포 스 터 발 표
- 고분자: 1P-156
Inorganic nanoparticles on nanopatterned surface of block copolymer
박세현⋅이종휘†⋅방준하*
중앙대학교 공과대학 화학신소재공학부, *고려대학교 공과대학 화공생명공학과 ([email protected]†)
The use of block copolymer thin films as self nanopatterned polymeric substrates has become popular as an economical nanofabrication technique, with new applications and techniques constantly being developed. There is a growing interest in the use of gold nanoparticles modified with biomolecules for the rational design of nanostructured func- tional materials and their use in electronic, optical, and biosensor applications. This study investigated the interactions between gold nanoparticles protected by polymeric electrolytes and the nanopatterened surfaces of poly (styrene-b-ethylene oxide) (PS-b-PEO).
Keywords: nanoparticles, block copolymer
- 1P-180
Exfoliated structure of thermally stable organo-clay in PET
허기영*,**⋅김대흠**⋅이상수*⋅김준경*⋅임순호*,†
*한국과학기술연구원, **광운대학교 ([email protected]†)
Nano-clay has been widely used as inorganic reinforcements for polymer matrix to cre- ate polymer nanocomposites with improved barrier, mechanical & thermal properties.
Interlayer cations (Na
+) of general organo-clay are replaced with alkyl ammonium cations to enhance the dispersibility. However, the thermal instability of alkyl ammonium cations has limitation of high processing temperature. In this work, we tried to prepare thermally stable organo-clay with alkyl imidazolium cations. Therefore, modified clay by imidazolium cations was improved thermal stability than ammonium cations. Especially, TEM images of PET-clay nanocomposites show that modified clay by imidazolium cations was more ef- fective for exfoliated structure of clay than ammonium cations.
Keywords: exfoliation, clay, thermo-stable, modification
2008 추계 학술 발표회 우수논문 발표상 수상자
- 2P-184
Preparation of electrospun nanofiber/biodegradable film from crosslinked poly(vinyl alcohol) by glyoxal
박주영⋅김맹수⋅김희선*⋅이인화†
조선대학교 환경공학과 BK21 바이오가스기반 수소생산 전문인력양성사업팀,
*조선대학교 첨단부품소재공학과 ([email protected]†)
Polyvinyl alcohol (PVA) could be cast from water as films, sheets and fibers with ex- cellent mechanical properties. PVA film and PVA fiber chemically crosslinked with glyoxal in the presence of H
3PO
4were prepared by casting/electrospinning from PVA solution.
Electrospun PVA fiber and PVA film were investigated by differential scanning calorim- etry (DSC), thermal gravity analysis (TGA). The morphology of electrospun PVA fiber was observed to field emissions scanning electron microscopy (FE-SEM). The structure of crosslinking of PVA fibers and PVA films were analyzed by infrared reflection-absorption spectroscopy (FTIR). The mechanical characteristic of crosslinked PVA film were measure by universal test machine (UTM).
Keywords: electrospinning, biodegradable film, poly(vinyl alcohol), glyoxal
- 2P-208
Star-shaped Poly(lactic acid) (PLA)의 합성과 전기방사를 이용한 나노섬유의 제조
최용재⋅손복기⋅황택성† 충남대학교 ([email protected]†)
생분해성과 생체적합성을 가지는 PLA를 star-shape으로 합성하였다. 3,4,6개의 hydroxy기 를 가지는 다가 알콜을 개시제로 하여 중축합반응 시켰으며, 합성여부를 FT-IR과 NMR을 통하여 확인하였다. GPC분석을 통해 분자량을 측정한 결과, 3-arm은 10,000~25,000, 4-arm 은 25,000~40,000, 6-arm은 20,000~35,000의 중량평균분자량을 나타내었다. 합성한 PLA를 chloroform/N,N-dimethylformamide (DMF)혼합용매를 이용하여 전기방사하였으며, 나노크 기의 직경가지는 섬유를 제조하였다. 나노섬유의 표면특성을 FE-SEM을 통해 관찰하였으며, 그 직경이 300~800 nm의 분포를 보였다. neat PLA와 star-shaped PLA의 접촉각을 측정 한 결과 star-shaped PLA 나노섬유의 접촉각이 작아졌으며, 친수화 된 것을 확인하였다.
star-shaped PLA를 이용하여 세포배양을 위한 scaffold로의 응용가능성을 확인 하였다.
