago 3 years ago 4 years ago 5 years ago
3 (15.0) 9 (45.0) 3 (15.0) 4 (28.0) 1 (5.0)
Table 3. Subjective symptoms of participants in beauty shop.
Yes (number, %) No (number, %) Headache
Tiredness Feel heavy in the chest
Sore throat Yawning Face febricity Eye irritation
Dizziness
Tremor of the hands and foots Eyelid convulsions
Nervousness Sneezing
ColdFlu Sputum
8 (40.0) 13 (65.0) 9 (45.0) 14 (70.0) 12 (60.0) 9 (45.0) 14 (70.0) 6 (30.0) 5 (25.0) 7 (35.0) 14 (70.0) 9 (45.0) 6 (30.0) 7 (35.0) 4 (20.0)
12 (60.0) 7 (35.0) 11 (55.0) 6 (30.0) 8 (40.0) 11 (55.0) 6 (30.0) 14 (70.0) 15 (75.0) 13 (65.0) 6 (30.0) 11 (55.0) 14 (70.0) 13 (65.0) 16 (80.0)
3.3 VOCs의 실내⋅외 및 개인노출
여러 가지 종류의 VOCs 물질이 미용실에서 검 출되었으나 그 중 Toluene과 Xylene의 농도가 모 든 미장원에서 검출되어 농도 비교와 상관성 분석 의 대상으로 사용하였다. 미용실의 위치가 상업적 인 측면에서 비교적 도로변 근처이고, 계절상 미 용실 창 또는 문이 주로 닫혀 있는 것을 고려하면 Toluene의 경우 차량에 의한 실외오염원, 미용실 에서 사용하는 네일 에나멜의 성분 중 22.3%, 베 이스 코트(base coat)에 23.0%, 탑 코트(top coat)에 28.5%가 함유되어 있으므로 실내오염원을 모두 가지고 있는 것으로 생각할 수 있다. Acetone뿐만 아니라 검출된 다른 VOCs 물질들은 미용실의 환 경과 여건에 따라 편차가 크고 불검출이 높게 나 타나 비교 분석 대상으로 사용하지 않았다.
Xylene의 실내오염원은 내부 벽 재질에 따라 페인 트, 락카 등의 건축자재로 이것들은 새로 지은 건 물일수록 실내공기를 오염시키며, 미용실에서 네 일 에나멜을 지우는데 쓰이는 Acetone은 에나멜 리무버의 주성분으로서 70% 정도 함유되어 주로 자극적인 냄새와 피부자극을 유발시킨다. Xylene 의 농도는 실외, 개인노출보다 실내 쪽이 가장 큰 것으로 나타났다(Table 4).
VOCs 중 Toluene과 Xylene의 상관성 분석결과 를 Table 5에 나타내었다. Toluene의 실내, 실외, 개인노출에 대한 상관성 분석을 한 결과 실외와 실내는 0.087로 유의성을 나타내지 않았으며, 개 인 노출과 실내는 0.535, 개인노출과 실외는 0.322 로 통계적으로 유의한 상관성을 보였다. Xylene도 실외와 실내는 0.358로 통계적으로 유의한 관련이
Table 4. Measured VOCs concentrations in beauty shops.
(unit:㎍/㎥) Indoor
concentration (Mean±S.D)
Outdoor concentration
(Mean±S.D)
I/O ratio (Mean±S.D)
Personal exposure (Mean±S.D) n-Octane
Acetone Ethyl acetate
Benzene Ammonia
MIBK2) Perchloroethylene
Toluene Buthyl acetate Ethyl benzene
Xylene Styrene 1,2,4-Trimethylbenzene
1,2-Dichlorobenzene
N.D.1) 31.7±65.1
0.8±3.5 0.2±0.7 1.3±3.5 0.5±2.4 5.2±23.0
9.8±5.8 3.1±7.7 0.6±1.8 30.3±20.3
1.1±3.8 N.D.
N.D.
N.D.
0.4±1.8 1.5±6.7 0.1±0.2 0.8±1.7 1.0±3.1 1.5±6.7 10.2±9.4
0.9±4.0 0.8±2.0 22.1±18.2
0.3±1.5 N.D.
