• 검색 결과가 없습니다.

Panel Meters

N/A
N/A
Protected

Academic year: 2022

Share "Panel Meters"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

336

www.altronics.com.au

Pricing Levels: RRP , BULK LEVEL 1, BULK LEVEL 2 & VIP-TRADE. All pricing shown includes GST.

Components » Panel Meters

Price Each RRP 2+ 5+

Q 0490 19.50 17.55 15.60

Solder tag connections. Includes mounting parts.

SPECIFICATIONS

Backlight: 12V DC 50mA

Signal response: 0.8 seconds

Coil resistance: 650Ω

Mounting hole: 44 x 85mm

Max panel thickness: 10mm

Dimensions: 90.5W x 63.5H x 42Dmm ROHS

AmRs = Rm x At - Am - Rm V Rx = A - Rm

Price Each RRP 2 + 5+

MU45 models 17.50 15.75 14.00

MU52E models 21.95 20.75 18.45

MU45 MU52E

D C

B A

MOUNTING DETAIL Style A B C D MU45 45 4 37.5 37.5 MU52E 52 4 48 64

FS Deflection MU45 MU52E Resistance Dimensions (WxHxD) 58x52x24* 80x66x19*

1mA Q 0500A - 210Ω

1A Q 0508A - 0.0582Ω

5A Q 0510A Q 0533 0.03Ω

10A Q 0515A - 0.012Ω

20A Q 0521A - 0.004Ω

20V Q 0523A - 20kΩ

30V Q 0525A Q 0535 30kΩ

*Add 10mm depth to allow for connection terminals.

Rx +

- Rm

Voltage Multipliers Rs

+

- Rm

Current Shunt

Where...

Am = FS current of meter At = FS current required Rm = Meter resistance Rs = Required shunt

Current Shunt: Voltage Multiplier:

Where...

V = FSD voltage required A = FSD current of meter Rm = Meter resistance Rx = Required series resistor

ROHS

Price Each RRP

Q 0576 15.00

SPECIFICATIONS

Resolution 0.1°C

Range: -30°C to +70°C

Accuracy: < 40°C ±1.0°C, >40°C ±2.0°C

Sampling Rate: 10s

Indicators: Over-range, Low battery Battery: Li-Ion Cell CR-2032 Dimensions: 68.8L x 34.2W x 24Hmm ROHS

Price Each RRP

Q 0574 12.00

SPECIFICATIONS

Resolution 0.1°C

Range: -10°C to +70°C

Accuracy: < 40°C ±1.8°C, >40°C ±3.0°C

Sampling Rate: 10s

Indicators: Over-range Hi or Lo

Battery: LR44 (SR44) x 1

Dimensions: 48L x 28.6W x 15.5Hmm ROHS

Price Each RRP 2+ 5+

Q 0584 54.95 49.50 43.95

SPECIFICATIONS

Current range: 0-100A DC

Max input current: ±15mA

Power supply: 5V DC

Maximum count : 999 (3 digit)

Input impedance: 1kΩ

Sample frequency: 400ms

Dimensions: 50W x 26H x 23.5Dmm

Cutout size: 48 x 23mm

ROHS

Includes matched shunt allowing easy connection to measured power source.

Price Each RRP 2+ 5+

Q 0585 24.95 22.35 19.70

SPECIFICATIONS

Voltage range: 8-30V DC

Maximum count : 999 (3 digit)

Power supply: 8-30V DC

Sample frequency: 400ms

Dimensions: 50W x 26H x 23.5Dmm

Cutout size: 48 x 23mm

For applications requiring a professional finish and digital accuracy. Automatic zero calibration, polarity sensing and 8-30V DC powered design makes connection easy.

ROHS

Price Each RRP 2+ 5+

Q 0588 29.50 26.55 23.60

SPECIFICATIONS

Voltage range: ±199.9mV DC

Maximum count : 999 (3 digit)

Power supply: 5V DC

Sample frequency: 400ms

Dimensions: 50W x 26H x 23.5Dmm

Cutout size: 48 x 23mm

For applications requiring a professional finish and digital accuracy. Automatic zero calibration, polarity sensing and 5V DC powered design makes connection easy.

ROHS

Price Each RRP 4+ 10+

Q 0480 19.95 17.70 15.70

SPECIFICATIONS

Dimensions: 81.5L x 20W x 18H Tolerance: 0.5%

Voltage drop @ max current: 100mV

Resistance: 1mΩ ROHS

▼ Panel Meters

Panel Meters

Backlit VU Meter

Waterproof IP65 LCD Thermometer Module

LCD Thermometer Module

100A 1mΩ Meter Shunt

Digital LED Panel Mount 200mV Volt Meter Digital LED Panel Mount 8-30V DC Volt Meter Digital LED Panel Mount 0-100A Ammeter With Shunt

Price Each RRP 4+ 6+

Q 0590 49.95 44.95 39.95

Simultaneously measures voltage, current, power, charging capacity and time. The two-line LED display can display two different groups of data. The meter can switch between measurements of different parameters. It is ideal for monitoring output volt- age and current, as well as the battery charge and discharge applications.

SPECIFICATIONS

Input voltage: 0–90V (±1%)

Current: 0–20A (±2%)

Display: 4 x 8 segment LED (3 for value and 1 for unit)

Display resolution: 0.01 (all units) Units: Volts, Amps, Watts, Amp Hours, Hours Measuring rate: 5 times/s Dimensions: 79W x 43H x 25Dmm Panel cutout: 76.5W x 39.2Hmm

Voltage & Current Flush Mount Panel Meter

참조

관련 문서

this study experienced in the helicopter mode were the long delay on the ground in automatic take-off and the initial overshoot when the automatic landing was engaged. The

In the proposed approach, after the entire video sequence has been segmented into elementary content units, called shots, key frame extraction is performed by first

Modification of film structure and properties in inductively-coupled plasma (ICP) assisted dc and pulsed dc sputtering has been reported by Oya and Kusano [1] and by

Ring topology with wavelength reconfigurability makes us consider various design issues for a metropolitan WDM networks which are not expected to occur in a

청주대학교 융합전자공학부 전자공학전공 한철수.

오늘 아침, 아빠는 유리에게 윤 선생님께 사과 편지를 쓰라고 말했다.. 하지만 그것은 보통 체중 증가를 일으킨다. 만약 당신이 충분히 잠을 자지 못한다면

저의 아빠는 제가 이구아나를 도서관에 가져갔기 때문에 그것은 저의 잘못이라 고 말씀하셨습니다.. 하지만 선생님이 소리를 질러서 사람들이 여기저기로 뛰어 다녔기 때문에

Interface and Software serial RS 232; easy-link (included) Especially micro-TRI-gloss simultaneous display 2 or 3 geometries Long-term calibration with automatic check