Keywords: star polymer, biodegradable polymer, poly(lactic acid), electrospinning
- 나노: 2P-12
Optical Encoding method with SERS Active Nanotags (SERS dots™) in Peptide Library Synthesis
강호만⋅김종호⋅김성용⋅전봉현⋅백종호⋅김건성⋅이상명⋅박주영⋅정대홍⋅이윤식† 서울대학교
Peptide libraries play a central role in research area such as drug discovery and screen- ing for biological activity. The most powerful peptide library synthesis method is based on the combinatorial “split and mix” method with polymer beads. The biggest challenge of this process is structural identification of the interested compounds within a particular library. In this study, we designed a novel encoding method, labeling the beads by sur- face-enhanced Raman spectroscopic nanotag (SERS dots™) for easy and rapid identification. The sequence of peptides could be easily identified by the corresponding Raman bands of the SERS dots™.
Keywords: peptide library, surface enhanced Raman scattering, encoding method
- 무기재료: 2P-58
Nano particle과 macro porous nano net TiO
2의 광화학 및 광전기적 특성 비교
이선화⋅이태교⋅박노국⋅윤석훈⋅한기보⋅이태진† 영남대학교
본 연구에서는 졸-겔 법으로 합성된 TiO
2와 이들을 수열합성법으로 결정을 성장시킨 후 열 처리하여 광촉매 및 염료 감응형 태양전지의 전극으로 활용 가능한 TiO
2를 제조하였다. 또한 구형을 colloidal polystyrene latex를 메트릭스로 이용하여 macro porous한 nano net 구조를 가진 TiO
2를 제조하였다. 졸-겔 법과 수열합성법으로 합성된 TiO
2의 열처리 온도(400∼700℃) 에 따라 결정구조와 입자크기 그리고 표면적 등이 달라지며, 이들의 결정성에 따라 광화학적 혹은 광전기적 특성 또한 달라질 수 있다. 그러므로 본 연구에서는 열처리 온도에 따라 합성 된 TiO
2의 입자크기와 표면적 그리고 결정구조의 변화를 정리하고 또한 macro porous한 nano net 구조를 가진 TiO
2와 함께 광화학 및 광전기적 특성을 P25 (degussa) 분말과 비교하고자 하였다. TiO
2의 물리적 특성은 XRD, SEM, BET 등을 이용하여 분석하였으며 메틸렌 블루 광분해와 염료 감응형 태양전지의 효율을 통하여 광화학 및 광전기적 특성을 조사하였다.
Keywords: TiO
2, 졸-겔, 수열합성법, 광촉매, 염료감응형 태양전지
- 2P-56
콜로이드 용액에서의 금속 Cu 나노분말의 합성
전경민⋅김세현⋅오창섭*⋅김진배† 호서대학교 화학공학과, *KISTI
금속 Cu미립자는 적층 콘덴서, 후막 IC 콘덴서, 저온소성 다층기판, AIN 기판, 페라이트 등 전자 부품 전극소재 및 전자파 차폐제로 이용되고 있으며, 최근 전자 부품의 제조 원가를 낮추기 위한 귀금속 페이스트의 대체 재료로 많은 관심이 집중되고 있다. 본 연구에서는 구 리수용액 상태에서 직접 환원제를 첨가하여 반응시켜 Cu-colloid상태를 만들고 이를 강제 침 전시켜 100 nm 이하의 구리 나노금속분말을 제조하는 방법으로 반응조건이 생성되는 구리 입자의 형상, 크기, 입도 분포 등에 미치는 영향을 검토하였다.
Keywords: Cu-colloid, 나노금속, 구리
- 생물공학: 2P-81
The Screening of Serine Kinase by using One-Bead One-Compound (OBOC) Method
김재희⋅김은미⋅김미라⋅김윤곤⋅김병기⋅이윤식† 서울대학교
Peptides that are phosphorylated by protein kinase are widely used in drug discovery fields. To discover the specific peptide substrate sequence of protein kinase, a high- throughput screening method based on the ladder type One-Bead One-Compound (OBOC) peptide library was developed. In this study, we tried to discover the specific peptide sub- strate of protein kinase A (PKA) by using ladder type OBOC peptide library. After ana- lyzing the peptide sequences that reacted with serine kinase by using MALDI/TOF, we discovered new PKA substrate peptide sequences.
