• 검색 결과가 없습니다.

Implant Abutment

EFFECT OF CASTING PROCEDURE ON SCREW LOOSENING OF UCLA ABUTMENT IN TWO IMPLANT-ABUTMENT CONNECTION SYSTEMS

EFFECT OF CASTING PROCEDURE ON SCREW LOOSENING OF UCLA ABUTMENT IN TWO IMPLANT-ABUTMENT CONNECTION SYSTEMS

... internal implant-abutment connection systems after casting procedure and preparation, and significantly different in internal octagonal implants (P ...

9

Correlation between microleakage and screw loosening at implant-abutment connection

Correlation between microleakage and screw loosening at implant-abutment connection

... at implant-abutment interface of implant-internal hex zirconium (I-IhZ), implant-internal hex titanium (I-IhT) and implant-morse tapered titanium (I-MTtT), a modified fluid filtration ...

4

A STUDY ON THE COMPLETE RETRIEVAL SYSTEM  OF THE CEMENTATION TYPE IMPLANT ABUTMENT

A STUDY ON THE COMPLETE RETRIEVAL SYSTEM OF THE CEMENTATION TYPE IMPLANT ABUTMENT

... 다. 9-13) 그럼에도 불구하고 최근에는 cementation type implant abutment의 사용이 증가하고 있어 ce- mentation type implant abutment system의 re- trievability에 대한 문제가 대두되었다. Retriev- ability를 확보하기 위해 임시 접착제로 합착하였을 경우, 자주 탈락되기 ...

11

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

... dental implant prostheses is caused by any of the five ...tal implant prostheses may differ depending on tightening torque, repetitive load, and the type and material of implant- abutment ...

7

IMPLANT-ABUTMENT CONNECTIONS

IMPLANT-ABUTMENT CONNECTIONS

... 골내 임플랜트의 고정체 외형은 모양이 특징적으 로 원주형태로 thread screw (Bra� nemark implant), press-fit cylinder (IMZ), hollow basket cylinder (I.T.I)등 3개의 기본형태가 이용되었다. Thread screw는 직선형, 기울어진 것, 원추형, 난원형 등으 로 구분될 수 있으며, press-fit ...

12

Three-Dimensional Finite Element Analysis for Comparison between Titanium Implant Abutment and Zirconia Implant Abutment

Three-Dimensional Finite Element Analysis for Comparison between Titanium Implant Abutment and Zirconia Implant Abutment

... 이에 본 연구에서는 삼차원적 유한요소응력분석을 이용하여 기존의 티타늄 소재의 임플란트 지대주와 지르코니아 소재의 임플란트 지대주의 응력분포비교를 통해 지르코니아 임플란트 지대주의 기계적 안정성을 간접적으로 확인하고자 하였다. 악골에 식 립된 internal conical joint type과 external butt joint ty[r] ...

11

A Finite element stress analysis of abutment screw according to the implant abutment material

A Finite element stress analysis of abutment screw according to the implant abutment material

... Fig. 3. von Mises stress distribution of abutment screw to vertical load at 10Ncm tightening torque Ⅲ. 결 과 지대주나사 대부분의 응력은 지대주와의 계면에 집중되 었으며 나사산이 시작되는 부위인 고정체와의 계면에도 나타났다. 지대주 재질에 따라 지대주나사의 von Mises 응력 값이 다르게 ...

6

Soft tissue responses to differential shapes of the implant abutment

Soft tissue responses to differential shapes of the implant abutment

... III. RESULTS Histometric analysis Due to the technically difficulty, some of the bucco-lingual sections of 12 implants re- vealed processing artifacts in the implant surface. Thus, the localization of the most ...

12

a literature review on implant abutment and soft tissue response

a literature review on implant abutment and soft tissue response

... In the implant prosthetic procedure, the soft tissue reaction was varied with the material and surface treatment of the abutment.. It may be the cause of the peri-implantitis, and hence [r] ...

11

A literature review on implant abutment and soft tissue response

A literature review on implant abutment and soft tissue response

... In the implant prosthetic procedure, the soft tissue reaction was varied with the material and surface treatment of the abutment.. It may be the cause of the peri-implantitis, and hence [r] ...

