• 검색 결과가 없습니다.

Evaluation of Glucosinolate Content and Composition Contained in Korean Leaf Mustard (Brassica juncea var. integrifolia) Germplasm Using Liquid Chromatography Electrospray Ionization Mass Spectrometry(LC-ESI-MS/MS)

N/A
N/A
Protected

Academic year: 2022

Share "Evaluation of Glucosinolate Content and Composition Contained in Korean Leaf Mustard (Brassica juncea var. integrifolia) Germplasm Using Liquid Chromatography Electrospray Ionization Mass Spectrometry(LC-ESI-MS/MS)"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

- 18 - F-O-5

Evaluation of Glucosinolate Content and Composition Contained in Korean Leaf Mustard (Brassica juncea var. integrifolia) Germplasm

Using Liquid Chromatography Electrospray Ionization Mass Spectrometry(LC-ESI-MS/MS)

Jung-Bong Kim*, Heon-Woong Kim, Ho-Cheol Ko, So-Young Kim, Se-Na Kim, Yong-Xie Jin and Jae-Hyun Kim

National Academy of Agricultural Science, RDA

Glucosinolates(GSLs) are major secondary products( -thioglucosideβ N-hydroxysulfates) containing sulfates that are found mainly in Cruciferae family such as cabbage, broccoli, radish, turnip, kale, mustard and rapeseed as the important crops in agronomic and economic aspects.

Especially, isothiocyanates(ITCs) have been shown to inhibit carcinogenesis with regulation cancer cell development followed by regulating target enzymes, inducing cell cycle arrest and apoptosis against various human cancer cell lines. Total desulfo(DS)-GSLs of nine type in 210 Korean leaf mustard accessions were isolated and confirmed using electrospray ionization mass spectrometric(ESI-MS/MS) method and DS-GSLs powerful library maked from several reference data.

The isolated individual DS-GSLs were identified by removed β-D-glucopyranose residue (C6H11O5, MW 163) from MS/MS data. Among them sinigrin(41.7%), glucoiberverin(21.7%) and gluconasturtiin(12.6%) were major components, Especially, despite gluconapin was minor component, accession K046197-1 and K046197-2 showed higher content of 4.11 and 3.31 mg/g(DW), respectively. The total GSLs contents in 210 accessions were ranged from 5.3 to 23.2 mg/g(DW) with a mean value of 13.0 mg/g(DW). As a result of principal component analysis(PCA), the individual GSLs loading plots were composed of three groups and components belonged to each group showed correlationship in quantitative pattern.

Key words : leaf mustard, glucosinolate, anti-carcinogenesis, LC-ESI-MS/MS

참조

관련 문서

The sensitivity and selectivity of the four types of coating to extract target VOCs from samples were evaluated at 10 ppbv, and the results were illustrated by plotting

A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass

An isotope dilution mass spectrometric method based on a flow-injection ESI/MS has been established and evaluated as a candidate reference method for the analysis

A headspace gas chromatographic mass spectrometric (GC-MS) assay method was developed for the simultaneous determination of methyl tertiary butyl ether (MTBE), tert-butyl

ABSTRACT − A gas chromatographic-mass spectrometric (GC-MS) method was developed for the simultaneous deter- mination of valproic acid (VPA) and its toxic metabolites,

The present study indicated that the single co- administration of KRG extract up to 2 g/kg in mice did not result in any significant herb-drug interactions linked to the

In this study, acassette assay was performed the inhibitory effects of 12 ginsenosides on seven cytochrome P450 (CYP) isoforms in human liver microsomes (HLMs) using LC-MS/MS

The typical LC-MS/MS chromatograms of PFCs obtained using MRM detection and a spiked serum sample, containing 1.0 ng mL −1 of each PFC and internal standards, are shown