Keywords: serine kinase, OBOC, peptide library
- 석유화학윤활유: 1P-3
메조포어실리카에 고정화된 Rh 착제를 이용한 1-octene의 Hydroformylation 반응
권아영⋅전종기†⋅윤소영⋅고영수⋅배정아⋅임진형⋅송기창 공주대학교
C4 잔사유에 함유된 부텐의 고부가가치화 방법 중의 하나가 이량화 공정을 통해서 옥텐을 제조한 다음 hydroformylation 공정을 거쳐서 노닐알데히드로 전환시키는 것이다. 본 연구는 종래의 균일계 촉매로 사용되는 rhodium 착체를 나노 세공 micelle-templated silica (MTS) 에 고정화하여 불균일계 촉매화하고자 하는 것이다. MTS로는 SBA-15, MSU-H, MCM-41 를 사용하여, 나노 세공 크기 및 구조가 hydroformylation 성능에 미치는 영향과 anchoring agent의 영향을 조사하였다. 반응물은 1-옥텐을, 용매로는 Tetra hydrofuran (THF)을 사용 하였고 Ligand로는 Triphenyl phosphine (TPP)와 Triphenyl phosphine oxide (TPPO)를 사 용하였다. 1-옥텐의 hydroformylation 반응에서 SBA-15에 고정화된 로듐 착체가 가장 뛰어 난 성능을 보였으며, TPP를 Ligand로 사용하였을 때 반응 활성이 크게 증가하였다.
Keywords: Hydroformylation, octene
- 전기화학: 1P-28
Carbon nanocoating on Li(Ni
0.8Co
0.15Al
0.05)O
2cathode material for Li-ion batteries
주정훈⋅정영민⋅박유림⋅류광선† 울산대학교
We prepared the LNCA coated with carbon (LNCA/C). Several wt% series of LNCA/C were prepared by sol-gel method. We used the solid alcohol (Cetyl alcohol) as a carbon source, and treated different temperature (500∼600℃ range) at air atmosphere.
The LNCA/C is used as a cathode electrode for studying the electrochemical properties.
After assembling the coin cell, we measured the electrochemical performances. The charge-discharge curves was measured using the Maccor galvanostat and the cyclic vol- tammetry (CV) curves was measured using a macpile potentiostat. Also the A.C. im- pedance was measured using the ivium. The Field Emission scanning electron microscope (FE-SEM) was used to investigate the morphology of the samples. By using XRD, TGA, FT-IR, and etc., the chemical or physical property was analyzed.
Keywords: Cathode material, LNCA, CV, Capacity, Carbon coating, Sol-gel method
- 1P-35
Urea-formaldehyde 수지 분말을 충진제로 사용한 PVdF계 분리막의 전기화학적 특성
장재은⋅이선영⋅이진수⋅엄의흠⋅이철태† 단국대학교
분리막은 다양한 정보 통신기기의 휴대화, 소형화, 경량화에 따라 전기화학시스템의 성능 을 좌우할 중요한 요소기술로서 그 비중은 커져가고 있다. 분리막을 구성하는 기본 소재는 수지와 충진제이며 충진제의 종류 및 그 특성에 따라 분리막의 특성과 기능이 다르며 이는 전기화학시스템의 성능에 매우 중요한 영향을 미친다. 본 연구에서는 기존의 분리막의 세라 막 충진제의 약점을 보완할 수 있는 유기계 충진제로서 포름알데히드-요소수지 분말을 제조 하여 이를 PVdF수지계 분리막의 충진제로 사용한 새로운 분리막을 제조하였으며, 이를 이 용한 저기화학시스템을 구성하고 그 전기화학적 특성을 조사하여 새로운 분리막으로서 사용 가능성을 진단하였다.
Keywords: separator, polymethylene urea, electrochemical system, PVdF resin
- 접착제도료잉크: 1P-52
Synthesis and Properties of Cationic Polyurethane Dispersions Using DEAPD as Novel Cationic site
김형석*,**⋅노시태**,†⋅최근배*⋅유재철*⋅김호기*
*(주)헵스켐, **한양대학교 화학공학과 ([email protected]†)
최근 금속 코팅에서 환경적 문제로 크롬 6가의 사용이 법적으로 규제되면서, 크롬을 함유 하지 않는 양이온성 폴리우레탄 분산체가 도입된 새로운 환경친화적 금속코팅제의 개발이 증가하고 있다. 그러나 기존의 양이온성 폴리우레탄 분산체는, 양이온성을 부여하는 양이온 사이트가 폴리머의 주 체인에 존재하여 분산이 어렵고, 분산입자가 균일하지 못한 것으로 알 려져 있다. 따라서 본 연구에서는 폴리머의 주 체인에서 양이온 사이트가 일정 거리 이격된 새로운 양이온 기로서 DEAPD를 사용하여 폴리우레탄 분산체를 합성하였다. 그리고 여러 폴리올과 양이온 기의 함량이 분산 입자의 크기, 점도, 그리고 경화필름의 모폴로지와 물성 에 미치는 영향을 연구하였다.
