stent fracture

Top PDF stent fracture:

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation

... LL stent, Abbott, Cashel Road Clonmel Tipperany, EPC;Endothelial Progenitor Cell Capture stent, OrbusNeich, Fort Lauderdale, FL, ZES; Zotalimus Endeavor stent, Medtronic, Minneapolis, Minnesota) 로 ...

8

Intravascular Ultrasound-Guided Treatment for In-stent Restenosis Associated with Stent Fracture in Overlapped Drug-eluting Stents

Intravascular Ultrasound-Guided Treatment for In-stent Restenosis Associated with Stent Fracture in Overlapped Drug-eluting Stents

... with Stent Fracture in Overlapped Drug-eluting Stents Min Chul Kim, Myung Ho Jeong*, Doo Sun Sim, Young Joon Hong, Ju Han Kim, and Youngkeun Ahn Division of Cardiology, Department of Internal Medicine, ...

3

A Sirolimus: Eluting Stent Fracture Combined with a Coronary Artery Aneurysm.

A Sirolimus: Eluting Stent Fracture Combined with a Coronary Artery Aneurysm.

... a stent thrombosis remain in this era of using DES. Re- cently, stent fractures and coronary artery aneurysms after the implantation of a drug-eluting stent have emerged as novel complications as ...

3

Clinical Characteristics of Coronary Drug-Eluting Stent Fracture: Insights from a Two-Center DES Registry

Clinical Characteristics of Coronary Drug-Eluting Stent Fracture: Insights from a Two-Center DES Registry

... to stent fracture, and is also consistent with our data, as ...the stent frac- ture cases occurred in the RCA. Although stent fracture was associated with an increased risk for TLR, ...

6

A Case of a Zotarolimus-Eluting Stent Fracture in the Left Anterior Descending Artery in a Patient Undergoing Hemodialysis

A Case of a Zotarolimus-Eluting Stent Fracture in the Left Anterior Descending Artery in a Patient Undergoing Hemodialysis

... Although stent fracture after implantation of a drug-eluting stent (DES) is a rare com- plication, it has been suggested to be a cause of ...olimus-eluting stent fracture after 8 months ...

3

Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Protégé GPS Stent

Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Protégé GPS Stent

... 고 찰 천대퇴동맥은 가장 긴 말초 동맥으로 주변 근육 및 관절의 움 직임에 의하여 다양한 힘을 받게 되며 이에 의하여 재협착이 빈 번히 발생하고, 골절 또한 잘 발생할 것으로 생각한다. Siroli- mus Coated Cordis Self-expandable Stent (SIROCCO) trial (9)에서 스텐트 골절이 발생할 수 있음을 처음으로 보고 하였고 이후 이에 관한 ...

6

Stent Fracture after Modified Gianturco Stent Placement in Patients with Malignant Esophageal Stricture: A Case Report

Stent Fracture after Modified Gianturco Stent Placement in Patients with Malignant Esophageal Stricture: A Case Report

... A silicone-covered modified Gianturco stent in patients with malignant esophageal stricture is an easy , safe , and effective palliative procedure , but reports of c[r] ...
Very Late Stent Thrombosis Related to Fracture of a Sirolimus-Eluting Stent

Very Late Stent Thrombosis Related to Fracture of a Sirolimus-Eluting Stent

... the stent fracture may have existed prior to that ...the fracture site, might have induced atherosclerotic plaque growth and ...the fracture site after the follow-up angiogram was ...the ...

3

Drug-Eluting Stent Strut Fracture as a Cause of Restenosis

Drug-Eluting Stent Strut Fracture as a Cause of Restenosis

... the fracture of a sirolimus-eluting stent, which was confirmed by intravascular ...a stent fracture is an important cause of restenosis in this era of drug-eluting ...

3

A Case of Stent Strut Fracture of a Paclitaxel-Eluting Stent at the Time of Stent Implantation in a Complex Coronary Lesion

A Case of Stent Strut Fracture of a Paclitaxel-Eluting Stent at the Time of Stent Implantation in a Complex Coronary Lesion

... WORDS: Stent, fracture; Drug-eluting ...drug-eluting stent (DES) has led to a marked reduction in the restenosis ...multiple stent use and small-vessel disease. 1) Stent strut fractures ...

