• 검색 결과가 없습니다.

Rigidfix 와 Infrafix 로 고정한 슬괵건을 이용한 전방 십자인대 재건술 후 경골터널의 확장

N/A
N/A
Protected

Academic year: 2021

Share "Rigidfix 와 Infrafix 로 고정한 슬괵건을 이용한 전방 십자인대 재건술 후 경골터널의 확장"

Copied!
1
0
0

로드 중.... (전체 텍스트 보기)

전체 글

(1)

Rigidfix 와 Infrafix 로 고정한 슬괵건을 이용한

전방 십자인대 재건술 후 경골터널의 확장

Department of Orthopaedic Surgery, Eulji Medical Center, Seoul, Korea

Nam-Hong Choi, M.D., and Yoo-Hoon Jung, M.D.

The purpose of this study was to evaluate tibial tunnel widening prospectively after anterior cruciate ligament (ACL) reconstruction with hamstring tendon grafts using Rigidfix (DePuy Mitek, Raynham, MA) femoral fixation and Intrafix (DePuy Mitek) tibial fixation. 56 consecutive patients who underwent ACL reconstruction with a minimum of 2 years’postoperative evaluation were reviewed. On the anterior-posterior (AP) and lateral radiographs, the diameter of the tibial tunnel was measured at proximal, middle, and distal positions and the shape of the tibial tunnels were classified. Tunnel widening was defined as widening of greater than 2 mm. Group I was defined as cases with no tunnel widening and group II defined as cases with tunnel widening. Postoperative laxity evaluations were performed using Lachman test, pivot-shift test, and Instrumented laxity testing using the KT-1000 arthrometer. On the AP radiographs, the average diameter of the tibial tunnel increased 8.8% at 6 months and 8.5% at 12 months postoperatively compared to the immediate postoperative day. On the lateral radiographs, the average diameter of the tibial tunnel increased 7.2% at 6 months and 8.1% at 12 months year postoperatively compared to the immediate postoperative day. The tunnel shape evaluation revealed predominantly linear type in 53 patients (95%). Group I was 42 patients (75%) and group II was 14 (25%). The average KT-1000 measurement was 1.0~1.8 mm in group I and 2.1~2.8 mm in group II (p>0.05) The Lachman and pivot-shift showed tests no significant differences between the two groups. In conclusion, hamstring ACL reconstruction using Rigidfix and Intrafix fixation showed less widening of the tibial tunnels than observed in previously published studies.

– 153 –

참조

관련 문서

The purpose of this study is to use Lucia jig, leaf gauge, and cotton roll among the anterior deprogramming devices being used to induce the centric

The purposes of the present study are to evaluate the clinical outcomes and radiological outcomes including bone fusion and subsidence that occurred after

The purpose of this study was to evaluate surface changes and abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and

The purpose of this study was to propose the instructional strategies for teaching three-dimensional geometry to students with visual impairments by

The purpose of this study was to examine the effect of shadowing using English movies on listening and speaking skills, learning interest, and attitudes

The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods.. Zirconia coping was made

This research is that students who was registered athlete students after anterior cruciate ligament reconstruction , among students, 5 students quited

The purpose of this study was to evaluate the microleakage of composite resins(Filtek ™ Z250), resin-reinforced glass ionomer cements (Fuji II LC ® ), and traditional