N.D.
0.96±0.08
1.37±3.4
N.D.
42.1±75.2 1.8±4.3 0.01±0.4 10.2±9.4 0.8±2.6 4.5±20.1 11.2±6.2 2.2±6.9 1.7±2.4 25.6±21.2
1.3±3.4 0.3±1.4 1.9±8.3
1) N.D. : Not Detected
2) MIBK : Mentyl Isobutyl Ketone
있었으며, 개인노출 농도와 실내농도는 0.452로 유의한 상관을 나타내어 개인노출에 미용실 실내 공기가 영향을 주고 있음을 알 수 있다(Table 5).
3.4 PM10의 실내⋅외 및 개인노출
PM10의 실내, 실외 및 개인 노출의 평균과 표준 편차는 미용실 실내농도가 30.5±25.8㎍/㎥, 실외농 도는 31.0±53.6㎍/㎥이고, 개인 노출 농도는 38.6
±34.1㎍/㎥이었다. 본 결과에서 보듯이 미용실의 PM10 농도는 실내, 실외보다 개인 노출 농도 쪽이 가장 큰 것으로 나타났다. 이 결과는 미용실의 위 치가 주로 도로변임을 고려할 때, 미용실의 머리 카락을 예상하여 고농도를 예측하였으나 비교적 저농도를 나타내어 미용실에서 발생되는 머리카 락 등 분진의 입경이 10㎛보다 큰 것으로 생각할
수 있다. 또한 미용사들의 PM10 노출은 미용실 실 내보다 다른 실내⋅외의 환경에 영향을 받을 가능 성이 있는 것으로 생각할 수 있다(Table 6).
PM10의 Pearson 상관성 분석 결과를 Table 8에 나 타내었다. PM10의 실내, 실외, 개인노출에 대한 상 관성 분석을 한 결과 실외와 실내는 r=0.022로 통 계적으로 유의하지 않은 것으로 나타났으며, 개인 노출과 실내에 대한 통계분석결과 r=0.070으로 유 의성을 나타내지 않았다. 그러나 개인노출과 실외 PM10 농도는 r=0.416으로 통계적으로 유의한 결과 를 나타냈다. 이번조사의 대상이 된 미용실이 주로 도로변에 위치하고 있었던 점을 고려하면, 이는 미 용실의 위치 선정도 미용사들의 건강에 중요한 영 향을 주는 인자로 관리되어야 한다는 것을 본 논문 결과는 제시하고 있는 것으로 판단한다(Table 7).
Table 5. Correlation among indoor, outdoor, and personal exposure for VOCs.
Indoor Outdoor Personal exposure
Toluene
Indoor Outdoor Personal
1.000 0.087 0.535
1.000
0.322 1.000
Xylene
Indoor Outdoor Personal
1.000 0.358 0.452
1.000
0.123 1.000
Table 6. Indoor and outdoor PM10 concentration of beauty shop, and personal exposure.
Mean±S.D Indoor
Outdoor Indoor/outdoor (I/O)
Personal exposure
30.5±25.8 ㎍/㎥
31.0±53.6 ㎍/㎥
0.98±0.11㎍/㎥
38.6±34.1 ㎍/㎥
4. 요 약
본 연구는 광주광역시에 소재한 미용실 20개소 를 선정하여 미용실에 근무하고 있는 종사자 중 1 명씩 총 20명의 대상자들에게 실내 환경의 특성과 농도와의 관계를 파악하기 위해 설문조사, VOCs 와 PM10을 2003년 9월 1일부터 9월 30일까지 24시 간 동안 측정하였다.
