• 검색 결과가 없습니다.

Assessment of Seasonal Variations in the Treatment Efficiency of Constructed Wetlands

N/A
N/A
Protected

Academic year: 2021

Share "Assessment of Seasonal Variations in the Treatment Efficiency of Constructed Wetlands"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Assessment of Seasonal Variations in the Treatment Efficiency of

Constructed Wetlands

Nash Jett DG. Reyes

*

, Franz Kevin F. Geronimo

**

, Hyeseon Choi

***

, Minsu

Jeon

****

, Lee-Hyung Kim

*****

...

Abstract

Unlike conventional treatment technologies, the performance of nature-based facilities were susceptible to seasonal changes and climatological variabilities. This study evaluated the effects of seasonal variables on the treatment performance of constructed wetlands (CWs). Two CWs treating runoff and discharge from agricultural and livestock areas were monitored to determine the efficiency of the systems in reducing particulates, organics, and nutrients in the influent. For all four seasons, the mean effluent suspended solids concentration in the agricultural CW (ACW) increased by –2% to –39%. The occurrence of algal blooms in the system during summer and fall seasons resulted to the greatest increase in the amount of suspended materials in the overlying water. unlike ACW, the livestock CW (LCW) performed efficiently throughout the year, with mean suspended solids removal amounting to 61% to 68%. Algal blooms were still present in LCW seasonally; however, the constant inflow in the system limited the proliferation of phytoplankton through continuous flushing. The total nitrogen (TN) and total phosphorus (TP) removal efficiencies in ACW were higher during the summer (21% to 25%) and fall (8% to 21%) seasons since phytoplankton utilize nitrogen and phosphorus during the early stages of phytoplankton blooms. In the case of LCW, the most efficient reduction in TN (24%) and TP (54%) concentrations were also noted in summer, which can be attributed to the favorable environmental conditions for microbial activities. The mean removal of organics in ACW was lowest during summer season (-52% to 35%), wherein the onset of algal decay triggered a relative increase in organic matter and stimulate bacterial growth. The removal of organics in LCW was highest (54 % to 55%) during the fall and winter seasons since low water temperatures may limit the persistence of various algal species. Variations in environmental conditions due to seasonal changes can greatly affect the performance of CW systems. This study effectively established the contributory factors affecting the feasibility of utilizing CW systems for treating agricultural and livestock discharges and runoff.

Keywords : Constructed wetland, Low impact development, Nature-based solutions

* PhD Student, Civil and Environmental Engineering Dept., Kongju National University⋅E-mail : [email protected] ** PhD Candidate, Civil and Environmental Engineering Dept., Kongju National University⋅E-mail : [email protected] ***PhD Candidate, Civil and Environmental Engineering Dept., Kongju National University⋅E-mail : [email protected] **** PhD Student, Civil and Environmental Engineering Dept., Kongju National University⋅E-mail : [email protected] ***** Professor, Civil and Environmental Engineering Dept., Kongju National University⋅E-mail : [email protected]

2020 한국수자원학회 학술발표회

참조

관련 문서

그러므로 어떤 관심사에 대해 탐구하고 문제를 해결한 경험 중에 서 몰입하거나 집중하여 탐구한 것, 끈질기게 파고들어 탐구한 내용, 친구들과 함께

Department of Naval Architecture and Ocean Engineering, Seoul National University of College

– Directly support earth until the shotcrete reach the required bearing capacity, distribute loads to shotcrete, and shape the tunnel cross section.

Department of Naval Architecture and Ocean Engineering, Seoul National University of College

Department of Naval Architecture and Ocean Engineering, Seoul National University of College

Department of Civil and Environmental Engineering, Urban Design Major...

457.657 Civil and Environmental Project Management Department of Civil and Environmental Engineering..

• Bridge Types Depending on Deck Types: Cable Stayed Bridge (사장교). – The cables are attached to the towers, which alone