Keywords: Polyurethane, Dispersion, Cationic
- 정보전자소재: 1P-78
RGB color electrochromic display
이지예⋅김유나⋅김은경† 연세대학교 ([email protected]†)
RGB color is very important for the color coordination in display application.
Bipyridiniums were introduced as RGB color material for the electrochromic device (ECD) fabrication. 1-methyl-4,4 '-bipyridinium iodide (MEBP), 1-(2-(2-phenylpyridinium-1-yl) ethyl)-2,2 '-bipyridin-1-ium bromide (PEBP), and 1,1'-bis(4-bromobutyl)-4,4'-bipyridinium dibromide (BBBP) successfully showed red, green, and blue (RGB) color respectively.
Elcectrochromic properties of polymer electrolyte besed ECDs were monitored using cyclic voltammetry and UV-VIS absorbance. The highest ΔABS was 0.55 and the fastest opti- cal response was measured as 1.19 sec.
Keywords: bipyridinium, electrochromic, RGB, electrochromic device
- 1P-76
Study on the pTSA/ClO
4Doped PEDOT in Organic Solvent Using a Hole Injection Layer for OLEDs
허수원⋅송인성⋅문두경† 건국대학교 ([email protected]†)
PEDOT:PSS는 OLED 및 Photovoltaic cell에 정공주입층(buffer layer)으로 사용되어 소자 의 효율을 높이는 장점을 가지고 있지만, acidic dopant인 PSS (poly(stylenesulfonate))의 작 용으로 ITO를 부식시키고 유기물층을 산화시켜 효율저하 및 수명을 단축시키는 단점도 가지 고 있다. 또한 hydrophobic한 특성을 보여 유기기판등에 적용이 어려워 organic solvent에 soluble한 buffer layer가 요구되고 있다. 따라서 본 연구에서는 PSS 대신 pTSA와 ClO4를 도핑한 organic solvent based buffer layer를 도입하여 OLED 소자를 제작하였으며, 기존의 PEDOT:PSS를 사용한 소자와 I-V-L특성, 박막특성, 광 투과도 등을 비교평가 하였다.
Keywords: OLED, Photovoltaic cell, ITO, PEDOT:PSS, pTSA/ClO
4doped PEDOT
- 촉매: 2P-115
Organo-silane Based N-Heterocyclic Carbene (NHC) Palladium Catalyst for C-C Coupling Reactions
최정우⋅윤효진⋅이윤식† 서울대학교 ([email protected]†)
Silica-supported N-heterocyclic carbene (NHC) palladium catalyst was prepared. Ionic liquid was coordinated with palladium acetate to obtain an organosilane-based bidentic NHC-Pd complex. The organosilane-based bidentic NHC-Pd complex was immobilized on silica particles by covalent bond (NHC-Pd/silica). The catalyst proved to be highly active for general C-C coupling reactions such as Suzuki, Heck and Sonogashira (Cu free) reaction. This NHC-Pd/Silica catalyst was confirmed to be an efficient catalyst for each of the reaction under mild conditions. Moreover, the catalyst could be recycled by simple filtration without significant loss of its catalytic activity.
Keywords: heterogeneous catalyst, Palladium, C-C coupling, NHC
- 2P-95
The Effect of H
2/CO ratio and Space Velocity about Product Distribution in the K/Fe-Cu-Al Catalysts for the Fischer-Tropsch Synthesis
김윤하⋅황두영⋅박은덕†⋅박명준⋅송상훈*⋅이상봉*
아주대학교, *한국화학연구원 ([email protected]†)
It was known that Fe catalysts have high activity for high temperature FTS. In this study, we prepared Fe-Cu-Al catalysts by co-precipitation method and K/Fe-Cu-Al cata- lysts by wet-impregnation method. The Fischer–Tropsch reaction has been carried out us- ing CO/H
2/Ar (29/58/13 vol%) mixture as a model in a fixed bed reactor with different temperature and pressure conditions. We found the product distribution by using Anderson-Schulz-Flory (ASF) plot. Also, increasing of H
2/CO ratio and decreasing of space velocity caused α-olefin production decreasing.
