• 검색 결과가 없습니다.

intravascular ultrasound

Optimization of Stent Deployment by Intravascular Ultrasound

Optimization of Stent Deployment by Intravascular Ultrasound

... Korea Intravascular ultrasound (IVUS) is a useful diagnostic method that provides valuable information in addition to angiog- raphy regarding the coronary vessel lumen, dimensions, plaque burden, and ...

9

Intravascular ultrasound findings of coronary wall morphology in a child with Kawasaki disease

Intravascular ultrasound findings of coronary wall morphology in a child with Kawasaki disease

... Intravascular ultrasound (IVUS) imaging was performed to assess the coronary wall morphology in detail at 22 months after the onset of Kawasaki disease in a girl who had developed coronary aneurysms at 4 yr ...

3

Comparison of Sirolimus and Paclitaxel-Eluting Stents for Complex Coronary Lesions: An Intravascular Ultrasound Study

Comparison of Sirolimus and Paclitaxel-Eluting Stents for Complex Coronary Lesions: An Intravascular Ultrasound Study

... 10. Ako J, Morino Y, Honda Y, et al. Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis. J Am Coll Cardiol 2005;46:1002-1005. 11. Dawkins ...

7

Intravascular Ultrasound-Guided Troubleshooting in a Large Hematoma Treated With Fenestration Using a Cutting Balloon

Intravascular Ultrasound-Guided Troubleshooting in a Large Hematoma Treated With Fenestration Using a Cutting Balloon

... Intravascular Ultrasound-Guided Troubleshooting in a Large Hematoma Treated With Fenestration Using a Cutting Balloon Hye Jin Noh, MD, Jin-Ho Choi, MD, Young Bin Song, MD, Hyun Chul Jo, MD, Ji Hyun Yang, ...

4

Usefulness of multidetector computed tomography for the evaluation of coronary vascular lesions assessed by intravascular ultrasound

Usefulness of multidetector computed tomography for the evaluation of coronary vascular lesions assessed by intravascular ultrasound

... status of coronary disease, it does not accurately determine the likelihood of acute coronary syndrome. 5,6,7 Conventional coronary angiography provides excellent data on luminal size; however, it is limited to the ...

39

Intravascular Ultrasound-Guided Treatment for In-stent Restenosis Associated with Stent Fracture in Overlapped Drug-eluting Stents

Intravascular Ultrasound-Guided Treatment for In-stent Restenosis Associated with Stent Fracture in Overlapped Drug-eluting Stents

... Intravascular Ultrasound-Guided Treatment for In-stent Restenosis Associated with Stent Fracture in Overlapped Drug-eluting Stents Min Chul Kim, Myung Ho Jeong*, Doo Sun Sim, Young Joon Hong, Ju Han Kim, ...

3

Hypercholesterolemia and Coronary Plaque Composition in Patients with Coronary Artery Disease: A Virtual Histology - Intravascular Ultrasound Study

Hypercholesterolemia and Coronary Plaque Composition in Patients with Coronary Artery Disease: A Virtual Histology - Intravascular Ultrasound Study

... A recent study showed that diabetes mellitus, 18) ACS, 19-22) and po- sitive remodeling 23) is related with a high percentage of necrotic vol- ume. Also, it is well known that hypercholesterolemia is one of the major ...

6

Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound

Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound

... licenses/by-nc/3.0) which permits unrestricted non- commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Purpose: Accurate evaluation of side branch (SB) ostium ...

5

Outcomes of Percutaneous Coronary Intervention in Intermediate Coronary Artery Disease Fractional Flow Reserve–Guided Versus Intravascular Ultrasound–Guided

Outcomes of Percutaneous Coronary Intervention in Intermediate Coronary Artery Disease Fractional Flow Reserve–Guided Versus Intravascular Ultrasound–Guided

... Intravascular ultrasound guid- ance was performed using con- ventional 6- or 7-F guiding cath- eters and a 0.014-mm guidewire positioned distally, and IVUS catheters of 30 or 40 MHz (Bos- ton Scientific ...

6

Atherosclerotic Progression Attenuates the Expression of Nogo-B inAutopsied Coronary Artery: Pathology and Virtual Histology Intravascular Ultrasound Analysis

Atherosclerotic Progression Attenuates the Expression of Nogo-B inAutopsied Coronary Artery: Pathology and Virtual Histology Intravascular Ultrasound Analysis

... 17. Nair A, Kuban BD, Tuzcu EM, Schoenhagen P, Nissen SE, Vince DG. Coronary plaque classification with intravascular ultrasound radiofrequency data analysis. Circulation 2002; 106: 2200-6. 18. Dodd DA, ...

