Development of a Plattform for Body Temperature Management Using Contactless Infrared Temperature Sensor and nRF52832

N/A
N/A
Protected

Academic year: 2021

Share "Development of a Plattform for Body Temperature Management Using Contactless Infrared Temperature Sensor and nRF52832"

Copied!
3
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

2020 ·

nRF52832

,

,

,

,

,

[email protected], [email protected], [email protected],

[email protected], [email protected], [email protected]

Development of a Plattform for Body Temperature Management Using

Contactless Infrared Temperature Sensor and nRF52832

Gyeol Kim, Jong Hyun Lee, Juhwan Jang, Hyuk In Kwon, Hyeongseok Kim, Jeongchang

Kim

Korea Maritime and Ocean University

nRF52832 . , . , . , . , QR . .

1.

, . , , . , IoT(Internet of Things) , IoT

. [1] , [2] . , , (body temperature) (hardware) (software) (platform) .

2.

1 . (Bluetooth) (microprocessor) . 309

(2)

2020 · 1. QR . QR . , , nRF52832 . , nRF52832 BLE(Bluetooth low energy)

. . , , . , . 2 Melexis MLX90614 Standard accuracy Medical accuracy

. 그림 2. 적외선 온도 센서 (MLX90614) 30cm~60cm , ±0.5 ˚C . 16 , ( *0.02)-273.15= (˚C) . [3] , , , , TWI

(two wire interface) . Nordic nRF52832 . nRF52832 ARM Cortex-M4F , 5.0 . nRF52832 1 . 1. nRF52832 Item Specification

Processor 32-bit ARM Cortex M4F Interface SPI, TWI, UART, PDM, I2S Bluetooth Bluetooth 5.0 Supply Voltage 1.7V ~ 3.6V 3 , 3(a) 3(d) , , , . (a) (b) 310

(3)

2020 · (c) (d) 3. , (a) , (b) , (c) , (d)

3.

nRF52832 . , . QR , . ACKNOWLEDGMENT ( ) (LINC+) . [1] “ : ”, , Vol. 26, No. 6,pp 668-680, 2014 [2] , “ ”, Vol. 24, No. 9, 2007 [3] , “ ˑ ”, , Vol. 2, No. 3, 1995 311

참조

관련 문서

This study reports sensitivity enhancement method of a temperature sensor based on fiber Bragg grating (FBG) in combination with an auxiliary materials with a

A Study on the Temperature Dependent for Reliability Improvement of SMPS for LED Lamp.. 2017

The materials used for this research are the average temperature, maximum temperature, minimum temperature, precipitation, humidity, and sunshine duration in Honam

34 Comparison of temperature histories for FSW welded joints with travel speed in different rotation speeds · · · ·58 Fig.. 35 Comparison of temperature values for

▪ Local temperature of PMSM can be calculated through thermal resistance model and heat generation model, presenting the cooling performance thermal

Development of Low - Temperature Fuel Performance Analysis Code for Micro Ultra Long Life Lead - cooled Fast Reactor. Ji Won Mun and

Express the

pottery, tableware, cookware, building materials, aerospace materials, to nuclear materials (e.g., UO 2 pellets, waste forms, etc.)... A’ a’ B’ b’ C’