3

Extensive Late-Acquired Incomplete Stent Apposition After Sirolimus-Eluting Stent Implantation

Extensive Late-Acquired Incomplete Stent Apposition After Sirolimus-Eluting Stent Implantation

... The length of ISA in LAD and RCA was 34.2 mm and 26.2 mm respectively. Furthermore, focal stent fracture also existed within the stent body in RCA. The stent strut-free length was 1.42 mm. The ...

4

Current Management of In-Stent Restenosis

Current Management of In-Stent Restenosis

... CHARACTERIZAION AND PRESENTATION OF ISR Mounting evidence strongly suggests that there are significant differences between ISR in BMS and DES, 10)11) with the main disparities, time of presentation, morphological ...

13

Stent Graft

Stent Graft

... 협진에서 수술 전, 후 급성 뇌졸중 상태임을 고려하고, 수 술 중 수축기 혈압을 가급적 120 mmHg 이상으로 유지하 도록 권고받았다. 이 환자는 상행대동맥과 하행흉부대동맥에 각각 분리 된 대동맥류가 존재하였는데, 수술 전에 수술 계획을 계 획을 세우는 단계에서 두 병변에 대해 동시에 수술적 교 정을 시행할 경우 수술과 관련된 합병증의 위험이 높다는 점, 단계적으로 수술적 교정을 시행하는 ...

4

Traumatic Subclavian Artery Dissection in Clavicle Fracture Due to Blunt Injury: Surgery or Stent in Long Segment Occlusion?

Traumatic Subclavian Artery Dissection in Clavicle Fracture Due to Blunt Injury: Surgery or Stent in Long Segment Occlusion?

... Soon-Ho Chon, M.D., Ph.D, Kilsoo Yie, M.D., Jae Gul Kang, M.D. Department of Thoracic and Cardiovascular Surgery, Cheju Halla Hospital, Jeju, S. Korea Subclavian injuries in blunt trauma are reported in less than 1% of ...

3

Intravascular Stent Graft with Polyurethane and Metallic Stent: Experimental Study

Intravascular Stent Graft with Polyurethane and Metallic Stent: Experimental Study

... Lateral maximum intensity projection of spiral CT angiography after 2months follow-up shows 20 % stenosis of the aorta by thrombus (arrows) in the stent graft.. Maximum [r] ...
Stent Thrombosis in the Era of the Drug-Eluting Stent

Stent Thrombosis in the Era of the Drug-Eluting Stent

... as stent material, design, surface coating, and adjunctive therapeutic agents, such as radiation or drugs, were suggested as risk ...total stent length and the use of multiple stents per lesion may be ...

4

Coronary Stent Thrombosis: Current Insights into New Drug-Eluting Stent Designs

Coronary Stent Thrombosis: Current Insights into New Drug-Eluting Stent Designs

... after stent implantation leads to the pro- liferation and migration of vascular smooth muscle cells through the cell cycle pathway, which results in the devel- opment of neointimal hyperplasia and in-stent ...

9

Clinical Outcomes After Multiple Self-Expandable Metallic Stent Placement Using Stent-In-Stent Technique for Malignant Gastric Outlet Obstruction

Clinical Outcomes After Multiple Self-Expandable Metallic Stent Placement Using Stent-In-Stent Technique for Malignant Gastric Outlet Obstruction

... 2. Materials and methods 2.1. Patient population Between July 2006 and July 2018, 170 patients with gastric outlet obstruction (GOO) underwent gastroduodenal SEMS placement using a stent-in-stent technique. ...

7

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent

... 약물용출 스텐트 도입은 경피적 관상동맥 중재 술 [4-5] 후 표적 병변 재 시술(TLR; Target Lesion Revascularization:)의 속도를 줄이는 중요한 단계라 고 볼 수 있다. 특히 심혈관 질환 위험이 높은 환자 와 복잡한 병변으로의 경피적 관상동맥 중재술 확 장으로 인한 재협착률은 발생빈도가 여전히 환자 의 20%에 영향을 미치고 있다. [6-9] 약물용출 스텐트 는 ...

9

Percutaneous ureteral stent insertion

Percutaneous ureteral stent insertion

... We performed 31 cases of p ercutaneous double pig tail ureteral stent insertion in 21 pa- tients , included 13 patients with malignant ureteral obstruction and eight[r] ...

Show all 2028 documents...