9

Relationship between Coronary Artery Calcium Score by Multidetector Computed Tomography and Plaque Components by Virtual Histology Intravascular Ultrasound

Relationship between Coronary Artery Calcium Score by Multidetector Computed Tomography and Plaque Components by Virtual Histology Intravascular Ultrasound

... Quantitative volumetric grey-scale and VH-IVUS analyses were performed across the entire lesion segment, and cross-sec- tional analysis was performed at the minimum lumen area sites and at the largest necrotic core ...

9

Relationship Between Intravascular Ultrasound Parameters and Fractional Flow Reserve in Intermediate Coronary Artery Stenosis of Left Anterior Descending Artery

Relationship Between Intravascular Ultrasound Parameters and Fractional Flow Reserve in Intermediate Coronary Artery Stenosis of Left Anterior Descending Artery

... SJ:Optimal intravascular ultrasound criteria and their accuracy for defining the functional significance of intermediate coronary stenoses of different ...

43

Relation between Anemia and Vulnerable Coronary Plaque Components in Patients with Acute Coronary Syndrome: Virtual Histology-Intravascular Ultrasound Analysis

Relation between Anemia and Vulnerable Coronary Plaque Components in Patients with Acute Coronary Syndrome: Virtual Histology-Intravascular Ultrasound Analysis

... Quantitative volumetric gray-scale and VH-IVUS analyses were performed across the entire lesion segment, and cross-sec- tional analyses were performed at the minimum lumen sites and at the largest NC sites. Conventional ...

7

Optimal Intravascular Ultrasound Criteria and Their Accuracy for Defining the Functional Significance of Intermediate Coronary Stenoses of Different Locations

Optimal Intravascular Ultrasound Criteria and Their Accuracy for Defining the Functional Significance of Intermediate Coronary Stenoses of Different Locations

... The 2 most frequently used in- vasive methods for coronary artery stenosis assessment are intravascular ultrasound (IVUS) and fractional flow reserve (FFR). IVUS can pro- vide accurate anatomical informa- ...

9

Relationship between Neutrophil-to-Lymphocyte Ratio and Plaque Components in Patients with Coronary Artery Disease: Virtual Histology Intravascular Ultrasound Analysis

Relationship between Neutrophil-to-Lymphocyte Ratio and Plaque Components in Patients with Coronary Artery Disease: Virtual Histology Intravascular Ultrasound Analysis

... Quantitative volumetric grey-scale and VH-IVUS analyses were performed across the entire lesion segment, and cross- sectional analysis was performed at the minimum lumen area sites and at the largest nectoric core sites. ...

7

Multi-vessel intractable coronary spasm development in a patient with aborted sudden cardiac death: a case study with intravascular ultrasound findings

Multi-vessel intractable coronary spasm development in a patient with aborted sudden cardiac death: a case study with intravascular ultrasound findings

... Sungsoo Cho, Tae Soo Kang Division of Cardiovascular Medicine, Department of Internal Medicine, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea Coronary spasm generally occurs in ...

6

A Case of In-Stent Neointimal Plaque Rupture 10 Years After Bare Metal Stent Implantation: Intravascular Ultrasound and Optical Coherence Tomographic Findings

A Case of In-Stent Neointimal Plaque Rupture 10 Years After Bare Metal Stent Implantation: Intravascular Ultrasound and Optical Coherence Tomographic Findings

... 3) Fineschi M, Carrera A, Gori T. Atheromatous degeneration of the neo- intima in a bare metal stent: intravascular ultrasound evidence. J Cardiovasc Med (Hagerstown) 2009;10:572-3. 4) Baek EK, Park SH, ...

3

Erratum: Diagnostic Performance of Intravascular Ultrasound-Derived Minimal Lumen Area to Predict Functionally Significant Non-Left Main Coronary Artery Disease: a Meta-Analysis

Erratum: Diagnostic Performance of Intravascular Ultrasound-Derived Minimal Lumen Area to Predict Functionally Significant Non-Left Main Coronary Artery Disease: a Meta-Analysis

... Jae-Sik Jang, MD, Ho-Cheol Shin, MD, Jong Seok Bae, MD, Han-Young Jin, MD, Jeong-Sook Seo, MD, Tae-Hyun Yang, MD, Dae-Kyeong Kim, MD, Kyoung-Im Cho, MD, Bo-Hyun Kim, MD, Yong Hyun Park, MD, Hyung-Gon Je, MD, and Dong-Soo ...

1

The relationship between intravascular ultrasound-derived percent total atheroma volume and fractional flow reserve in the intermediate stenosis of proximal or middle left anterior descending coronary artery

The relationship between intravascular ultrasound-derived percent total atheroma volume and fractional flow reserve in the intermediate stenosis of proximal or middle left anterior descending coronary artery

... It remains undefined whether the atherosclerotic disease extent of the conductive vessel (expressed as Intravascular ultrasound [IVUS]-derived percent total atheroma [r] ...

34

Show all 855 documents...