11

A Study on the heat generation during implant abutment preparation

A Study on the heat generation during implant abutment preparation

... the implant-bone interface may cause irreversible bone damage and loss of ...the implant surface caused by abutment reduction with high-speed dental turbine was ...

7

Influence of Implant Abutment Systems on Detorque Value and Screw Joint Stability

Influence of Implant Abutment Systems on Detorque Value and Screw Joint Stability

... 또한, paired t-test를 이용하여 하중 전후의 풀 림회전력을 비교하여 보았을 때 1군, 2군, 3군 각 군에 있어서 유의한 차이가 없는 것으로 조사되 었고, 제한된 조건하에서 1개월간 하중으로 인한 풀림회전력의 차이는 유의하지 않은 것으로 나 타났다. 이는 임상에서 최종 보철물이 장착된 후 1 개월 이내에 재점검을 시행하여 지대주 나사 의 풀림 현상이 나타났을 경우, 교합력이 원인일 ...

13

A finite element stress analysis on the supporting bone and abutment screw by tightening torque of dental implant abutment screw

A finite element stress analysis on the supporting bone and abutment screw by tightening torque of dental implant abutment screw

... Purpose: A study analysed the stress distribution of abutment screw and supporting bone of fixture by the tightening torque force of the abutment screw within clinical treatment situati[r] ...

7

A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment

A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment

... from implant abutments, and what effect these methods have on the retention of prosthesis during the definitive ...Forty implant fixture analogues and abutments were embedded in resin ...

7

Influence of tungsten carbide/carbon coating of  implant-abutment screw on screw loosening

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening

... 이에 본 연구에서는 external butt joint 형태를 가지는 US II 시스템과 one stage용 8도의 internal cone 연결형태의 SS II 시스템 및 11도의 internal cone 연결형태의 GS II 시스템에서 티타늄 합금 나사의 텅스텐 카바이드/탄소 코팅이 지대주 나사 풀림에 미치는 영향을 알아보기 위[r] ...

11

INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON  THE PRELOAD OF IMPLANT ABUTMENT SCREWS

INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS

... 따라서 WC/CTa 나사는 마찰계수 감소를 통한 전하 중 증가뿐만 아니라 반복체결에 따른 마찰계수의 변 화를 감소시켜 일정한 전하중을 제공할 수 있는 또 하나의 장점을 갖고 있다고 할 수 있다. 나사의 풀림 회전력은 나사의 신장과 접촉계면에 서의 마찰저항에 직접적으로 관련되어 있다. Ta 나사의 경 우에는 횟수에 따른 풀림 회전력에[r] ...

14

Influence of the implant-abutment connection design and diameter on the screw joint stability

Influence of the implant-abutment connection design and diameter on the screw joint stability

... the abutment and the fixture due to the tightening torque, increases as the tightening torque increases and the friction coefficient of the screw decreas- ...the abutment screw, or if the external load is ...

7

Implant supported over denture with O-ring abutment

Implant supported over denture with O-ring abutment

... When we make these prosthesis using O-ring, Bar, Ball attachment, we should following procedures. Strong occlusion force leads to fracture of over denture because part of functional mechanism as implant ...

8

Characteristics of Abutment Screw Structure for Dental Implant

Characteristics of Abutment Screw Structure for Dental Implant

... Fig. 1 The example for dental implant abutment fracture by screw loosening 여 치과 및 기공소에서는 시술과정에서 fig. 3 와 같이 같은 지대주 나사를 10회 정도 조였다 풀었 다를 반복하게 된다. 이는 지대주 나사의 드라이 버 체결부 Hex의 변형을 가져온다. 지대주 나사 드라이버 체결 부분인 Hex ...

8

ABUTMENT IN IMPLANT DENTISTRY

ABUTMENT IN IMPLANT DENTISTRY

... taper 연결 방식이 90。butt joint 방식보다 하중분산 에 있어서 수직력, 측방력에 대해 더욱 수직적으로 분산 가능하며, 나사연결부의 안정성과 나사 풀림이 더 적게 일어날 것이라고 보고하였다. 또한 Moller- sten 등 31) 은 연결되는 길이가 길수록 더 높은 힘에서 파절되며, conical joint는 butt [r] ...

11

Show all 1230 documents...

관련 주제