대상자의 일반적 특성, 미용실 실내환경에 관한 인식상황, 미용실 실내환경에 관한 사항, 미용실 내⋅실외⋅개인노출에 대한 VOCs의 농도와 PM10
의 농도와의 상관성을 비교 분석하였다. 미용실 실내공기질에 대한 종업원의 인식은 매 우 높았으며, 설문지를 이용한 간접 건강영향으로 피곤함, 목과 눈의 아픔 등을 나타내었다. 김보경 (2000)의 선행연구에서 종업원의 증상호소율은 목 이 아프다(50.0%), 머리가 아프다(46.7%)의 순으로 나타났는데, 본 연구에서는 목이 아픈 경우(70%), 머리가 아픈 경우(40%), 눈이 아프고 침침한 경우 (70%), 전신이 노곤한 경우(65%)가 좀 더 높게 나 타났다. 그 원인으로 미용실 실내환경 내 사용하 는 각종 화학물질과 미용실의 도로변 위치가 주된 것으로 생각할 수 있었다. 주된 측정 대상 항목인 PM10과 VOCs 중 Toluene과 Xylene는 미용실 실내 공기가 미용사 개인노출에 주요 요인인 것으로 나
타나 미용사뿐만 아니라 미용실 이용자에 대한 유 해 공기오염물질의 노출방지 대책이 시급한 것으 로 판단하였다.
이번 연구결과는 유기화합물(VOCs)의 경우는 개인노출농도로 실내, 실외농도의 영향을 받고 있 었으며, 기존 연구결과와 일치하고 있다(손부순 등, 2003). 이는 미용실에서 근무하는 종사자의 경 우 VOCs 노출로부터의 영향을 줄이기 위해 실내 환경에 대한 보다 많은 연구와 대책이 필요하다는 것을 제시하는 것으로 생각된다.
본 연구는 미용실을 대상으로 한 국내 최초의 VOCs 농도 측정결과라는 점에 의의가 있으며, 앞 으로 미용실을 대상으로 한 유기화합물의 연구에 기초자료로 활용될 것으로 사료된다.
참고문헌
김보경, 문덕한, 배동진 (2000) 부산 지역 미용실 의 공기오염도에 관한 연구, 한국미용학회지, 7(1), 65-72.
김보경, 조미영, 문덕한 (2001) 부산지역 미용실의 중금속 오염도에 관한 연구, 한국미용학회지,
6(2), 335-343.
장성기 (2003) 실내공기질 공정시험방법 작성 방 Table 7. Correlation among indoor, outdoor, and personal exposure for PM10.
Indoor Outdoor Personal exposure Indoor
Outdoor Personal exposure
1.000 0.022 0.070
1.000
0.416* 1.000
*p < 0.05
향, 대한주택공사 주택도시연구원, 2003년 겨울 호, 59-69.
최성우 (1996) 실내공기질 : 실내오염원 및 실내오 염 제어방법의 고찰, 환경과학논집, 1(1), 113-134.
Bae, H., Yang, W., and Chung, M. (2004) Potential exposure and traffic contribution to indoor air quality of shoe-stalls near busy road in Korea, The Science of the Total Environment, 323, 99-105.
Edwards, R.D., Jurvelin, J., Saarela, K., and Jantunen, M. (2001) VOC concentrations measured in personal samples and residential indoor, outdoor and workplace microenvironments in EXPOLIS-Helsinki, Finland, Atmospheric Environment, 35, 4531-4535.
Fellin, P. and Otson, R. (1994) Assessment of the influence of climatic factors on concentration levels of volatile organic compounds(VOCs) in Canadian homes, Atmospheric Environment, 28
(22), 3581-3586.
Jo, W. and Song, K. (2001) Exposure to volatile organic compounds for individuals with occupations associated with potential exposure to motor vehicle exhaust and/or gasoline vapor emissions, The Science of the Total Environment, 269, 25-37.
Jones, A.P. (1999) Indoor air quality and health, Atmospheric Environment, 33, 4535-4564.
Ortiz, E., Alemon, E., Romero, D., Arriaga, J.L., Olaya, P., Guzman, F., and Rios, C. (2002) Personal exposure to benzene, toluene and xylene in different microenvironments at the Mexico city metropolitan zone, The Science of the Total Environment, 287, 241-248.
3M Organic Vapor Monitor #3500 Analysis Guide, Occupational Health and Safety Products Division/3M (http:\www.3m.com).