• 검색 결과가 없습니다.

Initial experience with synthetic MRI of the knee at 3T: comparison with conventional T1

N/A
N/A
Protected

Academic year: 2022

Share "Initial experience with synthetic MRI of the knee at 3T: comparison with conventional T1"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

BJR

RefeRences

1. Park S, Kwack KS, Lee YJ, Gho SM, Lee HY.

Initial experience with synthetic MRI of the knee at 3T: comparison with conventional T1 weighted imaging and T2 mapping. Br J Radiol 2017; 90: 20170350. doi: https:// doi.

org/ 10. 1259/ bjr. 20170350 2. Hagiwara A, Warntjes M,

Hori M, Andica C, Nakazawa M,

Kumamaru KK, et al. SyMRI of the brain: rapid quantification of relaxation rates and proton density, with synthetic MRI, automatic brain segmentation, and myelin measurement.

Invest Radiol 2017; 52: 647–57.

doi: https:// doi. org/ 10. 1097/ RLI.

0000000000000365

3. Del Grande F, Santini F, Herzka DA, Aro MR, Dean CW, Gold GE, et al.

Fat-suppression techniques for 3-T MR imaging of the

musculoskeletal system. Radiographics 2014; 34: 217–33. doi: https:// doi. org/ 10.

1148/ rg. 341135130 Cite this article as:

Park S, Kwack K-S. Initial experience with synthetic MRI of the knee at 3T: comparison with conventional T1 weighted imaging and T2

mapping. Br J Radiol 2018; 91: 20180006.

Received:

22 December 2017 Accepted:

03 January 2018 https:// doi. org/ 10. 1259/ bjr. 20180006

LeTTeR TO THe eDITOR

Initial experience with synthetic MRI of the knee at 3T:

comparison with conventional T 1 weighted imaging and T 2  mapping

1,2sungHOOn PaRk, MD and 1,2kyu-sung kwack, MD

1Department of Radiology, Ajou University School of Medicine, Suwon, South Korea

2Musculoskeletal Imaging Laboratory, Ajou University Medical Center, Suwon, South Korea

Address correspondence to: Kyu-Sung Kwack E-mail: xenoguma@ gmail. com, xenoguma@ ajou. ac. kr

(The Editors do not hold themselves responsible for opinions expressed by correspondents)

To the Editor,

We thank the authors for their interest and thoughtful comments on our recent paper, “Initial experience with synthetic MRI of the knee at 3T: comparison with conven- tional T1 weighted imaging and T2 mapping”,1 and appre- ciate the opportunity to address their concerns.

Our study shows that while synthetic MRI is a promising new technique used to obtain multicontrast images in a single acquisition, it has a significantly lower T2 value for bone marrow than that of multiecho spin-echo sequences without fat saturation. We agree that synthetic MRI assumes a mono-exponential decay model in that the measured relaxation rates reflect the relaxation behaviour of the dominant tissue component.2 Therefore, synthetic MRI has a limited ability to evaluate bone marrow, which undergoes multi-exponential decay.

Fat suppression is an important technique used in muscu- loskeletal imaging that improves the evaluation of bone

marrow lesions.3 Fat suppression allows the fat-associ- ated MRI signal to be removed, with minimal or no effect on the water signal. Fat suppression of bone marrow may result in a signal that more closely fits a mono-exponen- tial decay curve. The synthetic MRI technique used in our study had not been optimized to account for the inherent limitations of this method for imaging musculoskeletal tissues. Despite that synthetic MRI allowed for choice of matrix size, field of view, slice thickness, slice gap and acceleration factor, fat suppression techniques could not be applied simultaneously during image acquisition. In addition, to our knowledge, no previous reports have shown the use of fat suppression in the acquisition step of synthetic MRI.

Application of fat suppression for synthetic MRI would be very useful for quantitative assessments of bone marrow disorders. Future technical improvements, including the optimization sequences for musculoskeletal imaging, will be necessary for evaluation of bone marrow using this technique.

© 2018 The Authors. Published by the British Institute of Radiology

참조

관련 문서

It has been found that the gas velocity is a important factor to determine the value of mass transfer coefficient; the mass transfer coefficient increases with increasing

It has been found that the heat transfer coefficient has increased with increasing gas velocity, but it has exhibited a maximum value with the vari- ation of liquid velocity

Vinylphosphonates (2) which are substituted with sulfenyl group at the a-position have been used as useful synthetic reagents for the preparations of heterocyclic or

As the Secretariat indicated, it is noteworthy that most of Mexico’s trade, more specifically, (81.3% of its total trade in 2011) is with countries with which it has

As our continuous efforts to synthesize 7 and utilize 8 allenyl functionality to develop new stereoselective synthetic methods via catalysis, we became quite interested in

In comparison with optimal repair efficiency BIRA algorithms (CRESTA, SFCC), the new algorithm has a similar repair efficiency with no serious hardware cost or time cost for

The method of upper and lower solutions coupled with monotone iterative technique is used to obtain the results of existence and uniqueness for an anti-periodic boundary

In case 3, to obtain the initial planar array, a 17-element, uniformly spaced, linear array (USLA) with a half-wavelength spacing, instead of the optimized NUSLA, was extended to