Implementation Test of Two-dosimeter Algorithm for More Precisely Estimating Effective

Dose during Maintenance Periods at KNPPs

H. G. Kim,a G. Park,a T. Y. Kong,a Y. H. Yang,a D. W. Kang,a S. N. Seo,b B. C. Lim,b and S. C. Park b

a KEPRI, 103-16, Munji-Dong, Yuseong-Gu, Daejeon, 305-380, Republic of Korea, hkkim@kepri.re.kr b KHNP, 167, Samsong-Dong, Seoul, 135-791, Republic of Korea

1. Introduction

The application of a two-dosimeter and its algorithm and a test of its use in an inhomogeneous high radiation field is described. The goal was to develop an improved method for estimating the effective dose during maintenance periods at Korean nuclear power plants (NPPs). The use of the method in domestic and international NPPs including USA, Canada and Japan was also investigated. The algorithms used by the Canadian Ontario Power Generation (OPG) [1] and American ANSI HPS N13.41 [2], Lakshmanan [3], NCRP [4], EPRI [5] and Texas A&M University [6,7,8] were extensively analyzed as two-dosimeter algorithms. The possibility of their application to NPPs was evaluated using data for each algorithm from two-dosimeter results for an inhomogeneous high radiation field during maintenance periods at Korean NPPs.

2. Methods and Results

In Korean NPPs, two additional dosimeters (TLD) are provided before the start of high radiation work and the maximum measured value of the dosimeter is selected as the effective dose value; however, this value is overestimated by approximately 10 to 50 percent. Three additional dosimeters, on the other hand, provided to radiation workers who wear them on the head, chest and back, simultaneously, and the measured values are analyzed for the purpose of adopting a two-dosimeter algorithm for Korean NPPs among several algorithms during the maintenance periods.

0 1 2 3 4 5 6 0 5 10 15 20 25 30 TLD User

Effective dose equivalent, H

E (mSv) Canada(ICRP-60) ANSI NCRP(70/30) NCRP(55/50) EPRI(Xu) Lakshmanan Kim

Installation of S/G Nozzle Dam (#4-7th)

Figure 1. Application of two-dosimeter algorithm for the installation of S/G nozzle dam (#4-7th) at Yonggwang NPPs no. 2 0 1 2 3 4 5 6 0 5 10 15 20 TLD User Ef fect

ive dose equivalent

, H E (mSv) Canada(ICRP-60) ANSI NCRP(70/30) NCRP(55/50) EPRI(Xu) Lakshmanan Kim

Removal of S/G Nozzle Dam (#4-7th)

Figure 2. Application of two-dosimeter algorithm for the removal of S/G nozzle dam (#4-7th) at Yonggwang NPPs no. 2

The results indicate that the algorithms of OPG, ANSI, NCRP, EPRI (NRC) and Texas A&M University show the almost the same tendency without Lakshmanan's algorithm. Thus, there is no problem in applying any of the above algorithms without Lakshmanan to Korean NPPs in an inhomogeneous high radiation field and the current multi-TLD radiation dosimetry could be improved, if it were to be applied.

3. Conclusion

In this study, the NCRP (55/50) algorithm of the National Council on Radiation Protection and Measurements (NCRP) was adopted because of its reliability and for technical reasons. Hence, a method in which two TLD dosimeters are worn on the chest and back, will be used for radiation workers instead of wearing an TLD at the head and chest. In addition, the two-dosimeter condition is based on the INPO 91-014 guideline and will be modified with regard to radiation exposure limits and distributed to Korean radiation workers at NPPs.

REFERENCES

[1] Ontario Power Generation (formerly Ontario Hydro Nuclear), Ontario Hydro Radiation Protection Dosimetry

Programme, IR-11 (Revision 2), 1992.

[2] American National Standards Institute (ANSI), An

American National Standard Criteria for Performing Multiple Dosimetry, Report No. HPS N13.41, 1997.

[3] A. R. Lakshmanan, R. K. Kher, S. J. Supe, Estimation of Effective Dose Equivalent Using Individual Dosemeters, Radat. Prot. Dosim. Vol. 35, No. 4, pp. 247-252, 1991.

Transactions of the Korean Nuclear Society Autumn Meeting Busan, Korea, October 27-28, 2005

(2)

[4] National Council on Radiation Protection and Measurements (NCRP), Use of Personal Monitors to Estimate

Effective Dose Equivalent and Dose to Workers for External Exposure to Low-LET Radiation, NCRP Report No.122,

Bethesda, 1995.

[5] United States Nuclear Regulatory Commission (USNRC), NRC Regulatory NRC Regulatory Issue Summary 2004-01,

Method for Estimating Effective Dose Equivalent from External Radiation Sources Using Two Dosimeters, Report

No. RIS 2004-01, 2004.

[6] X. G. Xu, W. D. Reece, and J. W. Poston, A Study of the Angular Dependence Problem in Effective Dose Equivalent Assessment, Health Physics, Vol. 68, No. 2, pp. 214-224, 1995.

[7] C. H. Kim, Use of Two Dosimeters for Better Estimation of Effective Dose. College Station, TX: Texas A&M University, 1998.

[8] C. H. Kim, W. D. Reece, and J. W. Poston, Development of a Two-dosimeter Algorithm for Better Estimation of Effective Dose Equivalent and Effective Dose, Radat. Prot. Dosim. Vol. 81, No. 2, pp. 101-112, 1999.

수치

Figure 2. Application of two-dosimeter algorithm for the  removal of S/G nozzle dam (#4-7th) at Yonggwang NPPs no

참조

관련 문서

results of a phase II study of high-dose radiation therapy and neoadjuvant plus concomitant 5-fluorouracil with CDDP chemotherapy for patients with anal

The stability of traveling wave solutions for evolution equations of order higher than two had been dealt with by using an extended variational approach which was matched to

Committee for Energy Conservation (NCEC) to improve implementation of energy efficiency and conservation policies for each energy-using sector. This means that an

In this thesis, experimentally evaluated the characteristics of MOSFET dosimeter for reproducibility, linearity, isotropy, dose rate dependence and verification

Equivalent dose (HT) to tissues/organs in the maxillofacial region and effective doses for indirect and direct digital panoramic radiographys... Comparison of effective

An efficient algorithm for mining association rules in large databases. An effective hash-based algorithm for

In the analysis of the dose constraint of nuclear medical radiation workers using chi-square test statistics, the dose constraint at (the time of) the highest

Therefore, as a recovery method during exercise, it is more effective for recovery of exercise fatigue and prevention of body acidification due to high