Keywords: FT, ASF, Fe, distribution
- 2P-111
Ring-Closing Metathesis (RCM) Reaction Catalyzed by Polymer Supported Ruthenium Ionic Liquid Complex
박주영⋅전봉현⋅강호만⋅이윤식† 서울대학교
Ruthenium is useful a metal catalyst for Ring-Closing Metathesis (RCM), Ring-Closing Metathesis (ROM) and Cross Metathesis (CM). However, high cost and possible con- tamination of ruthenium in the final product restrict its applications. To solve these prob- lems, we prepared reusable ruthenium catalyst through immobilization. Ruthenium was im- mobilized onto ionic liquid phase on the surface of polymer bead. In order to characterize this polymer supported catalyst, FT-IR spectroscopy, ICP-AES and FE-SEM analysis were performed. The polymer supported ruthenium ionic liquid complex was applied to RCM reaction.
Keywords: ruthenium, RCM, polymer supported catalyst
- 콜로이드계면화학: 1P-103
Ultrasmall biodegradable nanopolymersomes as effective anticancer drug carriers
이현진⋅김종득† KAIST ([email protected]†)
A series of amphiphilic graft copolymer, poly(2-hydroxyethyl L-aspartamide) (PHEA) grafted with L-lactic acid oligomers (LAs) (PHEA-g-LA) with various degree of sub- stitution (DS) of LA, was synthesized. Their self-assembled nanostructures showed struc- tural transformation from spherical micelles to ultrasmall unilamellar vesicles according to the increase of DS. By differing of the aggregate preparation method, the vesicles of dif- ferent size, ultrasamll nanovesicles less than 50 nm, nanovesicles about 150 nm, and micro- vesicles about 5 µm in diameter, were prepared. Vesicles loaded with hydrophilic anti- cancer drug doxorubicin⋅hydrochloride were prepared and in vitro loading and release be- havior was monitored. They showed effective intracellular delivery and therapeutic effect in the in vitro cell study.
Keywords: polymersome, biodegradable, drug carrier
- 펄프제지피혁: 1P-111
지류포장재 내 중금속 함량 분석을 위한 최적의 산 분해 조건 탐색
이태주⋅김형진†⋅고승태 국민대학교 ([email protected]†)
시료 내의 중금속 함량은 산을 이용한 습식분해 전처리와 이 과정을 통해 분리된 금속 이 온을 ICP (Inductively Coupled Plasma)를 이용한 방출분광법을 통하여 이루어지고 있다. 그 러나 수용액 내의 중금속 원소들은 분해 산에서 유도된 비금속 성분들과 반응하여 산화물 또는 수산화물 형태로 변화하고 이로 인한 소실을 유도함으로써 정확한 중금속의 정량적 분 석이 어렵게 되는 경우가 발생한다. 따라서 본 연구에서는 지류 포장재 내의 최적 분석 기법 탐색을 위하여 open system 하에서 산 조성에 따른 회수율을 측정함으로써 정확한 중금속 정량 방법을 위한 기초자료를 얻고자 하였다.
Keywords: packaging paper, heavy metal content, open digestion, mixed acid
- 화학공정: 1P-130
Solubility Prediction of bio-antioxidant by Group contribution correlation
최인창⋅송유정⋅이은지⋅정구형⋅홍인권† 단국대학교
The body is aged by lipid peroxide oxidised with active oxygen. Bio-antioxidant pre- vents damaging and ageing our body from the active oxygen. A sort of bio-antioxidants is epicatechin, bisphenol A, ascorbic acid and so on. In this study, we selected the optimum solvent that can solvate well each bio-antioxidant by calculating the solubility of various antioxidant for each solvent. The solubility parameters of bio-antioxidant are correlated with van-Krevelen group model, then the solubility of bio-antioxidant for each solvent was calculated by interaction relationship between each solubility parameter of bio-antioxidant and selected solvent.
Keywords: Bio-antioxidant, solubility parameter, group contribution
- 1P-137
Drug Release Characteristics of Flurbiprofen from a Chitosan Bead
민병준*,†⋅김태영*⋅주숙**⋅양재호**⋅김승재*,***⋅조성용*
*전남대학교 환경공학과, **전남대학교 응용화학공학부, ***환경연구소 ([email protected]†)
Drug delivery system (DDS) using the chitosan beads has been investigated. The drug release behavior from chitosan beads loaded flurbiprofen was studied in terms of various conditions. Chitosan beads were prepared through the ionic cross-linking between chitosan and sodium tripolyphosphate (TPP). The experiments of drug release from chitosan bead were performed in phosphate buffer solution (PBS). The amount of released drug of flur- biprofen was analyzed by UV spectrophotometer at 247 nm. The loading efficiency of flurbiprofen increased with increasing concentration of TTP solution. Due to high loading efficiency and easiness of drug release control, chitosan beads could be used as a potential delivery system to control the release of drug.
Keywords: chitosan bead, drug, flurbiprofen
- 환경에너지: 1P-261
연속식 관형 전기분해반응조를 이용한 하수 중 인 제거 특성
윤용수†⋅브이홍하⋅박민정⋅양하늘⋅김사동*
단국대학교 화학공학과, *(주)젠트로 ([email protected]†)
하수고도처리를 위하여 알루미늄 연속식 관형 반응기를 이용하여 인을 제거하기 위하여 유입하수 중의 COD, SS 농도, 전해질 농도, 관형반응기에서의 유속(유량) 등이 전해응집에 의한 인 제거율에 미치는 영향과 전해산화에 의한 COD 감소효과에 대하여 검토함으로써 연 속식 관형 전기분해 반응조를 이용한 인 제거기술의 상용화 가능성에 대하여 조사하고자 하 였다.
Keywords: Electrochemical P-removal, Advanced treatment of sewage
- 1P-274
Demixing Reagents 첨가에 따른 PSF Microfiltration Membrane의 비대칭 구조에 관한 연구
최동호⋅김청숙⋅김노원† 동의대학교 환경공학과 ([email protected]†)
상 전이 공정에 의해 제조되는 수처리용 고분자 분리막은 높은 유량과 입자 크기에 따른 투과 선택성이 우수한 특징을 가지고 있어 정밀여과 및 한외여과 공정에 있어 널리 적용되 고 있다. 상 전이 공정에 있어 고분자 분리막의 형성 여부는 주로 상 전이 평형인자인 고분 자 용액의 조성, 치환 용매의 조성, 상전이 온도에 의해 결정되어지나 투과 성능은 hydro- philic polymer, non-solvent, humidity, demixing reagent 등의 첨가에 따라 조절 가능하다.
본 연구에서는 상 전이 과정에서 steric hindrance가 각각 달리 작용할 수 있는 demixing re- agent를 첨가하여 멤브레인의 비대칭성 구조에 대한 조절이 가능함을 확인하였고 이에 따른 투과 성능 변화, 구조 변화, pore size 분포 변화를 살펴보았다.
Keywords: Demixing Reagents, polysulfone, microfiltration membrane, asymmetric mem- brane
- 2P-253
가시광 영역에서 광촉매(TiO
2)를 이용한 가스상 원소수은의 제거메커니즘 규명
엄유진⋅전석호⋅이태규† 연세대학교 ([email protected]†)
TiO
2의 밴드 갭(band gap) 에너지는 Antase 결정상은 3.22 eV, Rutile 결정상은 3.00 eV 으로 밴드 갭보가 크거나 비슷한 에너지를 가진 자외선을 조사하면 전자(e-)와 정공(hole, h+) 쌍이 형성되어 광활성을 가진다. 최근에는 무한한 에너지인 태양광 또는 가시광 조사하 에서 활성을 가지는 TiO
2개발이 활발히 진행중이다. 본 연구팀은 가시광 조사하에서 TiO
2(P25, anatase:rutile = 80:20, Degussa, Germany)을 이용하여 가스상 원소수은의 제거 실험 결과, 제거효율이 자외선 조사시와 거의 동일하게 나타남을 발표한 바 있다(Lee et al ., 2004). 본 연구는 제거메커님즘 규명을 위하여 가스상 원소수은 제거 실험 전후의 TiO
2촉매 의 표면 분석(X-ray photoelectron spectra, UV-visible diffuse reflection spectra) 및 열중량 분석(Thermogravimetric analysis) 등을 실시하였으며, 흡수스펙트럼의 측정 결과 400∼500 nm 영역에서 가시광 흡수밴드가 나타남을 확인하였다.
Keywords: 광촉매, 원소수은, 가시광
- 2P-238
PVDF/PDMS 복합막의 제조와 투과증발을 이용한 n-부탄올/물 분리 및 농축
지기용⋅전은주⋅김노원*⋅이용택† 경희대학교 화학공학과, *동의대학교 환경공학과